MY2IN-D2-GS DC12 Equivalent & Substitute Parts

Part Overview

The MY2IN-D2-GS DC12 is a general purpose relay manufactured by Omron Automation and Safety with a 12VDC coil. This component is classified as Obsolete, making identification of suitable substitute parts essential for ongoing system maintenance and new design implementations. The relay serves as a switching element in control circuits requiring DPDT (2 Form C) contact configuration with 10A contact rating capability.

Substiute Parts

MY2IN-D2-GS DC12
Omron Automation and SafetyIn Stock: 1146MY2IN-D2-GS DC12 Datasheet
MY2IN-D2-GS DC12
Current Part
MY2IN-D2-GS-R DC12
Omron Automation and SafetyIn Stock: 864MY2IN-D2-GS-R DC12 Datasheet
MY2IN-D2-GS-R DC12
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number MY2IN-D2-GS DC12
Manufacturer Omron Automation and Safety
Description RELAY GEN PURPOSE
Product Status Obsolete
Base Product Number MY2IN
Coil Voltage 12VDC
Contact Form DPDT (2 Form C)
Contact Rating (Current) 10 A

Substitute Part Grouping Explanation

Substitution of the MY2IN-D2-GS DC12 is determined by the following critical parameters:

  • Coil Voltage: 12VDC (exact match required)
  • Contact Form: DPDT (2 Form C) (exact match required)
  • Contact Rating (Current): 10 A (minimum requirement)
  • Relay Type: General Purpose
  • Manufacturer: Omron Automation and Safety (same manufacturer line)
  • Base Product Number: MY2IN (same product family)

The substitute part MY2IN-D2-GS-R DC12 maintains all critical electrical parameters while offering an Active product status, making it the direct replacement for the obsolete MY2IN-D2-GS DC12.

Parameter Comparison

Parameter MY2IN-D2-GS DC12 (Main Part) MY2IN-D2-GS-R DC12 (Substitute)
Manufacturer Omron Automation and Safety Omron Automation and Safety
Product Status Obsolete Active
Base Product Number MY2IN MY2IN
Coil Voltage 12VDC 12VDC
Contact Form DPDT (2 Form C) DPDT (2 Form C)
Contact Rating (Current) 10 A 10 A
Switching Voltage Not specified 250VAC, 220VDC - Max
Coil Current Not specified 75 mA
Coil Type Not specified Non Latching
Features Not specified Diode, Lighted Indicator, Mechanical Indicator
Termination Style Not specified Plug In, Quick Connect - 0.110" (2.8mm)
Must Operate Voltage Not specified 9.6 VDC
Must Release Voltage Not specified 1.2 VDC
Operate Time Not specified 20 ms
Release Time Not specified 20 ms
Operating Temperature Not specified -40°C ~ 70°C
Contact Material Not specified Silver (Ag)
Coil Resistance Not specified 160 Ohms
Mounting Type Not specified Socketable

Engineering Selection Recommendations

The MY2IN-D2-GS-R DC12 is the direct substitute for the obsolete MY2IN-D2-GS DC12. Both components share identical electrical specifications for coil voltage (12VDC), contact configuration (DPDT 2 Form C), and current rating (10A). The substitute part carries Active product status from Omron Automation and Safety, ensuring continued availability and manufacturing support.

Selection of the MY2IN-D2-GS-R DC12 is appropriate for applications requiring replacement of the obsolete MY2IN-D2-GS DC12 without circuit redesign, provided the mounting interface (Socketable) and termination style (Plug In, Quick Connect - 0.110") are compatible with existing installations.

Frequently Asked Questions (FAQ)

Q: Can MY2IN-D2-GS-R DC12 directly replace MY2IN-D2-GS DC12?

A: Yes. Both parts share identical coil voltage (12VDC), contact form (DPDT 2 Form C), and contact rating (10A). The substitute is manufactured by the same supplier and maintains the same base product number (MY2IN).

Q: What is the primary reason for substitution?

A: The MY2IN-D2-GS DC12 is classified as Obsolete. The MY2IN-D2-GS-R DC12 is an Active product from the same manufacturer and product family, ensuring continued supply and support.

Q: Are there mechanical compatibility considerations?

A: The MY2IN-D2-GS-R DC12 features Socketable mounting with Plug In, Quick Connect termination (0.110" / 2.8mm). Verify that existing socket interfaces and termination connections match these specifications before installation.

Q: What are the operating voltage limits for the substitute part?

A: The MY2IN-D2-GS-R DC12 must operate at a minimum of 9.6 VDC and must release at 1.2 VDC maximum. Standard 12VDC supply voltage falls within the normal operating range.

Q: Are there additional features in the substitute part?

A: The MY2IN-D2-GS-R DC12 includes Diode, Lighted Indicator, and Mechanical Indicator features. These additions do not affect substitution compatibility but may provide enhanced functionality in control circuit applications.

Request Quote (Ships tomorrow)