Part Overview
The Omron MY2-GS AC220/240 is a general purpose relay with DPDT (2 Form C) contact configuration, rated for 5A at 240VAC. This socketable relay features a mechanical indicator and is designed for non-latching applications with 240VAC coil voltage. The MY2-GS AC220/240 is classified as obsolete, making identification of suitable substitute parts essential for ongoing system maintenance and new design implementations where this relay type is specified.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | MY2-GS AC220/240 |
| Manufacturer | Omron Automation and Safety |
| Series | MY |
| Product Status | Obsolete |
| Coil Voltage | 240VAC |
| Contact Form | DPDT (2 Form C) |
| Contact Rating (Current) | 5 A |
| Switching Voltage | 250VAC, 220VDC - Max |
| Mounting Type | Socketable |
| Termination Style | Plug In |
| Operating Temperature Range | -55°C ~ 70°C |
| Contact Material | Silver (Ag) |
| RoHS Status | RoHS Compliant |
Substitute Part Grouping Explanation
Substitution of the MY2-GS AC220/240 is determined by the following critical parameters:
- Coil Voltage: Must be 240VAC to maintain direct compatibility with existing control circuits
- Contact Form: Must remain DPDT (2 Form C) to preserve switching functionality
- Mounting Type: Must be socketable to fit existing relay sockets
- Termination Style: Must support plug-in connection for direct socket compatibility
- Operating Temperature Range: Must encompass -55°C ~ 70°C minimum
- Contact Material: Silver (Ag) contact material ensures consistent switching performance
- Coil Type: Must be non-latching for equivalent operational behavior
The MY2-GS-R AC220/240 meets all these critical substitution criteria while offering enhanced contact rating and improved product status.
Parameter Comparison
| Parameter | MY2-GS AC220/240 (Main Part) | MY2-GS-R AC220/240 (Substitute) |
|---|---|---|
| Manufacturer | Omron Automation and Safety | Omron Automation and Safety |
| Coil Voltage | 240VAC | 240VAC |
| Contact Form | DPDT (2 Form C) | DPDT (2 Form C) |
| Contact Rating (Current) | 5 A | 10 A |
| Switching Voltage | 250VAC, 220VDC - Max | 250VAC, 220VDC - Max |
| Coil Current | 4.3 mA | 4.3 mA |
| Coil Type | Non Latching | Non Latching |
| Features | Mechanical Indicator | Mechanical Indicator |
| Mounting Type | Socketable | Socketable |
| Termination Style | Plug In | Plug In, Quick Connect - 0.110" (2.8mm) |
| Must Operate Voltage | 192 VAC | 192 VAC |
| Must Release Voltage | 72 VAC | 72 VAC |
| Operate Time | 20 ms | 20 ms |
| Release Time | 20 ms | 20 ms |
| Operating Temperature | -55°C ~ 70°C | -55°C ~ 70°C |
| Contact Material | Silver (Ag) | Silver (Ag) |
| Coil Resistance | 15.92 kOhms | 15.92 kOhms |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
Engineering Selection Recommendations
The MY2-GS-R AC220/240 is the direct manufacturer-recommended substitute for the obsolete MY2-GS AC220/240. Both relays share identical coil voltage, contact form, switching characteristics, and operating parameters. The MY2-GS-R AC220/240 maintains active product status with ROHS3 compliance, ensuring long-term availability and regulatory alignment. The increased contact rating of 10A in the substitute part provides additional design margin while maintaining full backward compatibility with existing socketable installations. The enhanced termination options in the MY2-GS-R AC220/240 (Quick Connect capability) offer installation flexibility without compromising the standard plug-in connection method.
Frequently Asked Questions (FAQ)
Q: Can the MY2-GS-R AC220/240 directly replace the MY2-GS AC220/240 in existing installations?
A: Yes. Both relays are socketable with identical plug-in termination, matching coil voltage (240VAC), identical contact form (DPDT), and equivalent operating characteristics. The MY2-GS-R AC220/240 fits directly into existing MY2-GS AC220/240 relay sockets.
Q: What is the significance of the higher 10A contact rating in the MY2-GS-R AC220/240 compared to the 5A rating of the original?
A: The MY2-GS-R AC220/240 provides a 10A contact rating versus the original 5A rating. This represents a design enhancement that maintains full compatibility while offering increased current-switching capacity. Applications originally designed for 5A operation remain fully supported.
Q: Are there packaging differences between these two relays?
A: The MY2-GS AC220/240 is packaged in standard format, while the MY2-GS-R AC220/240 is supplied in bulk packaging. Both maintain identical socketable form factors and plug-in termination for relay socket compatibility.
Q: What compliance certifications apply to the substitute part?
A: The MY2-GS-R AC220/240 carries ROHS3 compliance certification and is REACH unaffected, meeting current regulatory requirements for electronic components in industrial applications.
Q: Are the coil operating parameters identical between the two relays?
A: Yes. Both relays share identical coil voltage (240VAC), coil current (4.3 mA), coil resistance (15.92 kOhms), must-operate voltage (192 VAC), must-release voltage (72 VAC), and response times (20 ms operate and release). The relays are functionally equivalent in coil performance.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts