MPXV5004GVP Equivalent & Substitute Parts

Part Overview

The MPXV5004GVP is a vented gauge pressure sensor manufactured by NXP Semiconductors, designed for board mount applications with analog voltage output. This component operates within a 0.57 PSI (3.92 kPa) pressure range and delivers output signals between 1 V and 4.9 V. The product is currently classified as obsolete, making identification of suitable substitute components essential for ongoing system support and new design implementations.

Substiute Parts

MPXV5004GVP
NXP SemiconductorsIn Stock: 1540MPXV5004GVP Datasheet
MPXV5004GVP
Current Part
MPXV5004DP
NXP USA Inc.In Stock: 100419MPXV5004DP Datasheet
MPXV5004DP
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number MPXV5004GVP
Manufacturer NXP Semiconductors
Series MPXV5004
Product Status Obsolete
Pressure Type Vented Gauge
Operating Pressure 0.57 PSI (3.92 kPa)
Output Type Analog Voltage
Output Range 1 V ~ 4.9 V
Supply Voltage 4.75 V ~ 5.25 V
Port Size Male - 0.13" (3.3 mm) Tube
Port Style Barbed
Maximum Pressure 2.32 PSI (16 kPa)
Operating Temperature 0°C ~ 85°C
Mounting Type Surface Mount
Package / Case 8-SMD Module
Termination Style SMD (SMT) Tab
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the MPXV5004GVP is determined by the following critical parameters:

  • Operating pressure range: 0.57 PSI (3.92 kPa)
  • Output voltage range: 1 V ~ 4.9 V
  • Supply voltage: 4.75 V ~ 5.25 V
  • Maximum pressure rating: 2.32 PSI (16 kPa)
  • Operating temperature range: 0°C ~ 85°C
  • Port size and style: Male - 0.13" (3.3 mm) Tube, Barbed
  • Mounting type: Surface Mount
  • Series compatibility: MPXV5004

The MPXV5004DP shares the same base product number (MPXV5004), operating pressure, output voltage range, supply voltage, maximum pressure rating, operating temperature range, port size, and mounting type. However, the MPXV5004DP differs in pressure type (differential versus vented gauge) and termination style (gull wing versus SMD tab), which represent functional and mechanical distinctions that must be evaluated against application requirements.

Parameter Comparison

Parameter MPXV5004GVP MPXV5004DP
Manufacturer NXP Semiconductors NXP USA Inc.
Series MPXV5004 MPXV5004
Product Status Obsolete Active
Pressure Type Vented Gauge Differential
Operating Pressure 0.57 PSI (3.92 kPa) 0.57 PSI (3.92 kPa)
Output Type Analog Voltage Analog Voltage
Output Range 1 V ~ 4.9 V 1 V ~ 4.9 V
Supply Voltage 4.75 V ~ 5.25 V 4.75 V ~ 5.25 V
Port Size Male - 0.13" (3.3 mm) Tube Male - 0.13" (3.3 mm) Tube, Dual
Port Style Barbed Barbed
Maximum Pressure 2.32 PSI (16 kPa) 2.32 PSI (16 kPa)
Operating Temperature 0°C ~ 85°C 0°C ~ 85°C
Mounting Type Surface Mount Surface Mount
Termination Style SMD (SMT) Tab Gull Wing
Package / Case 8-SMD Module 8-BSOP (0.475", 12.06 mm Width) Dual Ports, Same Side
RoHS Status ROHS3 Compliant ROHS3 Compliant

Engineering Selection Recommendations

The MPXV5004DP is an active product within the MPXV5004 series and maintains compliance with ROHS3 standards. As the MPXV5004GVP is obsolete, the MPXV5004DP represents the current manufacturing alternative from NXP USA Inc.

Selection of the MPXV5004DP requires evaluation of the following functional differences:

  • Pressure measurement type: The MPXV5004GVP measures vented gauge pressure (referenced to atmospheric pressure through a vent), while the MPXV5004DP measures differential pressure (referenced between two independent pressure ports).
  • Port configuration: The MPXV5004GVP features a single male barbed port, while the MPXV5004DP features dual male barbed ports on the same side.
  • Termination and packaging: The MPXV5004GVP uses SMD tab termination in an 8-SMD module package, while the MPXV5004DP uses gull wing termination in an 8-BSOP package.

These differences necessitate circuit board redesign and application-level validation to ensure functional compatibility.

Frequently Asked Questions (FAQ)

Q: Can the MPXV5004DP directly replace the MPXV5004GVP without circuit modifications?

A: No. The MPXV5004DP differs in pressure measurement type (differential versus vented gauge), port configuration (dual versus single), termination style (gull wing versus SMD tab), and package footprint. Circuit board redesign and application validation are required.

Q: What is the functional difference between vented gauge and differential pressure measurement?

A: Vented gauge pressure is measured relative to atmospheric pressure through an internal vent. Differential pressure is measured as the difference between two independent pressure inputs. These measurement principles produce different output characteristics for the same physical pressure stimulus.

Q: Are both parts ROHS3 compliant?

A: Yes. Both the MPXV5004GVP and MPXV5004DP are ROHS3 compliant.

Q: What is the impact of the different termination styles on PCB design?

A: SMD tab termination (MPXV5004GVP) and gull wing termination (MPXV5004DP) require different solder pad geometries and reflow profiles. PCB layout must be redesigned to accommodate the new package footprint.

Q: Are the output voltage ranges identical?

A: Yes. Both parts deliver analog voltage output in the range of 1 V to 4.9 V with identical supply voltage requirements of 4.75 V to 5.25 V.

Q: What are the port configuration differences?

A: The MPXV5004GVP has a single male barbed port for vented gauge measurement. The MPXV5004DP has dual male barbed ports on the same side for differential pressure measurement between two independent sources.

Request Quote (Ships tomorrow)