MPXV5004GC7U Equivalent & Substitute Parts

Part Overview

The MPXV5004GC7U is a vented gauge pressure sensor manufactured by NXP USA Inc., designed for board mount applications requiring low-pressure measurement up to 0.57 PSI (3.92 kPa). This sensor outputs analog voltage signals between 1 V and 4.9 V and features temperature compensation for stable operation across 0°C to 85°C. The product is currently obsolete, making identification of compatible substitute parts essential for system maintenance, redesign, and procurement planning.

Substiute Parts

MPXV5004GC7U
NXP USA Inc.In Stock: 2390MPXV5004GC7U Datasheet
MPXV5004GC7U
Current Part
MPVZ5004GW7U
NXP USA Inc.In Stock: 4413MPVZ5004GW7U Datasheet
MPVZ5004GW7U
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number MPXV5004GC7U
Manufacturer NXP USA Inc.
Series MPXV5004
Product Status Obsolete
Pressure Type Vented Gauge
Operating Pressure 0.57 PSI (3.92 kPa)
Output Type Analog Voltage
Output Range 1 V ~ 4.9 V
Supply Voltage 4.75 V ~ 5.25 V
Port Size Male - 0.13" (3.17 mm) Tube
Port Style Barbless
Mounting Type Through Hole
Package / Case 8-DIP (0.550", 13.97 mm), Top Port
Operating Temperature 0°C ~ 85°C
Features Temperature Compensated
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution of the MPXV5004GC7U is determined by the following critical parameters that must remain consistent:

  • Pressure measurement range: 0.57 PSI (3.92 kPa) vented gauge
  • Output signal type: Analog voltage 1 V ~ 4.9 V
  • Supply voltage: 4.75 V ~ 5.25 V
  • Mounting configuration: Through hole, 8-DIP package
  • Operating temperature range: 0°C ~ 85°C
  • Port style: Barbless male tube connection

The MPVZ5004GW7U qualifies as a substitute based on matching all critical electrical and functional parameters. The primary difference is the port size (0.22" versus 0.13" tube diameter), which represents a mechanical variation within the same functional category. Both sensors maintain identical pressure ranges, output characteristics, supply voltage requirements, and temperature compensation features.

Parameter Comparison

Parameter MPXV5004GC7U MPVZ5004GW7U
Manufacturer NXP USA Inc. NXP USA Inc.
Product Status Obsolete Active
Pressure Type Vented Gauge Vented Gauge
Operating Pressure 0.57 PSI (3.92 kPa) 0.57 PSI (3.92 kPa)
Output Type Analog Voltage Analog Voltage
Output Range 1 V ~ 4.9 V 1 V ~ 4.9 V
Supply Voltage 4.75 V ~ 5.25 V 4.75 V ~ 5.25 V
Port Style Barbless Barbless
Port Size Male - 0.13" (3.17 mm) Tube Male - 0.22" (5.59 mm) Tube
Mounting Type Through Hole Through Hole
Package / Case 8-DIP (0.550", 13.97 mm), Top Port 8-DIP Module
Operating Temperature 0°C ~ 85°C 0°C ~ 85°C
Features Temperature Compensated Temperature Compensated
RoHS Status ROHS3 Compliant ROHS3 Compliant

Engineering Selection Recommendations

The MPVZ5004GW7U is the recommended substitute for the obsolete MPXV5004GC7U. Both components are manufactured by NXP USA Inc. and maintain identical electrical specifications, pressure measurement capabilities, and output characteristics. The MPVZ5004GW7U holds active product status, ensuring ongoing availability and supply chain continuity.

Both parts comply with ROHS3 standards and maintain REACH unaffected status, meeting current regulatory requirements. The primary consideration for selection is the port size difference: the MPVZ5004GW7U features a 0.22" (5.59 mm) tube connection compared to the 0.13" (3.17 mm) tube of the original part. This mechanical difference requires verification against system tubing specifications and connection requirements.

Frequently Asked Questions (FAQ)

Q: Can the MPVZ5004GW7U directly replace the MPXV5004GC7U in existing designs?

A: Electrical and functional compatibility is complete. The primary consideration is the port size difference. The MPVZ5004GW7U uses a 0.22" tube connection versus the 0.13" tube of the original part. Verify that system tubing and connection fittings accommodate the larger port diameter.

Q: What is the significance of the product status difference?

A: The MPXV5004GC7U is obsolete, indicating discontinued manufacturing and limited availability. The MPVZ5004GW7U is active, ensuring reliable procurement and ongoing manufacturer support.

Q: Are the output voltage ranges identical?

A: Yes. Both sensors output 1 V ~ 4.9 V across the 0.57 PSI measurement range and operate with identical 4.75 V ~ 5.25 V supply voltage requirements.

Q: Do both sensors require the same operating temperature range?

A: Yes. Both components operate across 0°C ~ 85°C with temperature compensation features.

Q: What packaging differences exist between these parts?

A: Both use 8-DIP through-hole mounting. The MPXV5004GC7U specifies 8-DIP (0.550", 13.97 mm) with top port, while the MPVZ5004GW7U is specified as 8-DIP Module. Pin configuration and electrical interface remain compatible.

Q: Are there accuracy differences between the two sensors?

A: The MPVZ5004GW7U specifies ±6.25% accuracy. The MPXV5004GC7U accuracy specification was not provided in the available data.

Request Quote (Ships tomorrow)