MPX5010GSX Equivalent & Substitute Parts

Part Overview

The MPX5010GSX is a vented gauge pressure sensor manufactured by NXP USA Inc., designed for board mount applications requiring low-pressure measurement up to 1.45 PSI (10 kPa). This sensor outputs analog voltage signals between 0.2 V and 4.7 V and features temperature compensation for stable operation across -40°C to 125°C. The MPX5010GSX is classified as obsolete, making identification of equivalent and substitute parts essential for ongoing system support and new design implementations.

Substiute Parts

MPX5010GSX
NXP USA Inc.In Stock: 882MPX5010GSX Datasheet
MPX5010GSX
Current Part
MPX5010DP
NXP USA Inc.In Stock: 28437MPX5010DP Datasheet
MPX5010DP
MFR Recommended
MPX5010GP
NXP SemiconductorsIn Stock: 1396MPX5010GP Datasheet
MPX5010GP
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number MPX5010GSX
Manufacturer NXP USA Inc.
Series MPX5010
Product Status Obsolete
Pressure Type Vented Gauge
Operating Pressure 1.45 PSI (10 kPa)
Output Type Analog Voltage
Output Range 0.2 V ~ 4.7 V
Accuracy ±5%
Supply Voltage 4.75 V ~ 5.25 V
Port Size Male - 0.19" (4.93 mm) Tube
Port Style Barbed
Package / Case 6-SIP Module
Mounting Type Through Hole
Operating Temperature -40°C ~ 125°C
Maximum Pressure 5.8 PSI (40 kPa)
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution for the MPX5010GSX is determined by the following critical parameters that must remain consistent:

Mandatory Matching Parameters:

  • Series: MPX5010
  • Package / Case: 6-SIP Module
  • Mounting Type: Through Hole
  • Port Size: Male - 0.19" (4.93 mm) Tube
  • Port Style: Barbed
  • Supply Voltage: 4.75 V ~ 5.25 V
  • Output Range: 0.2 V ~ 4.7 V
  • Accuracy: ±5%
  • Operating Temperature: -40°C ~ 125°C
  • Maximum Pressure: 5.8 PSI (40 kPa)

Variable Parameter (Pressure Type): The MPX5010GSX operates as a vented gauge sensor. Substitute parts may differ in pressure type classification (vented gauge vs. differential) while maintaining all other electrical and mechanical specifications. This distinction affects how the sensor responds to pressure differential but does not impact physical compatibility or electrical interface.

Parameter Comparison

Parameter MPX5010GSX (Main) MPX5010GP (Substitute) MPX5010DP (Substitute)
Manufacturer NXP USA Inc. NXP Semiconductors NXP USA Inc.
Product Status Obsolete Active Active
Pressure Type Vented Gauge Vented Gauge Differential
Operating Pressure 1.45 PSI (10 kPa) 1.45 PSI (10 kPa) 1.45 PSI (10 kPa)
Output Type Analog Voltage Analog Voltage Analog Voltage
Output Range 0.2 V ~ 4.7 V 0.2 V ~ 4.7 V 0.2 V ~ 4.7 V
Accuracy ±5% ±5% ±5%
Supply Voltage 4.75 V ~ 5.25 V 4.75 V ~ 5.25 V 4.75 V ~ 5.25 V
Port Size Male - 0.19" (4.93 mm) Tube Male - 0.19" (4.93 mm) Tube Male - 0.19" (4.93 mm) Tube, Dual
Port Style Barbed Barbed Barbed
Package / Case 6-SIP Module 6-SIP Module 6-SIP Module
Mounting Type Through Hole Through Hole Through Hole
Operating Temperature -40°C ~ 125°C -40°C ~ 125°C -40°C ~ 125°C
Maximum Pressure 5.8 PSI (40 kPa) 5.8 PSI (40 kPa) 5.8 PSI (40 kPa)
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant

Engineering Selection Recommendations

MPX5010GP is the direct equivalent for the obsolete MPX5010GSX. Both sensors maintain identical pressure type classification (vented gauge), electrical specifications, and mechanical form factor. The MPX5010GP is currently in active production status with confirmed inventory availability. This part is recommended as the primary replacement for direct substitution in existing designs.

MPX5010DP is an alternative substitute with active product status and high inventory availability. This sensor differs in pressure type (differential vs. vented gauge) and features dual port configuration. Selection of the MPX5010DP requires system-level evaluation to confirm that differential pressure measurement is functionally compatible with the application. Both parts maintain identical electrical output characteristics, supply voltage requirements, accuracy specifications, and operating temperature range.

All substitute parts maintain ROHS3 compliance and REACH unaffected status, consistent with the original MPX5010GSX specifications.

Frequently Asked Questions (FAQ)

Q: Can the MPX5010GP directly replace the MPX5010GSX without circuit modifications?

A: Yes. The MPX5010GP maintains identical electrical specifications (output range 0.2 V ~ 4.7 V, supply voltage 4.75 V ~ 5.25 V, accuracy ±5%), mechanical form factor (6-SIP Module, through hole mounting), and pressure type (vented gauge). No circuit modifications are required.

Q: What is the functional difference between the MPX5010GSX and MPX5010DP?

A: The primary difference is pressure type. The MPX5010GSX measures vented gauge pressure (pressure relative to atmospheric reference). The MPX5010DP measures differential pressure (pressure difference between two independent ports). Both maintain identical electrical output characteristics and operating specifications. Application compatibility depends on whether the system requires gauge or differential pressure measurement.

Q: Are there packaging differences between substitute parts?

A: The MPX5010GSX and MPX5010GP are supplied in tray packaging. The MPX5010DP is also supplied in tray packaging. All three parts use identical 6-SIP Module package / case configuration with through hole mounting. Port configuration differs: MPX5010GSX and MPX5010GP feature single male 0.19" (4.93 mm) barbed tube ports, while MPX5010DP features dual male 0.19" (4.93 mm) barbed tube ports.

Q: Are all substitute parts RoHS and REACH compliant?

A: Yes. The MPX5010GSX, MPX5010GP, and MPX5010DP are all ROHS3 compliant and REACH unaffected, meeting current environmental and regulatory requirements.

Q: What is the inventory status of substitute parts?

A: The MPX5010GP has 1,295 pieces in stock. The MPX5010DP has 28,408 pieces in stock. Both are classified as active products with confirmed availability.

Request Quote (Ships tomorrow)