MPL-1036S Equivalent & Substitute Parts Reference

Part Overview

The Sanken Electric MPL-1036S is a general purpose, fast recovery diode rated at 600 V and 3 A, designed for surface mount applications in the TO-263 (D2PAK) package. This device is categorized under Diodes, Rectifiers and features standard rectifier technology with a reverse recovery time of 50 ns, suitable for high-speed switching applications. Its product status is listed as Obsolete, making it critical to identify suitable alternative models to maintain production continuity or service existing equipment. Compatible replacement diodes must strictly match electrical and mechanical characteristics as outlined in the available parameters.

Substiute Parts

MPL-1036S
Sanken Electric USA Inc.In Stock: 1144MPL-1036S Datasheet
MPL-1036S
Current Part
LXA06B600
Power IntegrationsIn Stock: 5858LXA06B600 Datasheet
LXA06B600
Similar
VS-HFA08TA60CS-M3
Vishay General Semiconductor - Diodes DivisionIn Stock: 9040VS-HFA08TA60CS-M3 Datasheet
VS-HFA08TA60CS-M3
Similar

Key Parameters

ParameterValue
CategoryDiodes, Rectifiers
Voltage - DC Reverse (Vr) (Max)600 V
Current - Average Rectified (Io)3A
Voltage - Forward (Vf) (Max) @ If1.75 V @ 3 A
SpeedFast Recovery =< 500ns, > 200mA (Io)
Reverse Recovery Time (trr)50 ns
Current - Reverse Leakage @ Vr50 µA @ 600 V
Mounting TypeSurface Mount
Package / CaseTO-263-3, D2PAK (2 Leads + Tab), TO-263AB
Operating Temperature - Junction-40°C ~ 150°C
RoHS StatusRoHS Compliant

Substitute Part Grouping Explanation

Substitute parts for the MPL-1036S are selected strictly according to the provided electrical and mechanical parameters: reverse voltage rating, average rectified current, forward voltage at nominal current, reverse recovery speed, reverse leakage current, surface mount package compatibility (specifically TO-263 variants), and RoHS status. Substitute parts must match or exceed these criteria without deviating from the defined package and compliance requirements.

Parameter Comparison

Part Number Manufacturer Vr (Max) Io Vf (Max) @ If Speed (Fast Recovery) Reverse Recovery Time (trr) Reverse Leakage @ Vr Mounting Type Package / Case Operating Temperature - Junction RoHS Status
MPL-1036S Sanken Electric USA Inc. 600 V 3A 1.75 V @ 3 A ≤ 500ns, >200mA 50 ns 50 µA @ 600 V Surface Mount TO-263-3, D2PAK (2 Leads + Tab), TO-263AB -40°C ~ 150°C RoHS Compliant
LXA06B600 Power Integrations 600 V 6A 2.94 V @ 6 A ≤ 500ns, >200mA 23 ns 250 µA @ 600 V Surface Mount TO-263-3, D2PAK (2 Leads + Tab), TO-263AB 150°C (Max) RoHS Compliant
VS-HFA08TA60CS-M3 Vishay General Semiconductor - Diodes Division 600 V 4A (DC) per Diode 2.2 V @ 8 A ≤ 500ns, >200mA 42 ns 3 µA @ 600 V Surface Mount TO-263-3, D2PAK (2 Leads + Tab), TO-263AB -55°C ~ 150°C ROHS3 Compliant

Engineering Selection Recommendations

The MPL-1036S is an obsolete product. Both LXA06B600 and VS-HFA08TA60CS-M3 are listed as active status and comply with RoHS requirements. All substitute parts use the same surface mount TO-263-3, D2PAK (2 Leads + Tab), or TO-263AB packages. Substitute parts are compliant with specified environmental standards, ensuring continued compliance in regulated applications.

Frequently Asked Questions (FAQ)

Q1: Which parameters determine if a diode, rectifier can substitute MPL-1036S?
A1: Substitute parts must match or exceed the reverse voltage rating (600 V), average rectified current, similar or faster recovery speed, equal or lower reverse recovery time, comparable reverse leakage at maximum rated voltage, surface mount compatibility in TO-263 or D2PAK packages, and RoHS status.

Q2: Why is the package type important for substitution?
A2: All parts must use the TO-263-3, D2PAK (2 Leads + Tab), or TO-263AB package to ensure mechanical fit and thermal performance in the application.

Q3: Are all substitute diodes RoHS compliant?
A3: Yes, all substitute part numbers listed (LXA06B600 and VS-HFA08TA60CS-M3) are RoHS or ROHS3 compliant as per provided parameters.

Q4: Can other diodes outside the provided list be considered as substitutes?
A4: Only diodes explicitly listed with matching or exceeding the provided key parameters are included as substitutes in this reference page.

Q5: Are there differences in maximum operating temperature among the options?
A5: The MPL-1036S and VS-HFA08TA60CS-M3 have a maximum junction temperature of at least 150°C; LXA06B600 specifies a maximum of 150°C.

Q6: What is the relevance of product status (active/obsolete)?
A6: Obsolete parts require substitution to avoid supply chain disruptions; only active status variants should be selected for new designs or ongoing production.