MLH300PSB02A Equivalent & Substitute Parts

Part Overview

The MLH300PSB02A is a sealed gauge pressure sensor manufactured by Honeywell Sensing and Productivity Solutions. This component is classified as obsolete and has been superseded in active production. The sensor delivers amplified analog voltage output (0.5 V to 4.5 V) for pressure measurements up to 300 PSI in industrial automation applications. Due to its obsolete status, identifying functionally equivalent active production alternatives is essential for system maintenance, redesign, and procurement continuity.

Substiute Parts

MLH300PSB02A
Honeywell Sensing and Productivity SolutionsIn Stock: 1077MLH300PSB02A Datasheet
MLH300PSB02A
Current Part
MLH300PSB01A
Honeywell Sensing and Productivity SolutionsIn Stock: 940MLH300PSB01A Datasheet
MLH300PSB01A
Similar

Key Parameters

Parameter Value
Manufacturer Honeywell Sensing and Productivity Solutions
Series MLH
Base Product Number MLH300
Pressure Type Sealed Gauge
Operating Pressure 300 PSI (2068.43 kPa)
Output Type Analog Voltage
Output Range 0.5 V to 4.5 V
Accuracy ±0.25%
Supply Voltage 5 V to 6 V
Features Amplified Output, Temperature Compensated
Termination Style Packard Metripak 150
Maximum Pressure 900 PSI (6205.28 kPa)
Operating Temperature Range -40°C to 125°C
Package / Case Cylinder, Metal
RoHS Status RoHS Compliant
MSL Rating 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the MLH300PSB02A is determined by strict equivalence across the following critical parameters:

Mandatory Matching Parameters:

  • Sealed gauge pressure type
  • 300 PSI operating pressure rating
  • 0.5 V to 4.5 V analog voltage output
  • ±0.25% accuracy specification
  • 5 V to 6 V supply voltage requirement
  • Amplified output with temperature compensation
  • Packard Metripak 150 termination
  • 900 PSI maximum pressure rating
  • -40°C to 125°C operating temperature range
  • Cylinder metal package configuration
  • RoHS compliance

Variable Parameters (Non-Critical for Substitution):

  • Port size and style (threaded connections may differ: M12 x 1.5 versus 1/4" NPT)
  • Product status (obsolete versus active production)
  • Packaging format (bulk versus other configurations)

The MLH300PSB01A qualifies as a direct substitute based on complete alignment of all mandatory parameters. The primary difference is the port connection type: the MLH300PSB02A uses a male M12 x 1.5 threaded port, while the MLH300PSB01A uses a male 1/4" NPT threaded port. Both are threaded connection styles suitable for industrial pressure measurement installations.

Parameter Comparison

Parameter MLH300PSB02A (Main Part) MLH300PSB01A (Substitute) Match Status
Manufacturer Honeywell Sensing and Productivity Solutions Honeywell Sensing and Productivity Solutions Identical
Series MLH MLH Identical
Base Product Number MLH300 MLH300 Identical
Pressure Type Sealed Gauge Sealed Gauge Identical
Operating Pressure 300 PSI (2068.43 kPa) 300 PSI (2068.43 kPa) Identical
Output Type Analog Voltage Analog Voltage Identical
Output Range 0.5 V to 4.5 V 0.5 V to 4.5 V Identical
Accuracy ±0.25% ±0.25% Identical
Supply Voltage 5 V to 6 V 5 V to 6 V Identical
Features Amplified Output, Temperature Compensated Amplified Output, Temperature Compensated Identical
Termination Style Packard Metripak 150 Packard Metripak 150 Identical
Maximum Pressure 900 PSI (6205.28 kPa) 900 PSI (6205.28 kPa) Identical
Operating Temperature Range -40°C to 125°C -40°C to 125°C Identical
Package / Case Cylinder, Metal Cylinder, Metal Identical
RoHS Status RoHS Compliant RoHS Compliant Identical
MSL Rating 1 (Unlimited) 1 (Unlimited) Identical
Port Size Male - M12 x 1.5 Male - 1/4" (6.35 mm) NPT Different
Product Status Obsolete Active Different

Engineering Selection Recommendations

The MLH300PSB01A is the active production equivalent of the obsolete MLH300PSB02A. Both components share identical electrical specifications, pressure ratings, output characteristics, and environmental operating ranges. Selection between these parts is determined by port connection requirements:

MLH300PSB02A Selection Criteria:

  • Existing installations with M12 x 1.5 threaded port connections
  • Legacy system maintenance where port compatibility is fixed
  • Note: This part is obsolete and subject to limited availability

MLH300PSB01A Selection Criteria:

  • New designs and system implementations
  • Installations requiring 1/4" NPT threaded port connections
  • Preferred choice for ongoing procurement due to active production status
  • Ensures long-term supply chain continuity and support

Both parts carry RoHS compliance certification and identical MSL ratings, confirming environmental and regulatory equivalence. The choice between M12 x 1.5 and 1/4" NPT port styles is a mechanical interface decision that does not affect sensor performance, accuracy, or electrical output characteristics.

Frequently Asked Questions (FAQ)

Q: Can MLH300PSB01A directly replace MLH300PSB02A in existing installations?

A: Electrical and functional replacement is complete. However, the port connection type differs: MLH300PSB02A uses M12 x 1.5 threading, while MLH300PSB01A uses 1/4" NPT threading. Physical installation compatibility depends on the existing port adapter or manifold configuration. Mechanical interface verification is required before installation.

Q: Why is MLH300PSB02A listed as obsolete?

A: The MLH300PSB02A has been superseded by the MLH300PSB01A in Honeywell's active product line. The obsolete designation indicates that the manufacturer no longer produces this specific variant, though existing inventory may remain available through authorized distributors.

Q: Are the electrical output characteristics identical between these two parts?

A: Yes. Both sensors deliver 0.5 V to 4.5 V analog voltage output with ±0.25% accuracy, operate on 5 V to 6 V supply voltage, and include amplified output with temperature compensation. The output signal conditioning and electrical interface are functionally equivalent.

Q: What is the significance of the Packard Metripak 150 termination?

A: Packard Metripak 150 is the electrical connector standard for both parts. This standardized termination ensures compatibility with existing wiring harnesses and connector assemblies designed for MLH series pressure sensors.

Q: Can these sensors be used interchangeably in sealed gauge pressure measurement applications?

A: Yes, for sealed gauge pressure measurement up to 300 PSI with -40°C to 125°C operating conditions. The sealed gauge type means both sensors measure pressure relative to a sealed reference, not atmospheric pressure. Functional interchangeability is confirmed across all electrical and environmental parameters.

Q: What is the difference between M12 x 1.5 and 1/4" NPT port connections?

A: Both are threaded mechanical connections for pressure port installation. M12 x 1.5 is a metric thread specification (12 mm diameter, 1.5 mm pitch), while 1/4" NPT is a National Pipe Thread standard (1/4 inch diameter). The choice depends on the pressure manifold or adapter configuration in the target installation.

Q: Are there any compliance or certification differences between these parts?

A: No. Both MLH300PSB02A and MLH300PSB01A carry identical RoHS compliance certification, MSL rating of 1 (Unlimited), and equivalent regulatory classifications (ECCN: EAR99, HTSUS: 9026.20.4000).