MLH016BGL01B Equivalent & Substitute Parts Reference

Part Overview

The MLH016BGL01B is a vented gauge pressure sensor manufactured by Honeywell Sensing and Productivity Solutions. This component is classified as an all-metal press sense transducer with amplified analog current output, designed for industrial automation applications. The part is currently listed with obsolete product status, which necessitates identification of equivalent substitute components to maintain system continuity and procurement flexibility. The sensor operates within a 4 mA to 20 mA output range with ±0.25% accuracy and supports supply voltages from 9.5V to 30V.

Substiute Parts

MLH016BGL01B
Honeywell Sensing and Productivity SolutionsIn Stock: 1155MLH016BGL01B Datasheet
MLH016BGL01B
Current Part
MLH016BGB01B
Honeywell Sensing and Productivity SolutionsIn Stock: 1114MLH016BGB01B Datasheet
MLH016BGB01B
Similar

Key Parameters

Parameter Value
Manufacturer Part Number MLH016BGL01B
Manufacturer Honeywell Sensing and Productivity Solutions
Series MLH
Pressure Type Vented Gauge
Operating Pressure 232.06 PSI (1600 kPa)
Maximum Pressure 696.18 PSI (4800 kPa)
Output Type Analog Current
Output Range 4 mA ~ 20 mA
Accuracy ±0.25%
Voltage Supply 9.5V ~ 30V
Port Size Male - 1/4" (6.35 mm) NPT
Port Style Threaded
Operating Temperature -40°C ~ 125°C
Package / Case Cylinder, Metal
Features Amplified Output, Temperature Compensated
RoHS Status RoHS Compliant
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution eligibility for the MLH016BGL01B is determined by strict alignment across the following critical parameters:

Pressure Specifications: Operating pressure of 232.06 PSI (1600 kPa) and maximum pressure of 696.18 PSI (4800 kPa) must be matched exactly.

Output Characteristics: Analog current output type with 4 mA to 20 mA range and ±0.25% accuracy are non-negotiable substitution criteria.

Electrical Requirements: Supply voltage range of 9.5V to 30V must be supported.

Mechanical Interface: Male 1/4" (6.35 mm) NPT threaded port size and cylinder metal package configuration must be identical.

Environmental Performance: Operating temperature range of -40°C to 125°C and temperature compensation feature must be maintained.

Regulatory Compliance: RoHS compliance status must be equivalent or superior.

Sensor Type: Vented gauge pressure type must be preserved.

The MLH016BGB01B qualifies as a substitute part based on complete alignment with all specified parameters listed above.

Parameter Comparison

Parameter MLH016BGL01B (Main Part) MLH016BGB01B (Substitute) Match Status
Manufacturer Honeywell Sensing and Productivity Solutions Honeywell Sensing and Productivity Solutions Identical
Series MLH MLH Identical
Pressure Type Vented Gauge Vented Gauge Identical
Operating Pressure 232.06 PSI (1600 kPa) 232.06 PSI (1600 kPa) Identical
Maximum Pressure 696.18 PSI (4800 kPa) 696.18 PSI (4800 kPa) Identical
Output Type Analog Current Analog Current Identical
Output Range 4 mA ~ 20 mA 4 mA ~ 20 mA Identical
Accuracy ±0.25% ±0.25% Identical
Voltage Supply 9.5V ~ 30V 9.5V ~ 30V Identical
Port Size Male - 1/4" (6.35 mm) NPT Male - 1/4" (6.35 mm) NPT Identical
Port Style Threaded Threaded Identical
Operating Temperature -40°C ~ 125°C -40°C ~ 125°C Identical
Package / Case Cylinder, Metal Cylinder, Metal Identical
Features Amplified Output, Temperature Compensated Amplified Output, Temperature Compensated Identical
RoHS Status RoHS Compliant RoHS Compliant Identical
Product Status Obsolete Active Substitute is Active

Engineering Selection Recommendations

The MLH016BGB01B is a direct functional equivalent to the MLH016BGL01B across all specified electrical, mechanical, and environmental parameters. The primary distinction is product status: the MLH016BGL01B is obsolete while the MLH016BGB01B maintains active status with Honeywell Sensing and Productivity Solutions.

Both components are RoHS compliant and share identical pressure specifications, output characteristics, supply voltage requirements, and mechanical interfaces. The substitute part is suitable for new designs and replacement applications where the MLH016BGL01B is no longer available through standard procurement channels.

The MLH016BGB01B includes a Packard Metripak 150 termination style specification, which represents a defined connector interface. This termination specification should be verified against existing system wiring and connector compatibility requirements during integration planning.

Frequently Asked Questions (FAQ)

Q: Can the MLH016BGB01B directly replace the MLH016BGL01B in existing installations?

A: The MLH016BGB01B matches all critical electrical and mechanical parameters of the MLH016BGL01B, including pressure range, output type, supply voltage, port size, and operating temperature. The primary consideration is the Packard Metripak 150 termination style on the substitute part, which must be compatible with existing connector interfaces in the application.

Q: What is the significance of the product status difference between these parts?

A: The MLH016BGL01B is classified as obsolete, indicating it is no longer manufactured or supported by Honeywell. The MLH016BGB01B maintains active status, ensuring continued availability, technical support, and compliance with current manufacturing standards.

Q: Are there any differences in accuracy or pressure specifications between these sensors?

A: No. Both parts specify ±0.25% accuracy, 232.06 PSI (1600 kPa) operating pressure, and 696.18 PSI (4800 kPa) maximum pressure. These critical parameters are identical.

Q: What is the Packard Metripak 150 termination style?

A: Packard Metripak 150 is a standardized electrical connector interface used in automotive and industrial applications. Compatibility with existing wiring harnesses and connectors must be confirmed before implementation.

Q: Do both parts support the same supply voltage range?

A: Yes. Both the MLH016BGL01B and MLH016BGB01B operate with supply voltages from 9.5V to 30V and produce identical 4 mA to 20 mA analog current output.

Q: Are both parts RoHS compliant?

A: Yes. Both components are RoHS compliant, meeting environmental and regulatory requirements for restricted substances.