MLF2012A1R8MT Equivalent & Substitute Parts

Part Overview

The MLF2012A1R8MT is a 1.8 µH shielded multilayer inductor manufactured by TDK Corporation in 0805 (2012 Metric) surface mount package. This component is rated for 80 mA maximum current with 450 mOhm maximum DC resistance and operates across -55°C to 125°C. The part is currently marked as Not For New Designs, making identification of suitable alternatives essential for ongoing production and new design implementations.

Substiute Parts

MLF2012A1R8MT
TDK CorporationIn Stock: 1189MLF2012A1R8MT Datasheet
MLF2012A1R8MT
Current Part
MLF2012A1R8KTD25
TDK CorporationIn Stock: 6259MLF2012A1R8KTD25 Datasheet
MLF2012A1R8KTD25
Direct

Key Parameters

Parameter Value
Inductance 1.8 µH
Current Rating 80 mA
DC Resistance (Max) 450 mOhm
Package / Case 0805 (2012 Metric)
Shielding Shielded
Material - Core Ferrite
Operating Temperature Range -55°C ~ 125°C
Mounting Type Surface Mount

Substitute Part Grouping Explanation

Substitution of the MLF2012A1R8MT is determined by strict equivalence across the following critical parameters:

  • Inductance value: 1.8 µH (exact match required)
  • Current rating: 80 mA minimum
  • DC resistance: 450 mOhm maximum
  • Package: 0805 (2012 Metric) surface mount
  • Shielding type: Shielded construction
  • Core material: Ferrite
  • Operating temperature range: -55°C to 125°C minimum

The MLF2012A1R8KTD25 meets all substitution criteria as a direct equivalent from the same manufacturer series.

Parameter Comparison

Parameter MLF2012A1R8MT MLF2012A1R8KTD25
Manufacturer TDK Corporation TDK Corporation
Series MLF MLF
Inductance 1.8 µH 1.8 µH
Tolerance ±20% ±10%
Current Rating (Amps) 80 mA 80 mA
DC Resistance (Max) 450 mOhm 450 mOhm
Q @ 10MHz 45 45
Frequency - Self Resonant 90 MHz 90 MHz
Operating Temperature -55°C ~ 125°C -55°C ~ 125°C
Package / Case 0805 (2012 Metric) 0805 (2012 Metric)
Size / Dimension 0.079" L x 0.049" W (2.00mm x 1.25mm) 0.079" L x 0.049" W (2.00mm x 1.25mm)
Height - Seated (Max) 0.041" (1.05mm) 0.041" (1.05mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
Product Status Not For New Designs Active

Engineering Selection Recommendations

The MLF2012A1R8KTD25 is the direct substitute for MLF2012A1R8MT applications. Both components share identical electrical specifications, physical dimensions, and environmental ratings. The primary distinction is product lifecycle status: MLF2012A1R8MT is marked Not For New Designs, while MLF2012A1R8KTD25 maintains Active status.

The MLF2012A1R8KTD25 offers improved inductance tolerance (±10% versus ±20%), providing tighter performance control in circuit applications. Both parts carry ROHS3 compliance and AEC-Q200 automotive qualification on the substitute part, supporting applications requiring automotive-grade reliability.

Frequently Asked Questions (FAQ)

Q: Can MLF2012A1R8KTD25 directly replace MLF2012A1R8MT in existing designs?

A: Yes. Both parts are electrically and mechanically equivalent across all critical parameters: 1.8 µH inductance, 80 mA current rating, 450 mOhm maximum DC resistance, and 0805 (2012 Metric) package. PCB layout and assembly processes require no modification.

Q: What is the difference in inductance tolerance between these parts?

A: MLF2012A1R8MT specifies ±20% tolerance, while MLF2012A1R8KTD25 specifies ±10% tolerance. The tighter tolerance of the substitute part provides improved circuit performance consistency.

Q: Are both parts suitable for high-temperature applications?

A: Both parts operate across -55°C to 125°C, meeting standard industrial and automotive temperature requirements.

Q: Why is MLF2012A1R8MT marked Not For New Designs?

A: This designation indicates the part is in end-of-life phase. MLF2012A1R8KTD25 is the recommended active alternative for new design implementations.

Q: Do these parts require different handling or storage procedures?

A: Both parts carry Moisture Sensitivity Level 1 (Unlimited), indicating no special moisture control requirements during storage or handling.

Request Quote (Ships tomorrow)