Omron MKS3P-2 AC220 General Purpose Relay – Equivalent & Substitute Parts

Part Overview

The Omron MKS3P-2 AC220 is a general purpose relay with 3PDT (3 Form C) contact configuration rated for 10A at 220VAC coil voltage. This socketable relay features an 11-pin octal termination and mechanical indicator, designed for industrial control applications requiring reliable switching performance across a wide operating temperature range. The part is currently active in production with robust inventory availability. Equivalent and substitute parts are identified to support procurement flexibility, design revisions, and supply chain continuity.

Substiute Parts

MKS3P-2 AC220
Omron Automation and SafetyIn Stock: 794MKS3P-2 AC220 Datasheet
MKS3P-2 AC220
Current Part
MKS3P AC220
Omron Automation and SafetyIn Stock: 753MKS3P AC220 Datasheet
MKS3P AC220
Parametric Equivalent
MKS3P-5 AC220
Omron Automation and SafetyIn Stock: 793MKS3P-5 AC220 Datasheet
MKS3P-5 AC220
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number MKS3P-2 AC220
Manufacturer Omron Automation and Safety
Series MKS
Relay Type General Purpose
Contact Form 3PDT (3 Form C)
Contact Rating (Current) 10 A
Coil Voltage 220VAC
Switching Voltage 250VAC, 30VDC – Max
Coil Current 10.5 mA
Coil Type Non Latching
Mounting Type Socketable
Termination Style Plug In, 11 Pin (Octal)
Operating Temperature –40°C to 60°C
Contact Material Silver Tin Indium (AgSnIn)
Coil Resistance 4.65 kOhms
Must Operate Voltage 176 VAC
Must Release Voltage 66 VAC
Operate Time 20 ms
Release Time 20 ms
Features Mechanical Indicator
RoHS Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Product Status Active

Substitute Part Grouping Explanation

Substitute parts for the MKS3P-2 AC220 are identified based on strict parametric equivalence across all critical electrical and mechanical specifications. The substitution logic is based on the following key parameters that must remain identical:

  • Contact Form: 3PDT (3 Form C)
  • Contact Rating (Current): 10 A
  • Coil Voltage: 220VAC
  • Switching Voltage: 250VAC, 30VDC – Max
  • Coil Current: 10.5 mA
  • Coil Type: Non Latching
  • Mounting Type: Socketable
  • Termination Style: Plug In, 11 Pin (Octal)
  • Operating Temperature: –40°C to 60°C
  • Contact Material: Silver Tin Indium (AgSnIn)
  • Coil Resistance: 4.65 kOhms
  • Must Operate Voltage: 176 VAC
  • Must Release Voltage: 66 VAC
  • Operate Time: 20 ms
  • Release Time: 20 ms

The identified substitute parts—MKS3P AC220 and MKS3P-5 AC220—maintain complete parametric alignment with the main part across all electrical performance characteristics, mechanical configuration, and environmental specifications. These parts are interchangeable within the same circuit design without modification.

Parameter Comparison

Parameter MKS3P-2 AC220 MKS3P AC220 MKS3P-5 AC220
Manufacturer Omron Automation and Safety Omron Automation and Safety Omron Automation and Safety
Series MKS MKS MKS
Contact Form 3PDT (3 Form C) 3PDT (3 Form C) 3PDT (3 Form C)
Contact Rating (Current) 10 A 10 A 10 A
Coil Voltage 220VAC 220VAC 220VAC
Switching Voltage 250VAC, 30VDC – Max 250VAC, 30VDC – Max 250VAC, 30VDC – Max
Coil Current 10.5 mA 10.5 mA 10.5 mA
Coil Type Non Latching Non Latching Non Latching
Mounting Type Socketable Socketable Socketable
Termination Style Plug In, 11 Pin (Octal) Plug In, 11 Pin (Octal) Plug In, 11 Pin (Octal)
Operating Temperature –40°C to 60°C –40°C to 60°C –40°C to 60°C
Contact Material Silver Tin Indium (AgSnIn) Silver Tin Indium (AgSnIn) Silver Tin Indium (AgSnIn)
Coil Resistance 4.65 kOhms 4.65 kOhms 4.65 kOhms
Must Operate Voltage 176 VAC 176 VAC 176 VAC
Must Release Voltage 66 VAC 66 VAC 66 VAC
Operate Time 20 ms 20 ms 20 ms
Release Time 20 ms 20 ms 20 ms
Features Mechanical Indicator Mechanical Indicator Mechanical Indicator
RoHS Status RoHS Compliant ROHS3 Compliant RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)
Product Status Active Active Active

Engineering Selection Recommendations

All three parts—MKS3P-2 AC220, MKS3P AC220, and MKS3P-5 AC220—are active products from Omron Automation and Safety with full RoHS compliance. The MKS3P AC220 carries ROHS3 certification, while MKS3P-2 AC220 and MKS3P-5 AC220 maintain standard RoHS compliance. All parts meet MSL Level 1 (Unlimited) moisture sensitivity requirements and carry identical electrical and mechanical specifications.

Selection between these parts should be based on procurement availability, inventory status, and compliance requirements specific to the application. The parametric equivalence across all critical specifications ensures direct substitution without circuit redesign or performance degradation.

Frequently Asked Questions (FAQ)

Q: Can MKS3P AC220 and MKS3P-5 AC220 be used interchangeably with MKS3P-2 AC220?

A: Yes. All three parts maintain identical electrical performance, contact configuration, coil specifications, and mechanical mounting. They are direct parametric equivalents suitable for drop-in replacement within the same circuit design.

Q: Are there differences in RoHS compliance between these parts?

A: MKS3P AC220 carries ROHS3 certification, while MKS3P-2 AC220 and MKS3P-5 AC220 maintain RoHS compliance. Both certifications satisfy RoHS requirements; the difference reflects certification revision levels. Application compliance requirements should determine selection if ROHS3 specifically is mandated.

Q: Do these relays require socket bases for installation?

A: Yes. All three parts feature socketable mounting with 11-pin octal termination. Installation requires compatible relay sockets; direct PCB soldering is not applicable.

Q: What is the operating voltage range for these relays?

A: The coil operates at 220VAC nominal. Must Operate Voltage is 176 VAC and Must Release Voltage is 66 VAC, defining the functional voltage window for reliable operation.

Q: Are these parts suitable for high-frequency switching applications?

A: These relays are general purpose devices with 20 ms operate and release times. They are designed for standard industrial control applications, not high-frequency switching. Switching frequency requirements should be evaluated against these timing specifications.

Request Quote (Ships tomorrow)