MK2PD-S-DC12 Equivalent & Substitute Parts

Part Overview

The MK2PD-S-DC12 is a general purpose relay manufactured by Omron Automation and Safety, featuring a DPDT (2 Form C) contact configuration with a 12VDC coil and 10A contact rating. This socketable, 8-pin octal relay is designed for general-purpose switching applications requiring dual-pole, dual-throw functionality.

The MK2PD-S-DC12 is classified as obsolete. Identifying equivalent and substitute parts is necessary to maintain system functionality and ensure continued availability for replacement and new designs.

Substiute Parts

MK2PD-S-DC12
Omron Automation and SafetyIn Stock: 1124MK2PD-S-DC12 Datasheet
MK2PD-S-DC12
Current Part
MKS2PIDC12
Omron Automation and SafetyIn Stock: 886MKS2PIDC12 Datasheet
MKS2PIDC12
Similar

Key Parameters

Parameter Value
Coil Voltage 12VDC
Contact Form DPDT (2 Form C)
Contact Rating (Current) 10 A
Switching Voltage 250VAC, 250VDC - Max
Mounting Type Socketable
Termination Style Plug In, 8 Pin (Octal)
Coil Type Non Latching
Must Operate Voltage 9.6 VDC
Must Release Voltage 1.8 VDC
Operating Temperature Range -10°C ~ 40°C

Substitute Part Grouping Explanation

Substitution of the MK2PD-S-DC12 is based on strict equivalence of the following critical parameters:

  • Coil voltage: 12VDC
  • Contact configuration: DPDT (2 Form C)
  • Contact current rating: 10 A
  • Mounting type: Socketable
  • Termination style: Plug In, 8 Pin (Octal)
  • Coil type: Non Latching

The MKS2PIDC12 meets all these core requirements and is therefore classified as a direct substitute. Both relays share identical coil voltage, contact form, current rating, and physical mounting characteristics, enabling functional replacement in applications designed for the MK2PD-S-DC12.

Parameter Comparison

Parameter MK2PD-S-DC12 MKS2PIDC12
Manufacturer Omron Automation and Safety Omron Automation and Safety
Coil Voltage 12VDC 12VDC
Contact Form DPDT (2 Form C) DPDT (2 Form C)
Contact Rating (Current) 10 A 10 A
Switching Voltage 250VAC, 250VDC - Max 250VAC, 30VDC - Max
Coil Current 126 mA 112 mA
Mounting Type Socketable Socketable
Termination Style Plug In, 8 Pin (Octal) Plug In, 8 Pin (Octal)
Coil Type Non Latching Non Latching
Must Operate Voltage 9.6 VDC 9.6 VDC
Must Release Voltage 1.8 VDC 1.8 VDC
Operate Time 30 ms 30 ms
Release Time 20 ms 20 ms
Operating Temperature Range -10°C ~ 40°C -40°C ~ 60°C
Contact Material Silver (Ag) Silver Tin Indium (AgSnIn)
Coil Resistance 95 Ohms 107 Ohms
Product Status Obsolete Active
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8536.41.0050 8536.41.0050

Engineering Selection Recommendations

The MKS2PIDC12 is the active equivalent for the obsolete MK2PD-S-DC12. Both relays are manufactured by Omron Automation and Safety and share identical electrical and mechanical specifications for coil voltage, contact configuration, current rating, and physical form factor.

The MKS2PIDC12 offers an extended operating temperature range (-40°C ~ 60°C versus -10°C ~ 40°C) and improved coil efficiency (112 mA versus 126 mA). The MKS2PIDC12 is ROHS3 compliant, whereas the MK2PD-S-DC12 compliance status is not specified. Both parts maintain REACH Unaffected and EAR99 ECCN classifications.

For applications requiring DC switching above 30V, the MK2PD-S-DC12 specification of 250VDC maximum switching voltage should be noted against the MKS2PIDC12 specification of 30VDC maximum. Contact material differs between the two relays: the MK2PD-S-DC12 uses silver (Ag), while the MKS2PIDC12 uses silver tin indium (AgSnIn).

Frequently Asked Questions (FAQ)

Q: Can the MKS2PIDC12 directly replace the MK2PD-S-DC12 in existing applications?

A: Yes. Both relays share identical coil voltage (12VDC), contact configuration (DPDT), current rating (10A), mounting type (socketable), and termination style (8-pin octal). The MKS2PIDC12 is the active equivalent for the obsolete MK2PD-S-DC12.

Q: What are the differences in switching voltage specifications?

A: The MK2PD-S-DC12 is rated for 250VAC and 250VDC maximum switching voltage. The MKS2PIDC12 is rated for 250VAC and 30VDC maximum switching voltage. Applications requiring DC switching above 30V should reference the original MK2PD-S-DC12 specification.

Q: How do the coil current specifications differ?

A: The MK2PD-S-DC12 draws 126 mA coil current, while the MKS2PIDC12 draws 112 mA. The MKS2PIDC12 offers improved coil efficiency.

Q: Are there differences in operating temperature ranges?

A: Yes. The MK2PD-S-DC12 operates from -10°C to 40°C. The MKS2PIDC12 operates from -40°C to 60°C, providing a wider temperature operating envelope.

Q: What is the difference in contact material composition?

A: The MK2PD-S-DC12 uses silver (Ag) contact material. The MKS2PIDC12 uses silver tin indium (AgSnIn) contact material. Both materials are suitable for general-purpose switching applications.

Q: What compliance certifications apply to these relays?

A: Both relays maintain REACH Unaffected and EAR99 ECCN classifications. The MKS2PIDC12 is ROHS3 compliant. The MK2PD-S-DC12 compliance status is not specified in the provided data.

Request Quote (Ships tomorrow)