The MJN2C-DC24 is a general purpose relay manufactured by Omron Automation and Safety, featuring a DPDT (2 Form C) contact configuration with a 24VDC coil and 10A contact rating. This socketable relay is designed for applications requiring reliable switching of AC and DC loads. The part is currently active in production with 1900 units in stock. Substitute parts are identified to provide alternative sourcing options for procurement flexibility, inventory management, or supply chain continuity.

Substiute Parts

MJN2C-DC24
Omron Automation and SafetyIn Stock: 1995MJN2C-DC24 Datasheet
MJN2C-DC24
Current Part
KUP-11D15-24
TE Connectivity Potter & Brumfield RelaysIn Stock: 1299KUP-11D15-24 Datasheet
KUP-11D15-24
Direct

Key Parameters

Parameter Value
Coil Voltage 24VDC
Contact Form DPDT (2 Form C)
Contact Rating (Current) 10 A
Mounting Type Socketable
Termination Style Plug In, Quick Connect - 0.187" (4.7mm)
Coil Type Non Latching
Operating Temperature Range -45°C ~ 70°C
Must Operate Voltage 18 VDC

Substitute Part Grouping Explanation

Substitution eligibility for the MJN2C-DC24 is determined by the following critical parameters:

  • Coil Voltage: Must be 24VDC to ensure direct compatibility with existing control circuits
  • Contact Form: Must be DPDT (2 Form C) to maintain identical switching functionality
  • Contact Rating: Must be rated for minimum 10A to handle the same load requirements
  • Mounting Type: Must be socketable to fit existing relay sockets
  • Termination Style: Must use Plug In, Quick Connect - 0.187" (4.7mm) connectors for mechanical compatibility
  • Coil Type: Must be Non Latching for identical operational behavior
  • Operating Temperature Range: Must support -45°C ~ 70°C minimum
  • Must Operate Voltage: Must be 18 VDC or lower to ensure reliable operation at minimum coil voltage

The substitute part KUP-11D15-24 meets all critical substitution criteria and is classified as a direct equivalent.

Parameter Comparison

Parameter MJN2C-DC24 (Omron) KUP-11D15-24 (TE Connectivity) Compatibility
Coil Voltage 24VDC 24VDC Match
Contact Form DPDT (2 Form C) DPDT (2 Form C) Match
Contact Rating (Current) 10 A 10 A Match
Mounting Type Socketable Socketable Match
Termination Style Plug In, Quick Connect - 0.187" (4.7mm) Plug In, Quick Connect - 0.187" (4.7mm) Match
Coil Type Non Latching Non Latching Match
Coil Current 50 mA 51 mA Equivalent
Coil Resistance 470 Ohms 472 Ohms Equivalent
Operate Time 20 ms 15 ms KUP faster
Release Time 10 ms 10 ms Match
Operating Temperature Range -45°C ~ 70°C -45°C ~ 70°C Match
Must Operate Voltage 18 VDC 18 VDC Match
Switching Voltage (Max) 600VAC, 28VDC 240VAC MJN rated higher
Contact Material Silver Alloy Silver Cadmium Oxide (AgCdO) Different
RoHS Status RoHS Compliant RoHS non-compliant Different

Engineering Selection Recommendations

MJN2C-DC24 (Omron) is recommended for applications requiring:

  • RoHS compliance certification
  • Maximum switching voltage capability (600VAC, 28VDC)
  • Silver alloy contact material specifications

KUP-11D15-24 (TE Connectivity) is recommended for applications where:

  • Faster operate time (15 ms vs 20 ms) is beneficial
  • RoHS compliance is not a requirement
  • Maximum switching voltage of 240VAC is sufficient
  • Silver cadmium oxide contact material is acceptable

Both relays are active products with current manufacturing status and meet all critical functional substitution criteria for 24VDC DPDT socketable relay applications.

Frequently Asked Questions (FAQ)

Q: Can KUP-11D15-24 be used as a direct replacement for MJN2C-DC24 in existing circuits?

A: Yes, for applications where the maximum switching voltage of 240VAC is sufficient and RoHS compliance is not required. Both relays share identical coil voltage, contact form, current rating, mounting type, and termination style. The KUP operates 5 ms faster, which may be advantageous in time-sensitive applications.

Q: What is the difference in contact material between these relays?

A: The MJN2C-DC24 uses silver alloy contacts, while the KUP-11D15-24 uses silver cadmium oxide (AgCdO) contacts. Silver cadmium oxide provides enhanced arc resistance and contact life in certain switching applications, while silver alloy offers different electrical characteristics. Selection depends on specific load switching requirements.

Q: Are there RoHS compliance differences between these parts?

A: Yes. The MJN2C-DC24 is RoHS compliant, while the KUP-11D15-24 is RoHS non-compliant and REACH affected. Applications subject to RoHS regulations must use the MJN2C-DC24.

Q: Do both relays fit the same socket?

A: Yes. Both relays are socketable with identical Plug In, Quick Connect - 0.187" (4.7mm) termination, ensuring mechanical compatibility with the same relay socket bases.

Q: What is the significance of the 5 ms difference in operate time?

A: The KUP-11D15-24 operates in 15 ms compared to the MJN2C-DC24 at 20 ms. This 5 ms faster response may be critical in applications requiring rapid switching response, such as protective circuits or high-speed control systems. Both have identical 10 ms release time.

Q: Can these relays be used interchangeably in high-voltage AC applications?

A: No. The MJN2C-DC24 is rated for 600VAC maximum switching voltage, while the KUP-11D15-24 is rated for 240VAC maximum. For applications exceeding 240VAC, only the MJN2C-DC24 is suitable.