Equivalent & Substitute Parts for MJN2C-DC12

Part Overview

The MJN2C-DC12 is a general purpose relay manufactured by Omron Automation and Safety, featuring a DPDT (2 Form C) contact configuration with a 12VDC coil and 10A contact rating. This socketable relay is designed for applications requiring reliable switching of AC and DC loads. The part is currently active in production with 934 units in stock. Substitute parts are identified to provide alternative sourcing options for procurement flexibility, inventory management, or supply chain continuity.

Substiute Parts

MJN2C-DC12
Omron Automation and SafetyIn Stock: 949MJN2C-DC12 Datasheet
MJN2C-DC12
Current Part
KUP-11D15-12
TE Connectivity Potter & Brumfield RelaysIn Stock: 2477KUP-11D15-12 Datasheet
KUP-11D15-12
Direct

Key Parameters

Parameter Value
Coil Voltage 12VDC
Contact Form DPDT (2 Form C)
Contact Rating (Current) 10 A
Mounting Type Socketable
Termination Style Plug In, Quick Connect - 0.187" (4.7mm)
Coil Current 100 mA
Coil Resistance 120 Ohms
Must Operate Voltage 9 VDC
Operating Temperature Range -45°C ~ 70°C
Coil Type Non Latching

Substitute Part Grouping Explanation

Substitution eligibility for the MJN2C-DC12 is determined by strict alignment of the following critical parameters:

  • Coil voltage: 12VDC
  • Contact configuration: DPDT (2 Form C)
  • Contact current rating: 10 A minimum
  • Mounting type: Socketable
  • Termination style: Plug In, Quick Connect - 0.187" (4.7mm)
  • Coil current: 100 mA
  • Coil resistance: 120 Ohms
  • Must operate voltage: 9 VDC minimum
  • Operating temperature range: -45°C ~ 70°C or wider

The KUP-11D15-12 meets all substitution criteria. Variations in switching voltage ratings, contact material composition, operate time, and compliance certifications do not preclude functional substitution when the above parameters are satisfied.

Parameter Comparison

Parameter MJN2C-DC12 (Omron) KUP-11D15-12 (TE Connectivity)
Manufacturer Omron Automation and Safety TE Connectivity Potter & Brumfield Relays
Series MJN KUP
Coil Voltage 12VDC 12VDC
Contact Form DPDT (2 Form C) DPDT (2 Form C)
Contact Rating (Current) 10 A 10 A
Switching Voltage (Max) 600VAC, 28VDC 240VAC
Mounting Type Socketable Socketable
Termination Style Plug In, Quick Connect - 0.187" (4.7mm) Plug In, Quick Connect - 0.187" (4.7mm)
Coil Current 100 mA 100 mA
Coil Resistance 120 Ohms 120 Ohms
Must Operate Voltage 9 VDC 9 VDC
Operate Time 20 ms 15 ms
Release Time 10 ms 10 ms
Operating Temperature -45°C ~ 70°C -45°C ~ 70°C
Contact Material Silver Alloy Silver Cadmium Oxide (AgCdO)
Relay Type General Purpose General Purpose
Product Status Active Active
RoHS Status RoHS Compliant RoHS non-compliant

Engineering Selection Recommendations

Both the MJN2C-DC12 and KUP-11D15-12 are active production relays suitable for general purpose switching applications with identical coil voltage, contact configuration, current rating, and mechanical interface specifications.

The MJN2C-DC12 is RoHS compliant and supports higher maximum switching voltage (600VAC, 28VDC) compared to the KUP-11D15-12 (240VAC maximum). The MJN2C-DC12 also features a longer operate time of 20 ms versus 15 ms for the KUP-11D15-12.

The KUP-11D15-12 is RoHS non-compliant and REACH affected. Selection between these parts should be based on regulatory compliance requirements, maximum switching voltage requirements for the target application, and response time specifications.

Frequently Asked Questions (FAQ)

Q: Can the KUP-11D15-12 directly replace the MJN2C-DC12 in existing designs?

A: Yes, provided the application does not exceed 240VAC maximum switching voltage and the 15 ms operate time of the KUP-11D15-12 is acceptable. Both relays share identical coil voltage, contact configuration, current rating, mounting type, and termination style.

Q: What are the key differences between these two relays?

A: The primary differences are maximum switching voltage rating (MJN2C-DC12: 600VAC/28VDC; KUP-11D15-12: 240VAC), operate time (MJN2C-DC12: 20 ms; KUP-11D15-12: 15 ms), contact material composition, and RoHS compliance status (MJN2C-DC12 compliant; KUP-11D15-12 non-compliant).

Q: Are the physical packages identical?

A: Yes. Both relays use socketable mounting with Plug In, Quick Connect termination at 0.187" (4.7mm) spacing, ensuring mechanical compatibility in relay socket applications.

Q: Which relay should I select for RoHS-compliant applications?

A: The MJN2C-DC12 is RoHS compliant. The KUP-11D15-12 is RoHS non-compliant and REACH affected, making it unsuitable for applications with RoHS compliance requirements.

Q: Do these relays have identical electrical performance?

A: Both relays operate at 12VDC with 100 mA coil current, 120 Ohms coil resistance, and 9 VDC minimum operate voltage. The KUP-11D15-12 has a faster operate time (15 ms vs. 20 ms). The MJN2C-DC12 supports higher switching voltage levels.