Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for Vicor MI-J7T-MZ
Part Overview
The Vicor MI-J7T-MZ is an isolated module DC-DC converter featuring one output at 6.5V and a maximum power output of 25W. It accepts an input voltage range of 100V to 310V, provides isolation up to 3 kV, and includes features such as remote on/off, over-current protection (OCP), over-temperature protection (OTP), and over-voltage protection (OVP). The product is currently designated as obsolete, making it necessary to identify compatible alternative models to ensure continued design support and replacement availability.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Series | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | REACH Status | Product Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MI-J7T-MZ | MI-J00™ (25W) | Isolated Module | 1 | 100V | 310V | 6.5V | 3.8A | 25 W | 3 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP | -55°C ~ 85°C | 90% | Through Hole | 9-DIP Module | 2.40" x 2.28" x 0.50" (61.0mm x 57.9mm x 12.7mm) | RoHS non-compliant | REACH Unaffected | Obsolete |
Substitute Part Grouping Explanation
Substitution is permitted strictly when all key parameters are matched: the electrical characteristics (input/output voltage, output current, power rating, isolation voltage), mechanical format (package/case, mounting type, size/dimension), functional features (protection options, remote on/off), and regulatory status. Compatibility is confirmed when these defined fields are identical.
Parameter Comparison
| Manufacturer Part Number | Series | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | REACH Status | Product Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MI-J7T-MZ | MI-J00™ (25W) | Isolated Module | 1 | 100V | 310V | 6.5V | 3.8A | 25 W | 3 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP | -55°C ~ 85°C | 90% | Through Hole | 9-DIP Module | 2.40" x 2.28" x 0.50" (61.0mm x 57.9mm x 12.7mm) | RoHS non-compliant | REACH Unaffected | Obsolete |
| MI-J7T-MZ-F1 | MI-J00™ (25W) | Isolated Module | 1 | 100V | 310V | 6.5V | 3.8A | 25 W | 3 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP | -55°C ~ 85°C | 90% | Through Hole | 9-DIP Module | 2.40" x 2.28" x 0.50" (61.0mm x 57.9mm x 12.7mm) | RoHS non-compliant | REACH Unaffected | Active |
Engineering Selection Recommendations
For the Vicor MI-J7T-MZ, the substitute model MI-J7T-MZ-F1 is appropriate based solely on matched electrical, mechanical, and functional parameters. Both are RoHS non-compliant and REACH unaffected. MI-J7T-MZ-F1 is active, providing ongoing support for designs requiring direct module replacement. Select in accordance with product status and provided compliance classifications.
Frequently Asked Questions (FAQ)
Q1: Which parameters are essential for substituting Vicor DC-DC converters in the MI-J00™ (25W) series?
A1: Substitution is only valid when input voltage range, output voltage, output current, isolation voltage, efficiency, mounting type, package/case, size/dimension, functional features, and regulatory statuses are identical.
Q2: Are the MI-J7T-MZ and MI-J7T-MZ-F1 compatible for direct replacement?
A2: Yes, both DC-DC converters have identical electrical, mechanical, and compliance parameters; MI-J7T-MZ-F1 is suitable as a direct substitute.
Q3: Does the RoHS non-compliant status affect interchangeability?
A3: RoHS status is matched for both modules, ensuring compliance equivalence.
Q4: Are there mechanical differences between these isolated modules?
A4: Both isolated modules use the same 9-DIP package/case, mounting type, and size/dimension, supporting form-fit compatibility.
Q5: Is it necessary to consider temperature ratings and features when substituting DC-DC module parts?
A5: Yes, operating temperature and functional features (Remote On/Off, OCP, OTP, OVP) must be identical for substitution per strict engineering criteria.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts