Equivalent & Substitute Parts for Vicor MI-J7T-MZ

Part Overview

The Vicor MI-J7T-MZ is an isolated module DC-DC converter featuring one output at 6.5V and a maximum power output of 25W. It accepts an input voltage range of 100V to 310V, provides isolation up to 3 kV, and includes features such as remote on/off, over-current protection (OCP), over-temperature protection (OTP), and over-voltage protection (OVP). The product is currently designated as obsolete, making it necessary to identify compatible alternative models to ensure continued design support and replacement availability.

Substiute Parts

MI-J7T-MZ
Vicor CorporationIn Stock: 803MI-J7T-MZ Datasheet
MI-J7T-MZ
Current Part
MI-J7T-MZ-F1
Vicor CorporationIn Stock: 761MI-J7T-MZ-F1 Datasheet
MI-J7T-MZ-F1
Similar

Key Parameters

Manufacturer Part NumberSeriesTypeNumber of OutputsVoltage - Input (Min)Voltage - Input (Max)Voltage - Output 1Current - Output (Max)Power (Watts)Voltage - IsolationApplicationsFeaturesOperating TemperatureEfficiencyMounting TypePackage / CaseSize / DimensionRoHS StatusREACH StatusProduct Status
MI-J7T-MZ MI-J00™ (25W) Isolated Module 1 100V 310V 6.5V 3.8A 25 W 3 kV ITE (Commercial) Remote On/Off, OCP, OTP, OVP -55°C ~ 85°C 90% Through Hole 9-DIP Module 2.40" x 2.28" x 0.50" (61.0mm x 57.9mm x 12.7mm) RoHS non-compliant REACH Unaffected Obsolete

Substitute Part Grouping Explanation

Substitution is permitted strictly when all key parameters are matched: the electrical characteristics (input/output voltage, output current, power rating, isolation voltage), mechanical format (package/case, mounting type, size/dimension), functional features (protection options, remote on/off), and regulatory status. Compatibility is confirmed when these defined fields are identical.

Parameter Comparison

Manufacturer Part NumberSeriesTypeNumber of OutputsVoltage - Input (Min)Voltage - Input (Max)Voltage - Output 1Current - Output (Max)Power (Watts)Voltage - IsolationApplicationsFeaturesOperating TemperatureEfficiencyMounting TypePackage / CaseSize / DimensionRoHS StatusREACH StatusProduct Status
MI-J7T-MZ MI-J00™ (25W) Isolated Module 1 100V 310V 6.5V 3.8A 25 W 3 kV ITE (Commercial) Remote On/Off, OCP, OTP, OVP -55°C ~ 85°C 90% Through Hole 9-DIP Module 2.40" x 2.28" x 0.50" (61.0mm x 57.9mm x 12.7mm) RoHS non-compliant REACH Unaffected Obsolete
MI-J7T-MZ-F1 MI-J00™ (25W) Isolated Module 1 100V 310V 6.5V 3.8A 25 W 3 kV ITE (Commercial) Remote On/Off, OCP, OTP, OVP -55°C ~ 85°C 90% Through Hole 9-DIP Module 2.40" x 2.28" x 0.50" (61.0mm x 57.9mm x 12.7mm) RoHS non-compliant REACH Unaffected Active

Engineering Selection Recommendations

For the Vicor MI-J7T-MZ, the substitute model MI-J7T-MZ-F1 is appropriate based solely on matched electrical, mechanical, and functional parameters. Both are RoHS non-compliant and REACH unaffected. MI-J7T-MZ-F1 is active, providing ongoing support for designs requiring direct module replacement. Select in accordance with product status and provided compliance classifications.

Frequently Asked Questions (FAQ)

Q1: Which parameters are essential for substituting Vicor DC-DC converters in the MI-J00™ (25W) series?
A1: Substitution is only valid when input voltage range, output voltage, output current, isolation voltage, efficiency, mounting type, package/case, size/dimension, functional features, and regulatory statuses are identical.

Q2: Are the MI-J7T-MZ and MI-J7T-MZ-F1 compatible for direct replacement?
A2: Yes, both DC-DC converters have identical electrical, mechanical, and compliance parameters; MI-J7T-MZ-F1 is suitable as a direct substitute.

Q3: Does the RoHS non-compliant status affect interchangeability?
A3: RoHS status is matched for both modules, ensuring compliance equivalence.

Q4: Are there mechanical differences between these isolated modules?
A4: Both isolated modules use the same 9-DIP package/case, mounting type, and size/dimension, supporting form-fit compatibility.

Q5: Is it necessary to consider temperature ratings and features when substituting DC-DC module parts?
A5: Yes, operating temperature and functional features (Remote On/Off, OCP, OTP, OVP) must be identical for substitution per strict engineering criteria.

Request Quote (Ships tomorrow)