MIC6315-25D4U TR Equivalent & Substitute Parts

Part Overview

The MIC6315-25D4U TR is a single-channel power management supervisor IC manufactured by Microchip Technology, designed for reset and power-on reset applications in embedded systems. This component operates as an open drain or open collector supervisor with a 2.5V threshold voltage and 1.1s minimum reset timeout. The part is classified as obsolete, making equivalent and substitute parts necessary for new designs and ongoing production support. Substitute parts must maintain functional compatibility across voltage monitoring, reset behavior, output type, and operating temperature ranges while meeting current RoHS and REACH compliance requirements.

Substiute Parts

MIC6315-25D4U TR
Microchip TechnologyIn Stock: 1110MIC6315-25D4U TR Datasheet
MIC6315-25D4U TR
Current Part
MIC6315-25D4UY-TR
Microchip TechnologyIn Stock: 813MIC6315-25D4UY-TR Datasheet
MIC6315-25D4UY-TR
Direct
MAX6444US16L+T
Analog Devices Inc./Maxim IntegratedIn Stock: 3102MAX6444US16L+T Datasheet
MAX6444US16L+T
MFR Recommended
MAX6444US17L+T
Analog Devices Inc./Maxim IntegratedIn Stock: 956MAX6444US17L+T Datasheet
MAX6444US17L+T
MFR Recommended
MAX6444US23L+T
Analog Devices Inc./Maxim IntegratedIn Stock: 10221MAX6444US23L+T Datasheet
MAX6444US23L+T
MFR Recommended
MAX6444US29L+T
Analog Devices Inc./Maxim IntegratedIn Stock: 5381MAX6444US29L+T Datasheet
MAX6444US29L+T
MFR Recommended
MAX6444US44L+T
Analog Devices Inc./Maxim IntegratedIn Stock: 893MAX6444US44L+T Datasheet
MAX6444US44L+T
MFR Recommended
MAX6444US46L+T
Analog Devices Inc./Maxim IntegratedIn Stock: 4105MAX6444US46L+T Datasheet
MAX6444US46L+T
MFR Recommended
MAX6467US22D3+T
Analog Devices Inc./Maxim IntegratedIn Stock: 3647MAX6467US22D3+T Datasheet
MAX6467US22D3+T
MFR Recommended
MAX6467US26D3+T
Analog Devices Inc./Maxim IntegratedIn Stock: 3912MAX6467US26D3+T Datasheet
MAX6467US26D3+T
MFR Recommended
MAX6467US29D3+T
Analog Devices Inc./Maxim IntegratedIn Stock: 2215MAX6467US29D3+T Datasheet
MAX6467US29D3+T
MFR Recommended
MAX6467US33D3+T
Analog Devices Inc./Maxim IntegratedIn Stock: 1094MAX6467US33D3+T Datasheet
MAX6467US33D3+T
MFR Recommended
MAX6467US33D7+T
Analog Devices Inc./Maxim IntegratedIn Stock: 1170MAX6467US33D7+T Datasheet
MAX6467US33D7+T
MFR Recommended
MAX6467US44D3+T
Analog Devices Inc./Maxim IntegratedIn Stock: 7965MAX6467US44D3+T Datasheet
MAX6467US44D3+T
MFR Recommended
MAX6467US46D3+T
Analog Devices Inc./Maxim IntegratedIn Stock: 3754MAX6467US46D3+T Datasheet
MAX6467US46D3+T
MFR Recommended
MAX6805US26D3+T
Analog Devices Inc./Maxim IntegratedIn Stock: 994MAX6805US26D3+T Datasheet
MAX6805US26D3+T
MFR Recommended
MAX6805US29D3+T
Analog Devices Inc./Maxim IntegratedIn Stock: 5200MAX6805US29D3+T Datasheet
MAX6805US29D3+T
MFR Recommended
MAX6805US31D1+T
Analog Devices Inc./Maxim IntegratedIn Stock: 834MAX6805US31D1+T Datasheet
MAX6805US31D1+T
MFR Recommended
MAX6805US31D3+T
Analog Devices Inc./Maxim IntegratedIn Stock: 12127MAX6805US31D3+T Datasheet
MAX6805US31D3+T
MFR Recommended
MAX6805US46D3+T
Analog Devices Inc./Maxim IntegratedIn Stock: 2199MAX6805US46D3+T Datasheet
MAX6805US46D3+T
MFR Recommended

Key Parameters

Parameter MIC6315-25D4U TR
Manufacturer Microchip Technology
Category Power Management (PMIC)
Type Simple Reset/Power-On Reset
Number of Voltages Monitored 1
Voltage - Threshold 2.5V
Output Open Drain or Open Collector
Reset Active Low
Reset Timeout 1.1s Minimum
Operating Temperature -40°C ~ 85°C (TA)
Mounting Type Surface Mount
Package / Case TO-253-4, TO-253AA
Supplier Device Package SOT-143
RoHS Status RoHS non-compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
REACH Status REACH Unaffected
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution for the MIC6315-25D4U TR is determined by the following critical parameters:

Functional Equivalence Criteria:

  • Single-channel voltage monitoring capability
  • Open drain or open collector output configuration
  • Active low reset signal
  • Surface mount SOT-143 or SOT-143-4 package compatibility
  • Operating temperature range support (-40°C minimum to 85°C minimum)
  • Voltage threshold compatibility or application-specific selection

Compliance Criteria:

  • RoHS3 compliance status (required for new designs)
  • REACH unaffected status
  • MSL 1 rating

Substitute parts are grouped into two categories: direct functional equivalents from Microchip Technology and cross-manufacturer alternatives from Analog Devices Inc./Maxim Integrated. The Microchip MIC6315-25D4UY-TR maintains identical electrical specifications with active product status and RoHS3 compliance. Maxim Integrated MAX6444 and MAX6467 series parts provide functional substitution with varying voltage thresholds and reset timeout characteristics, allowing selection based on specific application requirements.

Parameter Comparison

Part Number Manufacturer Voltage Threshold Reset Timeout Operating Temp Range Output Type Package RoHS Status Product Status
MIC6315-25D4U TR Microchip Technology 2.5V 1.1s Min -40°C ~ 85°C Open Drain/Collector SOT-143 Non-compliant Obsolete
MIC6315-25D4UY-TR Microchip Technology 2.5V 1.1s Min -40°C ~ 85°C Open Drain/Collector SOT-143 ROHS3 Compliant Active
MAX6444US16L+T Analog Devices Inc./Maxim Integrated 1.575V 140ms Min -40°C ~ 85°C Open Drain/Collector SOT-143-4 ROHS3 Compliant Active
MAX6444US17L+T Analog Devices Inc./Maxim Integrated 1.665V 140ms Min -40°C ~ 85°C Open Drain/Collector SOT-143-4 ROHS3 Compliant Active
MAX6444US23L+T Analog Devices Inc./Maxim Integrated 2.313V 140ms Min -40°C ~ 85°C Open Drain/Collector SOT-143-4 ROHS3 Compliant Active
MAX6444US29L+T Analog Devices Inc./Maxim Integrated 2.925V 140ms Min -40°C ~ 85°C Open Drain/Collector SOT-143-4 ROHS3 Compliant Active
MAX6444US44L+T Analog Devices Inc./Maxim Integrated 4.375V 140ms Min -40°C ~ 85°C Open Drain/Collector SOT-143-4 ROHS3 Compliant Active
MAX6444US46L+T Analog Devices Inc./Maxim Integrated 4.625V 140ms Min -40°C ~ 85°C Open Drain/Collector SOT-143-4 ROHS3 Compliant Active
MAX6467US22D3+T Analog Devices Inc./Maxim Integrated 2.188V 150ms Min -40°C ~ 125°C Open Drain/Collector SOT-143-4 ROHS3 Compliant Active
MAX6467US26D3+T Analog Devices Inc./Maxim Integrated 2.625V 150ms Min -40°C ~ 125°C Open Drain/Collector SOT-143-4 ROHS3 Compliant Active
MAX6467US29D3+T Analog Devices Inc./Maxim Integrated 2.925V 150ms Min -40°C ~ 125°C Open Drain/Collector SOT-143-4 ROHS3 Compliant Active
MAX6805US26D3+T Analog Devices Inc./Maxim Integrated 2.625V 150ms Min -40°C ~ 125°C Open Drain/Collector SOT-143-4 ROHS3 Compliant Active
MAX6805US46D3+T Analog Devices Inc./Maxim Integrated 4.625V 150ms Min -40°C ~ 125°C Open Drain/Collector SOT-143-4 ROHS3 Compliant Active

Engineering Selection Recommendations

Primary Recommendation: MIC6315-25D4UY-TR

The MIC6315-25D4UY-TR is the direct functional equivalent from Microchip Technology. It maintains identical electrical specifications including 2.5V threshold voltage, 1.1s minimum reset timeout, and -40°C to 85°C operating temperature range. This part carries active product status and ROHS3 compliance, making it the preferred choice for designs requiring exact electrical compatibility with the obsolete MIC6315-25D4U TR.

Cross-Manufacturer Alternatives: Maxim Integrated MAX6444 and MAX6467 Series

Maxim Integrated supervisor ICs provide functional substitution with application-specific voltage threshold selection. The MAX6444 series offers reset timeout of 140ms minimum across -40°C to 85°C operating range, while the MAX6467 series extends operating temperature to 125°C with 150ms minimum reset timeout. All Maxim parts feature ROHS3 compliance and active product status.

Voltage threshold selection depends on application requirements:

  • MAX6444US23L+T and MAX6467US22D3+T provide thresholds near the original 2.5V specification
  • MAX6467US26D3+T and MAX6805US26D3+T offer 2.625V threshold with extended temperature range
  • Additional threshold options (1.575V to 4.625V) accommodate diverse power supply monitoring requirements

All substitute parts maintain open drain or open collector output configuration, active low reset signal, and SOT-143-4 package compatibility with the original TO-253-4 and TO-253AA footprint.

Frequently Asked Questions (FAQ)

Q: Can MIC6315-25D4UY-TR be used as a direct replacement for MIC6315-25D4U TR?

A: Yes. The MIC6315-25D4UY-TR is electrically and functionally identical to the MIC6315-25D4U TR, with the same 2.5V threshold voltage, 1.1s reset timeout, and operating temperature range. The primary difference is active product status and ROHS3 compliance. Pin configuration and package footprint are compatible.

Q: What is the difference between MAX6444 and MAX6467 series substitutes?

A: The MAX6467 series extends operating temperature to -40°C to 125°C compared to MAX6444's -40°C to 85°C range. MAX6467 also specifies 150ms minimum reset timeout versus MAX6444's 140ms. Both series provide multiple voltage threshold options and ROHS3 compliance. Selection depends on application temperature requirements.

Q: Are Maxim Integrated parts pin-compatible with the MIC6315-25D4U TR?

A: Yes. All substitute parts use SOT-143-4 package configuration compatible with the original TO-253-4 and TO-253AA footprint. Pin assignments for voltage monitoring input, reset output, VCC, and GND are functionally equivalent across all listed substitutes.

Q: How do voltage threshold differences affect substitution?

A: Voltage threshold determines the supply voltage level at which the supervisor triggers a reset signal. The original MIC6315-25D4U TR monitors 2.5V. Substitute parts with different thresholds (1.575V to 4.625V) are suitable only if the application's power supply voltage and reset trigger requirements match the selected threshold. Verify application schematic requirements before selecting a substitute with different threshold voltage.

Q: What compliance certifications apply to all substitute parts?

A: All active substitute parts listed carry ROHS3 compliance and REACH unaffected status. MSL rating is 1 (Unlimited) for all parts. The original MIC6315-25D4U TR is RoHS non-compliant; substitution with compliant parts is required for new designs and applications with compliance mandates.

Q: Can reset timeout differences between substitutes affect circuit operation?

A: Yes. The original MIC6315-25D4U TR specifies 1.1s minimum reset timeout, while MAX6444 series specifies 140ms and MAX6467 series specifies 150ms. Reset timeout determines how long the reset signal remains active after power supply stabilization. Applications requiring the longer 1.1s timeout must use MIC6315-25D4UY-TR or verify that shorter timeouts are acceptable for the target system.