MI-262-MX Equivalent & Substitute Parts Reference

Part Overview

The MI-262-MX from Vicor Corporation is an isolated module DC-DC converter featuring a single 15V, 5A output and an input range of 125V to 400V. The part is classified as obsolete, which necessitates the identification of interchangeable models to ensure ongoing system support and maintenance. Substitutes are considered based exclusively on matching electrical, mechanical, and regulatory parameters as provided.

Substiute Parts

MI-262-MX
Vicor CorporationIn Stock: 1145MI-262-MX Datasheet
MI-262-MX
Current Part
MI-262-MX-F1
Vicor CorporationIn Stock: 995MI-262-MX-F1 Datasheet
MI-262-MX-F1
Similar

Key Parameters

Parameter MI-262-MX Value
Manufacturer Vicor Corporation
Description DC DC CONVERTER 15V 75W
Series MI-200™ (75W)
Product Status Obsolete
Type Isolated Module
Number of Outputs 1
Voltage - Input (Min) 125V
Voltage - Input (Max) 400V
Voltage - Output 1 15V
Current - Output (Max) 5A
Power (Watts) 75 W
Voltage - Isolation 3 kV
Applications ITE (Commercial)
Features Remote On/Off, OCP, OTP, OVP
Operating Temperature -55°C ~ 85°C
Efficiency 90%
Mounting Type Through Hole
Package / Case Full Brick
Size / Dimension 4.20" L x 2.40" W x 0.50" H (106.7mm x 61.0mm x 12.7mm)
RoHS Status RoHS non-compliant
REACH Status REACH Unaffected
ECCN EAR99
HTSUS 8504.40.9580

Substitute Part Grouping Explanation

Substitute part evaluation for the MI-262-MX is strictly defined by an exact match in core parameters: manufacturer, series, type, number of outputs, electrical ratings (input voltage range, output voltage and current, power, isolation voltage), application (ITE Commercial), features, operating temperature, efficiency, mounting, package/case, and compliance details. Only products matching these constraints are eligible for substitution within this product category.

Parameter Comparison

Parameter MI-262-MX MI-262-MX-F1
Manufacturer Vicor Corporation Vicor Corporation
Description DC DC CONVERTER 15V 75W DC DC CONVERTER 15V 75W
Series MI-200™ (75W) MI-200™ (75W)
Product Status Obsolete Active
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 125V 125V
Voltage - Input (Max) 400V 400V
Voltage - Output 1 15V 15V
Current - Output (Max) 5A 5A
Power (Watts) 75 W 75 W
Voltage - Isolation 3 kV 3 kV
Applications ITE (Commercial) ITE (Commercial)
Features Remote On/Off, OCP, OTP, OVP Remote On/Off, OCP, OTP, OVP
Operating Temperature -55°C ~ 85°C -55°C ~ 85°C
Efficiency 90% 90%
Mounting Type Through Hole Through Hole
Package / Case Full Brick Full Brick
Size / Dimension 4.20" L x 2.40" W x 0.50" H (106.7mm x 61.0mm x 12.7mm) 4.20" L x 2.40" W x 0.75" H (106.7mm x 61.0mm x 19.0mm)
RoHS Status RoHS non-compliant RoHS non-compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

The MI-262-MX is classified as obsolete, while the MI-262-MX-F1 is active. Both are RoHS non-compliant and share the same regulatory and certification status. The only dimensional variation is in height (MI-262-MX: 0.50" H; MI-262-MX-F1: 0.75" H), with all other parameters remaining consistent. Selection within this group should be strictly based on required product lifecycle status and physical/mechanical constraints as provided.

Frequently Asked Questions (FAQ)

Q1: What are the essential criteria for substituting the MI-262-MX DC-DC converter?
A1: Key substitution criteria include matching input/output voltages, current, output power, isolation voltage, temperature range, package, features, mounting type, compliance status, and dimensional compatibility.

Q2: Are the MI-262-MX and MI-262-MX-F1 footprint and pinout compatible?
A2: Both parts use the Full Brick package with the same length and width. The only difference is the height. There are no further details on pinout provided in the input.

Q3: Is there a difference in regulatory compliance between the MI-262-MX and its substitute?
A3: Both parts are RoHS non-compliant, REACH unaffected, EAR99 classified, and share the same HTSUS code.

Q4: Does the change in part status affect the use of these modules?
A4: The MI-262-MX is obsolete, while the MI-262-MX-F1 is active. Product status is a key factor in engineering selection when ensuring ongoing support and supply continuity.

Q5: Does the change in module height between MI-262-MX and MI-262-MX-F1 impact interchangeability?
A5: The only dimensional difference is height (0.50" vs 0.75"). All other dimensions are consistent as provided. The suitability depends on the application’s mechanical clearance and design requirements.

Request Quote (Ships tomorrow)