MI-262-MX Equivalent & Substitute Parts Reference
Part Overview
The MI-262-MX from Vicor Corporation is an isolated module DC-DC converter featuring a single 15V, 5A output and an input range of 125V to 400V. The part is classified as obsolete, which necessitates the identification of interchangeable models to ensure ongoing system support and maintenance. Substitutes are considered based exclusively on matching electrical, mechanical, and regulatory parameters as provided.
Substiute Parts
Key Parameters
| Parameter | MI-262-MX Value |
|---|---|
| Manufacturer | Vicor Corporation |
| Description | DC DC CONVERTER 15V 75W |
| Series | MI-200™ (75W) |
| Product Status | Obsolete |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 125V |
| Voltage - Input (Max) | 400V |
| Voltage - Output 1 | 15V |
| Current - Output (Max) | 5A |
| Power (Watts) | 75 W |
| Voltage - Isolation | 3 kV |
| Applications | ITE (Commercial) |
| Features | Remote On/Off, OCP, OTP, OVP |
| Operating Temperature | -55°C ~ 85°C |
| Efficiency | 90% |
| Mounting Type | Through Hole |
| Package / Case | Full Brick |
| Size / Dimension | 4.20" L x 2.40" W x 0.50" H (106.7mm x 61.0mm x 12.7mm) |
| RoHS Status | RoHS non-compliant |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute part evaluation for the MI-262-MX is strictly defined by an exact match in core parameters: manufacturer, series, type, number of outputs, electrical ratings (input voltage range, output voltage and current, power, isolation voltage), application (ITE Commercial), features, operating temperature, efficiency, mounting, package/case, and compliance details. Only products matching these constraints are eligible for substitution within this product category.
Parameter Comparison
| Parameter | MI-262-MX | MI-262-MX-F1 |
|---|---|---|
| Manufacturer | Vicor Corporation | Vicor Corporation |
| Description | DC DC CONVERTER 15V 75W | DC DC CONVERTER 15V 75W |
| Series | MI-200™ (75W) | MI-200™ (75W) |
| Product Status | Obsolete | Active |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 125V | 125V |
| Voltage - Input (Max) | 400V | 400V |
| Voltage - Output 1 | 15V | 15V |
| Current - Output (Max) | 5A | 5A |
| Power (Watts) | 75 W | 75 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | Remote On/Off, OCP, OTP, OVP | Remote On/Off, OCP, OTP, OVP |
| Operating Temperature | -55°C ~ 85°C | -55°C ~ 85°C |
| Efficiency | 90% | 90% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Full Brick | Full Brick |
| Size / Dimension | 4.20" L x 2.40" W x 0.50" H (106.7mm x 61.0mm x 12.7mm) | 4.20" L x 2.40" W x 0.75" H (106.7mm x 61.0mm x 19.0mm) |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
The MI-262-MX is classified as obsolete, while the MI-262-MX-F1 is active. Both are RoHS non-compliant and share the same regulatory and certification status. The only dimensional variation is in height (MI-262-MX: 0.50" H; MI-262-MX-F1: 0.75" H), with all other parameters remaining consistent. Selection within this group should be strictly based on required product lifecycle status and physical/mechanical constraints as provided.
Frequently Asked Questions (FAQ)
Q1: What are the essential criteria for substituting the MI-262-MX DC-DC converter?
A1: Key substitution criteria include matching input/output voltages, current, output power, isolation voltage, temperature range, package, features, mounting type, compliance status, and dimensional compatibility.
Q2: Are the MI-262-MX and MI-262-MX-F1 footprint and pinout compatible?
A2: Both parts use the Full Brick package with the same length and width. The only difference is the height. There are no further details on pinout provided in the input.
Q3: Is there a difference in regulatory compliance between the MI-262-MX and its substitute?
A3: Both parts are RoHS non-compliant, REACH unaffected, EAR99 classified, and share the same HTSUS code.
Q4: Does the change in part status affect the use of these modules?
A4: The MI-262-MX is obsolete, while the MI-262-MX-F1 is active. Product status is a key factor in engineering selection when ensuring ongoing support and supply continuity.
Q5: Does the change in module height between MI-262-MX and MI-262-MX-F1 impact interchangeability?
A5: The only dimensional difference is height (0.50" vs 0.75"). All other dimensions are consistent as provided. The suitability depends on the application’s mechanical clearance and design requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts