Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts Reference: MGS301215
Part Overview
The MGS301215, manufactured by Cosel USA, Inc., is an isolated module DC-DC converter, designed to deliver a single 15V output at 2A with a 9V to 18V input voltage range. The product features remote on/off capability, over-current protection (OCP), and over-voltage protection (OVP), with 1.5 kV isolation and 90% efficiency. With an active product status and RoHS3 compliance, substitution may be required for procurement flexibility, inventory management, or compatibility across system designs. Only parts matching the strict electrical and mechanical criteria can be considered suitable alternatives.
Substiute Parts
Key Parameters
| Parameter | MGS301215 |
|---|---|
| Manufacturer | Cosel USA, Inc. |
| Category | |
| Packaging | Box |
| Series | MGS (30W) |
| Product Status | Active |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 9V |
| Voltage - Input (Max) | 18V |
| Voltage - Output 1 | 15V |
| Current - Output (Max) | 2A |
| Voltage - Isolation | 1.5 kV |
| Applications | ITE (Commercial) |
| Features | Remote On/Off, OCP, OVP |
| Operating Temperature | -40°C ~ 85°C (With Derating) |
| Efficiency | 90% |
| Mounting Type | Through Hole |
| Package / Case | 6-DIP Module |
| Size / Dimension | 2.00" L x 1.00" W x 0.39" H (50.8mm x 25.4mm x 9.9mm) |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | Not Applicable |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute parts are grouped based on strict equivalence of core electrical and mechanical parameters. Each alternative must match the following criteria: isolated module type, 15V output voltage at 2A, single output configuration, input range between 9V and 18V, 1.5 kV isolation voltage, through hole mounting, similar 6-DIP module case, and RoHS3 compliance. Product status must be active and suitable for ITE (Commercial) applications. This ensures form, fit, and basic functional compatibility without deviation from supplied specifications.
Parameter Comparison
| Parameter | MGS301215 (Cosel USA, Inc.) | SKM30A-15 (MEAN WELL USA Inc.) |
|---|---|---|
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 9V | 9V |
| Voltage - Input (Max) | 18V | 18V |
| Voltage - Output 1 | 15V | 15V |
| Current - Output (Max) | 2A | 2A |
| Voltage - Isolation | 1.5 kV | 1.5 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | Remote On/Off, OCP, OVP | Remote On/Off, OCP, OVP, SCP |
| Operating Temperature | -40°C ~ 85°C (With Derating) | -40°C ~ 75°C (With Derating) |
| Efficiency | 90% | 89.5% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 6-DIP Module | 6-DIP Module |
| Size / Dimension | 2.00" L x 1.00" W x 0.39" H (50.8mm x 25.4mm x 9.9mm) | 2.00" L x 1.00" W x 0.44" H (50.8mm x 25.4mm x 11.2mm) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
Both MGS301215 and SKM30A-15 are active, RoHS3 compliant DC-DC converter isolated modules, listed under ECCN EAR99 and HTSUS 8504.40.9580. Selection between these options for commercial ITE applications can be made strictly on the basis of compliance status and inventory availability. Both options adhere to environmental, safety, and export control standards as stated.
Frequently Asked Questions (FAQ)
Q1: What determines if SKM30A-15 can substitute for MGS301215?
A1: Equivalence requires matching isolated module type, identical output voltage and current (15V/2A), single output, input voltage range (9V–18V), isolation voltage (1.5 kV), identical mounting type and package, and RoHS3 compliance.
Q2: Are there any mechanical differences in the through hole package?
A2: Both parts use the 6-DIP module footprint; their lengths and widths match, with a slight difference in height (MGS301215: 0.39"; SKM30A-15: 0.44").
Q3: Is environmental compliance identical for both parts?
A3: Yes. Both are RoHS3 compliant, listed under ECCN EAR99 and HTSUS 8504.40.9580.
Q4: Do operating temperatures differ?
A4: MGS301215 operates from -40°C to 85°C (with derating) while SKM30A-15 specifies -40°C to 75°C (with derating).
Q5: Are functional features fully matched?
A5: Both feature remote on/off, OCP, and OVP; SKM30A-15 also lists SCP (short circuit protection).
Q6: Can either part be selected for ITE (Commercial) systems?
A6: Yes. Both are designated for ITE (Commercial) applications as per provided information.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts