MF010-0-LC4 Oxygen Sensor Equivalent & Substitute Parts

Part Overview

The MF010-0-LC4 is an oxygen sensor manufactured by Honeywell Sensing and Productivity Solutions, designed for oxygen concentration measurement in the range of 1 mbar to 1000 mbar with 4mA to 20mA output signal. This sensor operates at 24V supply voltage with 500mA current consumption and delivers ±2% accuracy across an operating temperature range of -10°C to 50°C.

The MF010-0-LC4 has reached obsolete product status. Identifying equivalent substitute parts is necessary to maintain system functionality, ensure supply chain continuity, and support ongoing applications where this sensor is currently deployed.

Substiute Parts

MF010-0-LC4
Honeywell Sensing and Productivity SolutionsIn Stock: 830MF010-0-LC4 Datasheet
MF010-0-LC4
Current Part
OXY-FLEX-1-H
SST Sensing Ltd.In Stock: 2775OXY-FLEX-1-H Datasheet
OXY-FLEX-1-H
Similar

Key Parameters

Parameter Value
Manufacturer Part Number MF010-0-LC4
Manufacturer Honeywell Sensing and Productivity Solutions
Product Type Oxygen Sensor
Oxygen Range 1 mbar ~ 1000 mbar
Output Signal 4mA ~ 20mA
Accuracy ±2%
Voltage - Supply 22.8V ~ 25.2V
Current - Supply 500mA
Operating Temperature -10°C ~ 50°C
Product Status Obsolete
RoHS Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the MF010-0-LC4 is determined by the following critical parameters that must be maintained or exceeded in the replacement component:

Mandatory Compatibility Parameters:

  • Output signal type: 4mA ~ 20mA (current loop output)
  • Supply voltage range: Must accommodate 22.8V ~ 25.2V nominal 24V operation
  • Supply current: 500mA maximum
  • Sensor type: Oxygen measurement capability
  • Measurement range: 1 mbar ~ 1000 mbar oxygen concentration
  • Moisture Sensitivity Level: MSL 1 (Unlimited)
  • Regulatory compliance: RoHS Compliant or equivalent

Performance Parameters (Substitution Allowed if Equal or Better):

  • Accuracy: ±2% or better
  • Operating temperature range: Must cover -10°C to 50°C minimum

The OXY-FLEX-1-H from SST Sensing Ltd. meets all mandatory compatibility parameters and exceeds performance specifications in accuracy (±1% versus ±2%) and operating temperature range (-10°C to 85°C versus -10°C to 50°C).

Parameter Comparison

Parameter MF010-0-LC4 (Honeywell) OXY-FLEX-1-H (SST Sensing) Compatibility Status
Manufacturer Part Number MF010-0-LC4 OXY-FLEX-1-H Different
Product Type Oxygen Sensor Oxygen Sensor Compatible
Output Signal 4mA ~ 20mA 4mA ~ 20mA Compatible
Accuracy ±2% ±1% Substitute Exceeds
Voltage - Supply 22.8V ~ 25.2V 24V Compatible
Current - Supply 500mA 500mA Compatible
Operating Temperature -10°C ~ 50°C -10°C ~ 85°C Substitute Exceeds
RoHS Status RoHS Compliant ROHS3 Compliant Compatible
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) Compatible
ECCN EAR99 EAR99 Compatible
HTSUS 9027.10.2000 9027.10.2000 Compatible

Engineering Selection Recommendations

The OXY-FLEX-1-H is a direct functional substitute for the obsolete MF010-0-LC4. Both components share identical electrical interface specifications (4mA ~ 20mA output, 24V supply, 500mA current), identical regulatory classification (EAR99), and identical tariff codes (HTSUS 9027.10.2000).

The OXY-FLEX-1-H maintains active product status with 2700 units in stock, ensuring supply availability. The substitute component demonstrates superior performance characteristics: ±1% accuracy compared to ±2%, and extended operating temperature range of -10°C to 85°C compared to -10°C to 50°C. Both components carry equivalent moisture sensitivity ratings (MSL 1, Unlimited) and comply with RoHS standards.

The OXY-FLEX-1-H is supplied in bulk packaging, whereas the MF010-0-LC4 was supplied in box packaging. This packaging difference does not affect functional compatibility or electrical performance.

Frequently Asked Questions (FAQ)

Q: Can the OXY-FLEX-1-H directly replace the MF010-0-LC4 in existing installations?

A: Yes. Both sensors provide identical 4mA ~ 20mA current loop output, operate at 24V supply voltage with 500mA current consumption, and measure oxygen concentration across the 1 mbar to 1000 mbar range. No signal conditioning or interface modifications are required.

Q: What are the key differences between these two sensors?

A: The OXY-FLEX-1-H provides improved accuracy (±1% versus ±2%) and extended operating temperature range (-10°C to 85°C versus -10°C to 50°C). Both sensors are functionally equivalent for the specified operating conditions of the MF010-0-LC4.

Q: Does the packaging difference (box versus bulk) affect compatibility?

A: No. Packaging format does not affect electrical performance, signal output, or functional compatibility. Packaging differences relate only to storage, handling, and logistics.

Q: Are both sensors RoHS compliant?

A: Yes. The MF010-0-LC4 is RoHS Compliant, and the OXY-FLEX-1-H is ROHS3 Compliant. Both meet current regulatory requirements for hazardous substance restrictions.

Q: What is the supply status of each sensor?

A: The MF010-0-LC4 is obsolete with 817 units in stock. The OXY-FLEX-1-H is active with 2700 units in stock, providing superior long-term supply availability.

Q: Are the export control classifications identical?

A: Yes. Both sensors carry ECCN classification EAR99 and HTSUS tariff code 9027.10.2000, indicating identical export control and customs treatment.