The MDA-V-15-R is a 15 A, 250 V AC ceramic cartridge fuse manufactured by Eaton - Electronics Division. This through-hole mounted fuse is designed for general-purpose circuit protection applications requiring slow-blow response characteristics. The fuse is housed in a 3AB, 3AG package format with dimensions of 1/4" x 1-1/4" (6.76mm x 32.82mm). The product maintains Active status and is RoHS3 compliant. Equivalent and substitute parts are identified to support procurement flexibility, inventory management, and supply chain continuity for applications requiring identical or functionally compatible ceramic fuse cartridges.

Substiute Parts

MDA-V-15-R
Eaton - Electronics DivisionIn Stock: 793MDA-V-15-R Datasheet
MDA-V-15-R
Current Part
BK/MDA-V-15-R
Eaton - Electronics DivisionIn Stock: 2100BK/MDA-V-15-R Datasheet
BK/MDA-V-15-R
Direct
0325015.MXP
Littelfuse Inc.In Stock: 94730325015.MXP Datasheet
0325015.MXP
Similar

Key Parameters

Parameter Value
Current Rating 15 A
Voltage Rating - AC 250 V
Fuse Type Cartridge, Ceramic
Package / Case 3AB, 3AG, 1/4" x 1-1/4" (Axial)
Response Time Slow Blow
Mounting Type Through Hole
Breaking Capacity @ Rated Voltage 750 A
Melting I²t 336.82
DC Cold Resistance 0.00553 Ohms
Approval Agency CE, CSA, UL
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitute parts for the MDA-V-15-R are classified based on strict electrical and mechanical parameter alignment. The substitution logic is structured as follows:

Direct Equivalent Classification: Parts classified as direct equivalents maintain identical specifications across all critical parameters: 15 A current rating, 250 V AC voltage rating, ceramic cartridge fuse type, 3AB/3AG package format, slow-blow response, through-hole mounting, 750 A breaking capacity, and RoHS3 compliance. These parts are interchangeable without circuit redesign or application re-evaluation.

Compatible Substitute Classification: Parts classified as compatible substitutes share the core electrical characteristics (15 A, 250 V AC, ceramic cartridge, slow-blow response, through-hole mounting, 3AB/3AG package) but may differ in secondary parameters such as DC voltage rating, breaking capacity, melting I²t value, or operating temperature range. These parts are suitable for applications where the differing parameters do not conflict with circuit requirements.

Key Parameters Determining Substitution:

  • Current Rating: 15 A (mandatory match)
  • Voltage Rating - AC: 250 V (mandatory match)
  • Fuse Type: Cartridge, Ceramic (mandatory match)
  • Package / Case: 3AB, 3AG, 1/4" x 1-1/4" (mandatory match)
  • Response Time: Slow Blow (mandatory match)
  • Mounting Type: Through Hole (mandatory match)

Parameter Comparison

Parameter MDA-V-15-R (Eaton) BK/MDA-V-15-R (Eaton) 0325015.MXP (Littelfuse)
Manufacturer Eaton - Electronics Division Eaton - Electronics Division Littelfuse Inc.
Current Rating (Amps) 15 A 15 A 15 A
Voltage Rating - AC 250 V 250 V 250 V
Voltage Rating - DC Not specified Not specified 60 V
Fuse Type Cartridge, Ceramic Cartridge, Ceramic Cartridge, Ceramic
Package / Case 3AB, 3AG, 1/4" x 1-1/4" 3AB, 3AG, 1/4" x 1-1/4" 3AB, 3AG, 1/4" x 1-1/4"
Response Time Slow Blow Slow Blow Slow Blow
Mounting Type Through Hole Through Hole Through Hole
Breaking Capacity @ Rated Voltage 750 A 750 A 400 A AC, 500 A DC
Melting I²t 336.82 336.82 245
DC Cold Resistance (Ohms) 0.00553 0.00553 0.005
Operating Temperature Not specified Not specified -55°C ~ 125°C
Approval Agency CE, CSA, UL CE, CSA, UL CE, CSA, K-MARK, PSE, UL
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
Series MDA MDA 325
Product Status Active Active Active

Engineering Selection Recommendations

BK/MDA-V-15-R (Eaton - Electronics Division): This part is classified as a direct equivalent to the MDA-V-15-R. Both parts are manufactured by Eaton - Electronics Division and maintain identical electrical and mechanical specifications, including 15 A current rating, 250 V AC voltage rating, 750 A breaking capacity, 336.82 melting I²t, and 0.00553 Ohms DC cold resistance. Both parts carry Active product status and hold CE, CSA, and UL certifications. Both are RoHS3 compliant. The BK/MDA-V-15-R designation represents a variant packaging or distribution channel designation within the same product family. This part is suitable for direct substitution in all applications where the MDA-V-15-R is specified.

0325015.MXP (Littelfuse Inc.): This part is classified as a compatible substitute. The 0325015.MXP shares the core electrical and mechanical characteristics with the MDA-V-15-R: 15 A current rating, 250 V AC voltage rating, ceramic cartridge fuse type, 3AB/3AG package format, slow-blow response, and through-hole mounting. Both parts are Active products with RoHS3 compliance and hold CE, CSA, and UL certifications. The 0325015.MXP differs in the following parameters: breaking capacity (400 A AC, 500 A DC versus 750 A), melting I²t (245 versus 336.82), DC cold resistance (0.005 Ohms versus 0.00553 Ohms), and specified operating temperature range (-55°C ~ 125°C). The 0325015.MXP also includes DC voltage rating (60 V) and additional certifications (K-MARK, PSE). This part is suitable for substitution in applications where the lower breaking capacity and melting I²t values do not conflict with circuit protection requirements.

Frequently Asked Questions (FAQ)

Q: Can BK/MDA-V-15-R be used as a direct replacement for MDA-V-15-R? A: Yes. The BK/MDA-V-15-R is a direct equivalent. Both parts are manufactured by Eaton - Electronics Division and maintain identical specifications across all critical electrical and mechanical parameters, including current rating, voltage rating, breaking capacity, melting I²t, and resistance values. No circuit modification is required.

Q: What are the key differences between MDA-V-15-R and 0325015.MXP? A: Both parts share identical current rating (15 A), AC voltage rating (250 V), fuse type (ceramic cartridge), package format (3AB/3AG), response time (slow-blow), and mounting type (through-hole). The 0325015.MXP differs in breaking capacity (400 A AC, 500 A DC versus 750 A), melting I²t (245 versus 336.82), DC cold resistance (0.005 Ohms versus 0.00553 Ohms), and includes a specified operating temperature range (-55°C ~ 125°C). The 0325015.MXP also includes DC voltage rating (60 V) and additional certifications (K-MARK, PSE).

Q: Is the 0325015.MXP suitable for all applications using MDA-V-15-R? A: The 0325015.MXP is suitable for applications where the lower breaking capacity (400 A AC, 500 A DC) and lower melting I²t value (245) do not conflict with circuit protection requirements. Applications requiring the full 750 A breaking capacity or higher melting I²t value of the MDA-V-15-R should not use the 0325015.MXP as a substitute.

Q: Are all substitute parts RoHS3 compliant? A: Yes. The MDA-V-15-R, BK/MDA-V-15-R, and 0325015.MXP are all RoHS3 compliant.

Q: What certifications do these fuses hold? A: The MDA-V-15-R and BK/MDA-V-15-R hold CE, CSA, and UL certifications. The 0325015.MXP holds CE, CSA, K-MARK, PSE, and UL certifications.

Q: Are the physical dimensions identical across all three parts? A: The MDA-V-15-R and BK/MDA-V-15-R have identical dimensions (0.266" Dia x 1.292" L / 6.76mm x 32.82mm). The 0325015.MXP has slightly different dimensions (0.275" Dia x 1.288" L / 6.99mm x 32.72mm). Both package formats are 3AB/3AG and are mechanically compatible with standard through-hole fuse holders designed for this package type.

Q: What is the difference between the MDA-V-15-R and BK/MDA-V-15-R part numbers? A: Both parts are manufactured by Eaton - Electronics Division and are electrically and mechanically identical. The BK/ prefix designation represents a variant in packaging, distribution channel, or internal product classification. The parts are interchangeable.

Q: Can I use 0325015.MXP in a circuit designed for MDA-V-15-R if the breaking capacity is not a critical factor? A: The 0325015.MXP can be used in applications where the lower breaking capacity (400 A AC, 500 A DC) and lower melting I²t value (245) are acceptable for the circuit protection scheme. The core electrical characteristics (15 A, 250 V AC, slow-blow ceramic cartridge) are identical. Verify that the application does not require the higher breaking capacity or melting I²t value of the MDA-V-15-R before substitution.