MBRT120150R Equivalent & Substitute Parts Reference

Part Overview

The MBRT120150R, manufactured by GeneSiC Semiconductor, is a Schottky diode array configured as 1 Pair Common Anode, rated for 150 V DC Reverse Voltage and 60A Average Rectified Current per diode, supplied in a Three Tower chassis mount package. The device is classified as Obsolete, presenting an immediate requirement for identifying suitable, in-production substitutes to support ongoing applications and ensure continuity of supply in the diodes, rectifiers category.

Substiute Parts

MBRT120150R
GeneSiC SemiconductorIn Stock: 920MBRT120150R Datasheet
MBRT120150R
Current Part
MBRT120200R
GeneSiC SemiconductorIn Stock: 1081MBRT120200R Datasheet
MBRT120200R
Direct

Key Parameters

ParameterValue
Manufacturer Part NumberMBRT120150R
ManufacturerGeneSiC Semiconductor
CategoryDiodes, Rectifiers
Diode Configuration1 Pair Common Anode
TechnologySchottky
Voltage - DC Reverse (Vr) (Max)150 V
Current - Average Rectified (Io) (per Diode)60A
Voltage - Forward (Vf) (Max) @ If880 mV @ 60A
SpeedFast Recovery =< 500ns, > 200mA (Io)
Current - Reverse Leakage @ Vr1 mA @ 150 V
Operating Temperature - Junction-55°C ~ 150°C
Mounting TypeChassis Mount
Package / CaseThree Tower
Supplier Device PackageThree Tower
RoHS StatusRoHS Compliant
Moisture Sensitivity Level (MSL)1 (Unlimited)
ECCNEAR99

Substitute Part Grouping Explanation

Substitution for the MBRT120150R is restricted to parts matching the following mandatory specifications: diode configuration (1 Pair Common Anode), technology (Schottky), average rectified current per diode (60A), recovery speed (Fast Recovery =< 500ns, >200mA Io), package/case (Three Tower chassis mount), voltage rating (DC Reverse), forward voltage characteristics, reverse leakage current at voltage, operating temperature, compliance with RoHS directive, and MSL. All listed parameters must be supplied exactly as provided to ensure form, fit, and functional equivalence within diodes, rectifiers category applications.

Parameter Comparison

ParameterMBRT120150RMBRT120200R
Manufacturer Part NumberMBRT120150RMBRT120200R
ManufacturerGeneSiC SemiconductorGeneSiC Semiconductor
CategoryDiodes, RectifiersDiodes, Rectifiers
Diode Configuration1 Pair Common Anode1 Pair Common Anode
TechnologySchottkySchottky
Voltage - DC Reverse (Vr) (Max)150 V200 V
Current - Average Rectified (Io) (per Diode)60A60A
Voltage - Forward (Vf) (Max) @ If880 mV @ 60A920 mV @ 60A
SpeedFast Recovery =< 500ns, > 200mA (Io)Fast Recovery =< 500ns, > 200mA (Io)
Current - Reverse Leakage @ Vr1 mA @ 150 V1 mA @ 200 V
Operating Temperature - Junction-55°C ~ 150°C-55°C ~ 150°C
Mounting TypeChassis MountChassis Mount
Package / CaseThree TowerThree Tower
Supplier Device PackageThree TowerThree Tower
RoHS StatusRoHS CompliantRoHS Compliant
Moisture Sensitivity Level (MSL)1 (Unlimited)1 (Unlimited)
ECCNEAR99EAR99

Engineering Selection Recommendations

Selection of MBRT120200R is supported due to its active product status and full RoHS compliance, matching the original MBRT120150R’s form factor, mounting style, diode configuration, and all compliance and certification fields (MSL=1, ECCN=EAR99). The substitute’s parameters align with the original in all mandatory electrical and mechanical facets apart from maximum reverse voltage and forward voltage, both of which are strictly identified in this guide.

Frequently Asked Questions (FAQ)

Q1: What are the primary criteria for substituting MBRT120150R in diodes, rectifiers applications?
A1: Substitution requires matching diode configuration, technology, current rating, recovery speed, mounting type, package/case, operating temperature, and compliance certifications.

Q2: Is package compatibility ensured when replacing MBRT120150R with MBRT120200R?
A2: Both parts use the Three Tower chassis mount package and supplier device package, ensuring direct mechanical compatibility.

Q3: Are there differences in electrical ratings between MBRT120150R and MBRT120200R?
A3: The substitute MBRT120200R has an increased DC Reverse Voltage (200 V vs 150 V) and marginally higher forward voltage (920 mV vs 880 mV @ 60A).

Q4: Does the substitute meet the same operating temperature and compliance criteria?
A4: Both devices support an operating junction temperature range of -55°C ~ 150°C and share RoHS and MSL certifications.

Q5: What is the consequence of using a substitute part with a higher DC Reverse Voltage rating?
A5: As per provided parameters, substitution is determined strictly by explicit comparison; increased reverse voltage is noted in the data table.

Q6: What supply chain considerations exist for MBRT120150R and MBRT120200R?
A6: MBRT120150R is obsolete, while MBRT120200R is active and available in bulk packaging, supporting sourcing continuity.

Request Quote (Ships tomorrow)