Equivalent & Substitute Parts for MBR60040CTRL Diode Module

Part Overview

The MBR60040CTRL is a GeneSiC Semiconductor Schottky diode module categorized under Diodes, Rectifiers. It features a common anode diode array configuration, supporting a maximum DC reverse voltage of 40 V and an average rectified current of 300A per diode, housed in a chassis mount Twin Tower package. This module is currently classified as Obsolete, necessitating identification of alternative models for continued system maintenance or new designs.

Substiute Parts

MBR60040CTRL
GeneSiC SemiconductorIn Stock: 939MBR60040CTRL Datasheet
MBR60040CTRL
Current Part
MBR60040CTR
GeneSiC SemiconductorIn Stock: 845MBR60040CTR Datasheet
MBR60040CTR
Similar

Key Parameters

Parameter Value
Manufacturer GeneSiC Semiconductor
Category Diodes, Rectifiers
Diode Configuration 1 Pair Common Anode
Technology Schottky
Voltage - DC Reverse (Vr) (Max) 40 V
Current - Average Rectified (Io) (per Diode) 300A
Voltage - Forward (Vf) (Max) @ If 600 mV @ 300 A
Speed Fast Recovery =< 500ns, > 200mA (Io)
Current - Reverse Leakage @ Vr 5 mA @ 40 V
Operating Temperature - Junction -55°C ~ 150°C
Mounting Type Chassis Mount
Package / Case Twin Tower
Supplier Device Package Twin Tower
Moisture Sensitivity Level (MSL) 1 (Unlimited)
ECCN EAR99
HTSUS 8541.10.0080
Product Status Obsolete

Substitute Part Grouping Explanation

Substitute models for the MBR60040CTRL are identified strictly by matching the following key parameters: manufacturer, category, diode configuration, technology, voltage rating, current rating, electrical speed, reverse leakage, operating temperature range, mounting type, package/case, moisture sensitivity level, ECCN, and HTSUS designation. Substitution is permitted only when these specific characteristics align directly between the main part and candidate substitutes.

Parameter Comparison

Parameter MBR60040CTRL MBR60040CTR
Manufacturer GeneSiC Semiconductor GeneSiC Semiconductor
Category Diodes, Rectifiers Diodes, Rectifiers
Diode Configuration 1 Pair Common Anode 1 Pair Common Anode
Technology Schottky Schottky
Voltage - DC Reverse (Vr) (Max) 40 V 40 V
Current - Average Rectified (Io) (per Diode) 300A 300A
Voltage - Forward (Vf) (Max) @ If 600 mV @ 300 A 750 mV @ 300 A
Speed Fast Recovery =< 500ns, > 200mA (Io) Fast Recovery =< 500ns, > 200mA (Io)
Current - Reverse Leakage @ Vr 5 mA @ 40 V 1 mA @ 20 V
Operating Temperature - Junction -55°C ~ 150°C -55°C ~ 150°C
Mounting Type Chassis Mount Chassis Mount
Package / Case Twin Tower Twin Tower
Supplier Device Package Twin Tower Twin Tower
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
ECCN EAR99 EAR99
HTSUS 8541.10.0080 8541.10.0080
Product Status Obsolete Active

Engineering Selection Recommendations

Select the MBR60040CTR as an alternative to the MBR60040CTRL based on equivalent manufacturer, diode configuration, technology, voltage, current ratings, mounting method, and package. The MBR60040CTR is listed as Active and RoHS Compliant, fulfilling basic compliance criteria and regulatory requirements as specified, for applications matching the outlined electrical and package attributes.

Frequently Asked Questions (FAQ)

Q1: Which key parameters must match when substituting the MBR60040CTRL?
A1: Substitution is based solely on manufacturer, diode configuration, technology, voltage rating, current rating, recovery speed, leakage specifications, operating temperature, mounting type, package/case, moisture sensitivity, ECCN, and HTSUS codes.

Q2: Is the MBR60040CTR compatible with the original chassis and circuit layout?
A2: Both the MBR60040CTRL and MBR60040CTR use the Twin Tower chassis mount package, enabling mechanical compatibility within the same system form factor.

Q3: Does the substitute part meet compliance requirements?
A3: The MBR60040CTR is specified as RoHS Compliant and maintains the same ECCN and HTSUS classifications as the original, ensuring regulatory equivalence.

Q4: Are there differences in electrical performance that need consideration?
A4: The main difference is the forward voltage rating, with MBR60040CTRL at 600 mV @ 300 A and MBR60040CTR at 750 mV @ 300 A. All other key values are provided above; selection should align strictly with application electrical tolerances where those parameters are critical.

Q5: Why is substitution necessary for the MBR60040CTRL?
A5: The MBR60040CTRL is listed as Obsolete, requiring engineers to use a substitute part that fulfills the exact provided technical and regulatory parameters.

Request Quote (Ships tomorrow)