Request Quote
(Ships tomorrow)
MAX800LCPE Equivalent & Substitute Parts
Part Overview
The MAX800LCPE is a supervisory circuit from Analog Devices Inc./Maxim Integrated designed for power management applications. It functions as a battery backup circuit with single-channel voltage monitoring and configurable reset output. The device is classified as obsolete, making identification of functionally equivalent alternatives necessary for ongoing system support and component procurement.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer Part Number | MAX800LCPE |
| Manufacturer | Analog Devices Inc./Maxim Integrated |
| Category | Power Management (PMIC) |
| Type | Battery Backup Circuit |
| Number of Voltages Monitored | 1 |
| Voltage - Threshold | 4.65V |
| Output Configuration | Open Drain, Push-Pull |
| Reset Logic | Active High/Active Low |
| Reset Timeout | 140ms Minimum |
| Operating Temperature Range | 0°C ~ 70°C (TA) |
| Package / Case | 16-DIP (0.300", 7.62mm) |
| Mounting Type | Through Hole |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution of the MAX800LCPE is determined by strict equivalence across the following critical parameters:
- Single-channel voltage monitoring capability
- 4.65V threshold voltage specification
- Open Drain and Push-Pull output configuration
- Active High/Active Low reset logic
- 140ms minimum reset timeout
- 16-DIP through-hole package format
- Operating temperature range of 0°C to 70°C
The MAX800LCPE+ qualifies as a parametric equivalent based on identical electrical specifications and package configuration. Both devices share the same base product number (MAX800) and deliver equivalent functional performance within the defined operating parameters.
Parameter Comparison
| Parameter | MAX800LCPE | MAX800LCPE+ |
|---|---|---|
| Manufacturer | Analog Devices Inc./Maxim Integrated | Analog Devices Inc./Maxim Integrated |
| Category | Power Management (PMIC) | Power Management (PMIC) |
| Type | Battery Backup Circuit | Battery Backup Circuit |
| Number of Voltages Monitored | 1 | 1 |
| Voltage - Threshold | 4.65V | 4.65V |
| Output Configuration | Open Drain, Push-Pull | Open Drain, Push-Pull |
| Reset Logic | Active High/Active Low | Active High/Active Low |
| Reset Timeout | 140ms Minimum | 140ms Minimum |
| Operating Temperature Range | 0°C ~ 70°C (TA) | 0°C ~ 70°C (TA) |
| Package / Case | 16-DIP (0.300", 7.62mm) | 16-DIP (0.300", 7.62mm) |
| Mounting Type | Through Hole | Through Hole |
| Product Status | Obsolete | Obsolete |
| RoHS Status | RoHS non-compliant | ROHS3 Compliant |
Engineering Selection Recommendations
The MAX800LCPE+ serves as a direct parametric equivalent for the MAX800LCPE. Both devices are classified as obsolete products from the same manufacturer with identical electrical and mechanical specifications.
A key distinction exists in regulatory compliance: the MAX800LCPE+ achieves ROHS3 compliance, whereas the original MAX800LCPE is RoHS non-compliant. For applications subject to RoHS requirements or environmental regulations, the MAX800LCPE+ provides compliance alignment while maintaining full functional equivalence.
Both devices carry identical ECCN (EAR99) and HTSUS (8542.39.0001) classifications, with Moisture Sensitivity Level 1 (Unlimited). Component selection should be based on regulatory requirements and compliance mandates applicable to the end application.
Frequently Asked Questions (FAQ)
Q: Can the MAX800LCPE+ directly replace the MAX800LCPE in existing designs?
A: Yes. The MAX800LCPE+ is a parametric equivalent with identical electrical specifications, threshold voltage, output configuration, reset timing, and 16-DIP package format. Direct substitution is supported without circuit modification.
Q: What is the primary difference between these two parts?
A: The MAX800LCPE+ achieves ROHS3 compliance, while the MAX800LCPE is RoHS non-compliant. All electrical and mechanical parameters remain identical.
Q: Are both devices still in production?
A: No. Both the MAX800LCPE and MAX800LCPE+ are classified as obsolete products. Component availability should be verified through authorized distributors.
Q: Does the through-hole 16-DIP package remain the same for both parts?
A: Yes. Both devices use the 16-DIP (0.300", 7.62mm) through-hole package with identical pin configuration and mounting requirements.
Q: What operating temperature range applies to both devices?
A: Both the MAX800LCPE and MAX800LCPE+ operate across 0°C to 70°C (TA).
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts