MAX703CPA+ Equivalent & Substitute Parts

Part Overview

The MAX703CPA+ is a single-channel supervisor integrated circuit manufactured by Analog Devices Inc./Maxim Integrated, designed for battery backup circuit applications. This Power Management (PMIC) device operates as a push-pull, totem pole output supervisor with active-low reset functionality. The part is currently in active product status with 3100 units available in stock. Equivalent and substitute parts are identified based on matching electrical characteristics, mechanical compatibility, and functional performance within the specified operating parameters.

Substiute Parts

MAX703CPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 3173MAX703CPA+ Datasheet
MAX703CPA+
Current Part
MAX703CPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 3173MAX703CPA+ Datasheet
MAX703CPA+
Direct
MAX690ACPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 3689MAX690ACPA+ Datasheet
MAX690ACPA+
Parametric Equivalent
MAX694CPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 1972MAX694CPA+ Datasheet
MAX694CPA+
Parametric Equivalent
MAX802LCPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 1391MAX802LCPA+ Datasheet
MAX802LCPA+
Parametric Equivalent

Key Parameters

Parameter Specification
Manufacturer Analog Devices Inc./Maxim Integrated
Category Power Management (PMIC)
Type Battery Backup Circuit
Number of Voltages Monitored 1
Voltage Threshold 4.65V
Output Configuration Push-Pull, Totem Pole
Reset Logic Active Low
Reset Timeout 140ms Minimum
Operating Temperature Range 0°C ~ 70°C (TA)
Mounting Type Through Hole
Package / Case 8-DIP (0.300", 7.62mm)
Supplier Device Package 8-PDIP
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
REACH Status REACH Unaffected

Substitute Part Grouping Explanation

Substitute parts for the MAX703CPA+ are qualified based on strict parametric equivalence across the following critical criteria:

  • Voltage threshold matching at 4.65V
  • Single-channel voltage monitoring configuration
  • Push-pull, totem pole output topology
  • Active-low reset logic with 140ms minimum timeout
  • Operating temperature range of 0°C ~ 70°C
  • Through-hole mounting in 8-DIP package format
  • ROHS3 compliance and REACH unaffected status
  • Moisture sensitivity level MSL 1

All substitute parts listed maintain identical electrical performance characteristics and mechanical compatibility with the MAX703CPA+, enabling direct functional replacement within the specified application parameters.

Parameter Comparison

Part Number Manufacturer Product Status Voltage Threshold Output Type Reset Logic Reset Timeout Operating Temp Package Inventory (Pcs)
MAX703CPA+ Analog Devices Inc./Maxim Integrated Active 4.65V Push-Pull, Totem Pole Active Low 140ms Min 0°C ~ 70°C 8-DIP 3100
MAX690ACPA+ Analog Devices Inc./Maxim Integrated Active 4.65V Push-Pull, Totem Pole Active Low 140ms Min 0°C ~ 70°C 8-DIP 3600
MAX694CPA+ Analog Devices Inc./Maxim Integrated Active 4.65V Push-Pull, Totem Pole Active Low 140ms Min 0°C ~ 70°C 8-DIP 1924
MAX802LCPA+ Analog Devices Inc./Maxim Integrated Obsolete 4.65V Push-Pull, Totem Pole Active Low 140ms Min 0°C ~ 70°C 8-DIP 1325

Engineering Selection Recommendations

For new designs and active production environments, MAX690ACPA+ and MAX694CPA+ are the preferred substitute selections, as both maintain active product status with Analog Devices Inc./Maxim Integrated. Both parts carry identical electrical specifications and ROHS3 compliance certification, ensuring regulatory alignment with current manufacturing standards.

MAX802LCPA+ is available as a parametric equivalent but carries obsolete product status. Selection of this part should be limited to legacy system maintenance or applications where long-term supply continuity is not a requirement.

All substitute parts maintain ROHS3 compliance, REACH unaffected status, and MSL 1 moisture sensitivity rating, confirming compatibility with current environmental and regulatory requirements.

Frequently Asked Questions (FAQ)

Q: Can MAX690ACPA+ directly replace MAX703CPA+ in existing designs?

A: Yes. MAX690ACPA+ matches all critical electrical parameters including voltage threshold (4.65V), output configuration (push-pull, totem pole), reset logic (active low), and reset timeout (140ms minimum). Both parts use identical 8-DIP through-hole packaging and operate within the same temperature range (0°C ~ 70°C).

Q: What is the difference between MAX703CPA+ and MAX694CPA+?

A: Both parts are parametric equivalents with matching voltage threshold, output topology, reset characteristics, and package format. The primary distinction is the base product number (MAX703 versus MAX694). Electrical performance and mechanical compatibility are identical.

Q: Why is MAX802LCPA+ listed as obsolete?

A: MAX802LCPA+ carries obsolete product status from the manufacturer. While it maintains parametric equivalence with all specified electrical and mechanical parameters, new designs should prioritize active-status alternatives such as MAX690ACPA+ or MAX694CPA+ to ensure long-term supply availability.

Q: Are all substitute parts ROHS3 compliant?

A: Yes. All listed substitute parts (MAX690ACPA+, MAX694CPA+, and MAX802LCPA+) are ROHS3 compliant and REACH unaffected, confirming compatibility with current environmental regulations.

Q: Can these parts be used interchangeably in the same PCB layout?

A: Yes. All substitute parts use the 8-DIP (0.300", 7.62mm) through-hole package format with identical pin configurations, enabling direct PCB layout compatibility without modification.

Request Quote (Ships tomorrow)