Part Overview
The MAX188ACAP is a 12-bit data acquisition system (DAS) with 8 channels, 133k sampling rate, and serial data interface, manufactured by Analog Devices Inc./Maxim Integrated. This component is classified as obsolete, making identification of functionally equivalent alternatives essential for ongoing system support, redesigns, and procurement planning. The part operates across a 0°C to 70°C temperature range in a 20-SSOP surface mount package.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer Part Number | MAX188ACAP |
| Manufacturer | Analog Devices Inc./Maxim Integrated |
| Category | Data Acquisition |
| Number of Channels | 8 |
| Resolution | 12 bits |
| Sampling Rate | 133k samples per second |
| Data Interface | Serial |
| Voltage Supply | Dual ± |
| Operating Temperature | 0°C to 70°C |
| Package Type | 20-SSOP (0.209", 5.30mm Width) |
| Mounting Type | Surface Mount |
| Product Status | Obsolete |
| RoHS Status | RoHS non-compliant |
| Moisture Sensitivity Level | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution of the MAX188ACAP is determined by strict equivalence across the following critical parameters:
- Channel Count: 8 channels (fixed requirement)
- Resolution: 12 bits (fixed requirement)
- Sampling Rate: 133k samples per second (fixed requirement)
- Package: 20-SSOP form factor with identical pin pitch and dimensions
- Data Interface: Serial protocol compatibility (MICROWIRE™, QSPI™, SPI™ acceptable as serial variants)
- Voltage Supply Architecture: Dual ± supply configuration
- Operating Temperature Range: 0°C to 70°C minimum coverage
- Mounting Technology: Surface mount only
The MAX188ACAP+ qualifies as a direct substitute based on matching all electrical and mechanical parameters while offering improved compliance status.
Parameter Comparison
| Parameter | MAX188ACAP (Main Part) | MAX188ACAP+ (Substitute) |
|---|---|---|
| Manufacturer | Analog Devices Inc./Maxim Integrated | Analog Devices Inc./Maxim Integrated |
| Number of Channels | 8 | 8 |
| Resolution (Bits) | 12 | 12 |
| Sampling Rate | 133k | 133k |
| Data Interface | Serial | MICROWIRE™, QSPI™, Serial, SPI™ |
| Voltage Supply Source | Dual ± | Dual ± (±5V) |
| Operating Temperature | 0°C to 70°C | 0°C to 70°C |
| Package / Case | 20-SSOP (0.209", 5.30mm Width) | 20-SSOP (0.209", 5.30mm Width) |
| Mounting Type | Surface Mount | Surface Mount |
| Product Status | Obsolete | Obsolete |
| RoHS Status | RoHS non-compliant | ROHS3 Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
The MAX188ACAP+ serves as the direct equivalent for MAX188ACAP applications. Both parts maintain identical electrical specifications across channel count, resolution, sampling rate, and operating temperature range. The primary distinction is regulatory compliance: MAX188ACAP+ achieves ROHS3 compliance, whereas the original MAX188ACAP is RoHS non-compliant. For new designs or systems requiring RoHS compliance, MAX188ACAP+ is the appropriate selection. For legacy system maintenance where RoHS compliance is not mandated, either part satisfies functional requirements. Both components are classified as obsolete; long-term availability should be confirmed with authorized distributors prior to procurement decisions.
Frequently Asked Questions (FAQ)
Q: Can MAX188ACAP+ replace MAX188ACAP in existing designs? A: Yes. Both parts are electrically and mechanically identical across all functional parameters. The 20-SSOP package pinout and signal timing are equivalent, enabling direct substitution on PCBs designed for MAX188ACAP.
Q: What is the difference between the serial interfaces listed for MAX188ACAP+? A: MAX188ACAP+ supports MICROWIRE™, QSPI™, Serial, and SPI™ protocols. These are serial communication variants compatible with the same 20-SSOP pinout. The original MAX188ACAP specification lists "Serial" generically; MAX188ACAP+ provides explicit protocol options.
Q: Are there packaging differences between these parts? A: No. Both MAX188ACAP and MAX188ACAP+ use identical 20-SSOP packaging with 0.209" width and 5.30mm dimensions. Supplier device packages are equivalent.
Q: Why is RoHS compliance different between the two parts? A: MAX188ACAP predates RoHS3 requirements and is non-compliant. MAX188ACAP+ was manufactured to meet ROHS3 standards. For applications subject to RoHS regulations, MAX188ACAP+ is the required selection.
Q: Are both parts still in production? A: Both MAX188ACAP and MAX188ACAP+ are classified as obsolete. Availability is limited to existing inventory from authorized distributors. Verify stock status and lead times before finalizing procurement.
Q: What is the moisture sensitivity level, and does it affect handling? A: Both parts carry MSL 1 (Unlimited), indicating no moisture sensitivity restrictions. Standard handling procedures for surface mount components apply.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts