MAX186AEWP Equivalent & Substitute Parts

Part Overview

The MAX186AEWP is a 12-bit Data Acquisition System (DAS) integrated circuit manufactured by Analog Devices Inc./Maxim Integrated. This device features 8 channels, a 133 kHz sampling rate, and serial data interface capability in a 20-SOIC surface mount package. The MAX186AEWP is classified as obsolete, making identification of compatible substitute components essential for ongoing system support, design updates, and procurement continuity.

Substiute Parts

MAX186AEWP
Analog Devices Inc./Maxim IntegratedIn Stock: 2762MAX186AEWP Datasheet
MAX186AEWP
Current Part
MAX186AEWP+
Analog Devices Inc./Maxim IntegratedIn Stock: 2318MAX186AEWP+ Datasheet
MAX186AEWP+
Direct

Key Parameters

Parameter Specification
Manufacturer Part Number MAX186AEWP
Manufacturer Analog Devices Inc./Maxim Integrated
Product Category Data Acquisition
Number of Channels 8
Resolution 12 bits
Sampling Rate 133 kHz
Data Interface Serial
Voltage Supply Dual ±
Operating Temperature Range -40°C to 85°C
Package Type 20-SOIC (0.295", 7.50mm Width)
Mounting Type Surface Mount
Product Status Obsolete
RoHS Status RoHS non-compliant
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the MAX186AEWP is determined by strict equivalence across the following critical parameters:

  • Channel Count: 8 channels (fixed requirement)
  • Resolution: 12 bits (fixed requirement)
  • Sampling Rate: 133 kHz (fixed requirement)
  • Package Type: 20-SOIC form factor (fixed requirement)
  • Mounting Type: Surface mount (fixed requirement)
  • Operating Temperature Range: -40°C to 85°C (fixed requirement)
  • Voltage Supply Configuration: Dual ± supply (fixed requirement)

The MAX186AEWP+ qualifies as a direct substitute based on matching all critical electrical and mechanical parameters. The primary distinction is product status: the MAX186AEWP+ is active and RoHS3 compliant, whereas the original part is obsolete and RoHS non-compliant.

Parameter Comparison

Parameter MAX186AEWP (Main Part) MAX186AEWP+ (Substitute)
Manufacturer Analog Devices Inc./Maxim Integrated Analog Devices Inc./Maxim Integrated
Number of Channels 8 8
Resolution (Bits) 12 12
Sampling Rate (Per Second) 133k 133k
Data Interface Serial MICROWIRE™, QSPI™, Serial, SPI™
Voltage Supply Source Dual ± Dual ± (±5V)
Operating Temperature -40°C to 85°C -40°C to 85°C
Package / Case 20-SOIC (0.295", 7.50mm Width) 20-SOIC (0.295", 7.50mm Width)
Mounting Type Surface Mount Surface Mount
Product Status Obsolete Active
RoHS Status RoHS non-compliant RoHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

The MAX186AEWP+ is the direct functional equivalent of the MAX186AEWP. Selection of the MAX186AEWP+ is supported by the following factors:

  • Product Status: The MAX186AEWP+ maintains active product status, ensuring continued manufacturer support and availability.
  • Regulatory Compliance: The MAX186AEWP+ is RoHS3 compliant, meeting current environmental and regulatory requirements. The original MAX186AEWP is RoHS non-compliant.
  • Electrical Equivalence: All critical electrical parameters—channel count, resolution, sampling rate, supply voltage configuration, and operating temperature range—are identical.
  • Mechanical Compatibility: Both parts use the identical 20-SOIC package, ensuring direct PCB footprint compatibility without layout modifications.
  • Interface Compatibility: The MAX186AEWP+ supports multiple serial interface protocols (MICROWIRE™, QSPI™, Serial, SPI™), providing backward compatibility with existing serial interface implementations while offering expanded protocol flexibility.

Frequently Asked Questions (FAQ)

Q: Can the MAX186AEWP+ be used as a direct replacement for the MAX186AEWP in existing designs?

A: Yes. The MAX186AEWP+ is electrically and mechanically equivalent. Both parts feature 8 channels, 12-bit resolution, 133 kHz sampling rate, and identical 20-SOIC packaging. No PCB modifications or design changes are required.

Q: What is the primary difference between the MAX186AEWP and MAX186AEWP+?

A: The MAX186AEWP+ is an active product with RoHS3 compliance, while the MAX186AEWP is obsolete and RoHS non-compliant. The MAX186AEWP+ also supports expanded serial interface protocols (MICROWIRE™, QSPI™, SPI™) in addition to standard serial operation.

Q: Are there any package or pinout differences between these parts?

A: No. Both parts use the 20-SOIC package with identical pinout and mechanical dimensions (0.295", 7.50mm width). Direct PCB compatibility is maintained.

Q: What supply voltage is required for the MAX186AEWP+?

A: The MAX186AEWP+ operates on a dual ± supply configuration at ±5V, matching the dual ± supply requirement of the original MAX186AEWP.

Q: Is the MAX186AEWP+ suitable for applications requiring RoHS compliance?

A: Yes. The MAX186AEWP+ is RoHS3 compliant, making it suitable for applications and markets with RoHS regulatory requirements.

Q: What is the operating temperature range for both parts?

A: Both the MAX186AEWP and MAX186AEWP+ operate across the temperature range of -40°C to 85°C, supporting industrial and extended commercial applications.

Request Quote (Ships tomorrow)