Part Overview

The MAX1240ACSA+ is a 12-bit Analog-to-Digital Converter (ADC) manufactured by Analog Devices Inc./Maxim Integrated, designed for single-ended input data acquisition applications. This component features a Successive Approximation Register (SAR) architecture with SPI digital interface and operates across a 2.7V to 3.6V supply voltage range. The MAX1240ACSA+ is classified as obsolete, making identification of active equivalent parts essential for new designs and production continuity.

Substiute Parts

MAX1240ACSA+
Analog Devices Inc./Maxim IntegratedIn Stock: 1072MAX1240ACSA+ Datasheet
MAX1240ACSA+
Current Part
MAX1240ACSA+
Analog Devices Inc./Maxim IntegratedIn Stock: 1072MAX1240ACSA+ Datasheet
MAX1240ACSA+
Direct
MAX1240BCSA+
Analog Devices Inc./Maxim IntegratedIn Stock: 2922MAX1240BCSA+ Datasheet
MAX1240BCSA+
Parametric Equivalent
MAX1240CCSA+
Analog Devices Inc./Maxim IntegratedIn Stock: 1010MAX1240CCSA+ Datasheet
MAX1240CCSA+
Parametric Equivalent

Key Parameters

Parameter Value
Resolution 12 Bit
Sampling Rate 73 kSPS
Number of Inputs 1
Input Type Single Ended
Data Interface SPI
Architecture SAR
Reference Type External, Internal
Analog Supply Voltage 2.7V ~ 3.6V
Digital Supply Voltage 2.7V ~ 3.6V
Operating Temperature 0°C ~ 70°C
Package 8-SOIC (0.154", 3.90mm Width)
Mounting Type Surface Mount
RoHS Status ROHS3 Compliant
MSL Rating 1 (Unlimited)

Substitute Part Grouping Explanation

Substitute parts for the MAX1240ACSA+ are determined by matching the following critical parameters:

  • Resolution & Sampling Rate: 12-bit resolution at 73 kSPS
  • Input Configuration: Single-ended input with 1 ADC channel
  • Digital Interface: SPI protocol
  • Architecture: SAR-based conversion
  • Reference Options: External and internal reference support
  • Supply Voltage Range: 2.7V to 3.6V for both analog and digital supplies
  • Package & Pinout: 8-SOIC form factor with identical pin configuration
  • Environmental Compliance: ROHS3 compliance and MSL Level 1 rating

The MAX1240BCSA+ and MAX1240CCSA+ meet all these parameters identically to the MAX1240ACSA+, with the primary distinction being product status and temperature grade designation (indicated by the letter suffix).

Parameter Comparison

Parameter MAX1240ACSA+ MAX1240BCSA+ MAX1240CCSA+
Manufacturer Analog Devices Inc./Maxim Integrated Analog Devices Inc./Maxim Integrated Analog Devices Inc./Maxim Integrated
Product Status Obsolete Active Active
Resolution 12 Bit 12 Bit 12 Bit
Sampling Rate 73 kSPS 73 kSPS 73 kSPS
Number of Inputs 1 1 1
Input Type Single Ended Single Ended Single Ended
Data Interface SPI SPI SPI
Architecture SAR SAR SAR
Reference Type External, Internal External, Internal External, Internal
Analog Supply Voltage 2.7V ~ 3.6V 2.7V ~ 3.6V 2.7V ~ 3.6V
Digital Supply Voltage 2.7V ~ 3.6V 2.7V ~ 3.6V 2.7V ~ 3.6V
Operating Temperature 0°C ~ 70°C 0°C ~ 70°C 0°C ~ 70°C
Package / Case 8-SOIC (0.154", 3.90mm Width) 8-SOIC (0.154", 3.90mm Width) 8-SOIC (0.154", 3.90mm Width)
Mounting Type Surface Mount Surface Mount Surface Mount
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
MSL Rating 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)
Inventory Status 970 Pcs New Original In Stock 2900 Pcs New Original In Stock 918 Pcs New Original In Stock

Engineering Selection Recommendations

For applications currently using the MAX1240ACSA+, the MAX1240BCSA+ and MAX1240CCSA+ are direct parametric equivalents. Both substitute parts maintain identical electrical specifications, package configuration, and compliance certifications.

The primary selection criterion is product status: MAX1240BCSA+ and MAX1240CCSA+ are active products with ongoing manufacturer support, whereas MAX1240ACSA+ is obsolete. For new designs or production continuity, selection between MAX1240BCSA+ and MAX1240CCSA+ should be based on availability and supply chain requirements, as both parts are functionally interchangeable within the specified operating parameters.

All three variants maintain ROHS3 compliance and MSL Level 1 rating, ensuring compatibility with standard manufacturing and storage protocols.

Frequently Asked Questions (FAQ)

Q: Are MAX1240BCSA+ and MAX1240CCSA+ pin-for-pin compatible with MAX1240ACSA+?

A: Yes. All three parts use the 8-SOIC package with identical pinout and electrical interface specifications. Direct PCB substitution is supported without layout modifications.

Q: What is the functional difference between MAX1240ACSA+, MAX1240BCSA+, and MAX1240CCSA+?

A: There is no functional difference. All three parts share identical electrical specifications, including 12-bit resolution, 73 kSPS sampling rate, SPI interface, and supply voltage range. The letter suffix indicates temperature grade and product lifecycle status only.

Q: Can I substitute an obsolete MAX1240ACSA+ with an active MAX1240BCSA+ or MAX1240CCSA+ in existing designs?

A: Yes. The parametric equivalence is complete across all critical specifications. No design changes are required for direct substitution.

Q: Are there any package or compliance differences between these parts?

A: No. All three variants are supplied in 8-SOIC packaging, maintain ROHS3 compliance, and carry MSL Level 1 rating. Moisture sensitivity and environmental handling requirements are identical.

Q: Which substitute part should I select for new production?

A: Either MAX1240BCSA+ or MAX1240CCSA+ is appropriate for new designs. Both are active products. Selection should be based on availability, lead time, and supply chain considerations, as electrical and mechanical specifications are identical.

Request Quote (Ships tomorrow)