LV 25-P Voltage Closed Loop Sensor Equivalent & Substitute Parts

Part Overview

The LV 25-P is a voltage closed loop sensor manufactured by LEM USA Inc., designed to provide voltage output in closed loop measurement applications. This component is classified as not for new designs, indicating it has been superseded in the manufacturer's product roadmap. For applications currently utilizing the LV 25-P, identifying compatible substitute parts ensures design continuity and supply chain flexibility while maintaining functional equivalence.

Substiute Parts

LV 25-P
LEM USA Inc.In Stock: 10183LV 25-P Datasheet
LV 25-P
Current Part
LV 20-P
LEM USA Inc.In Stock: 967LV 20-P Datasheet
LV 20-P
Direct

Key Parameters

Parameter Value
Manufacturer LEM USA Inc.
Series LV
Sensor Type Voltage, Closed Loop
Output Type Voltage
Operating Temperature Range 0°C to 70°C
RoHS Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
REACH Status REACH Unaffected
ECCN Classification EAR99
HTSUS Code 9030.33.3400
Product Status Not For New Designs

Substitute Part Grouping Explanation

Substitution eligibility for the LV 25-P is determined by strict alignment across the following critical parameters:

Mandatory Matching Parameters:

  • Manufacturer: LEM USA Inc.
  • Series: LV
  • Sensor Type: Voltage, Closed Loop
  • Output Type: Voltage
  • Operating Temperature Range: 0°C to 70°C
  • RoHS Compliance: RoHS Compliant
  • Moisture Sensitivity Level: 1 (Unlimited)
  • REACH Status: REACH Unaffected
  • ECCN Classification: EAR99
  • HTSUS Code: 9030.33.3400

The LV 20-P meets all mandatory matching parameters and is therefore classified as a direct substitute for the LV 25-P. Both components share identical functional specifications, regulatory compliance status, and environmental operating conditions.

Parameter Comparison

Parameter LV 25-P (Main Part) LV 20-P (Substitute) Match Status
Manufacturer LEM USA Inc. LEM USA Inc. Match
Series LV LV Match
Sensor Type Voltage, Closed Loop Voltage, Closed Loop Match
Output Type Voltage Voltage Match
Operating Temperature Range 0°C to 70°C 0°C to 70°C Match
RoHS Status RoHS Compliant RoHS Compliant Match
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) Match
REACH Status REACH Unaffected REACH Unaffected Match
ECCN Classification EAR99 EAR99 Match
HTSUS Code 9030.33.3400 9030.33.3400 Match
Product Status Not For New Designs Not For New Designs Match
Packaging Tube Bulk Different

Engineering Selection Recommendations

The LV 20-P is a direct functional equivalent to the LV 25-P based on identical electrical specifications, sensor type, output characteristics, and operating temperature range. Both components carry equivalent regulatory compliance certifications including RoHS compliance, REACH unaffected status, and EAR99 export classification.

The primary distinction between these parts is packaging format: the LV 25-P is supplied in tube packaging, while the LV 20-P is supplied in bulk packaging. This packaging difference does not affect functional performance or electrical characteristics and should be evaluated based on assembly process requirements and inventory management practices.

Both components share "Not For New Designs" product status, indicating manufacturer discontinuation. For new design initiatives, consultation with LEM USA Inc. regarding current generation voltage closed loop sensor offerings is recommended to identify products with active production status.

Frequently Asked Questions (FAQ)

Q: Can the LV 20-P directly replace the LV 25-P in existing applications?

A: Yes. The LV 20-P is a direct substitute for the LV 25-P. All electrical parameters, sensor type, output type, operating temperature range, and regulatory compliance specifications are identical between the two parts.

Q: What is the difference between the LV 25-P and LV 20-P?

A: The LV 25-P and LV 20-P are functionally equivalent voltage closed loop sensors with identical electrical and environmental specifications. The only difference is packaging: LV 25-P is supplied in tube packaging, while LV 20-P is supplied in bulk packaging.

Q: Are there any compliance or regulatory differences between these parts?

A: No. Both the LV 25-P and LV 20-P carry identical compliance certifications: RoHS compliant, REACH unaffected, EAR99 export classification, and the same HTSUS code (9030.33.3400).

Q: Does packaging format affect electrical performance?

A: No. Packaging format (tube versus bulk) does not affect electrical performance, functional characteristics, or operating specifications. The choice between packaging formats should be based on assembly process requirements and inventory management needs.

Q: Why are both parts marked "Not For New Designs"?

A: Both the LV 25-P and LV 20-P carry "Not For New Designs" product status, indicating these components have been superseded in the manufacturer's product line. For new design initiatives, contact LEM USA Inc. to identify current generation voltage closed loop sensor alternatives.

Q: What is the moisture sensitivity level (MSL) for these parts?

A: Both parts have MSL 1 (Unlimited), indicating no moisture sensitivity restrictions during storage or handling.

Request Quote (Ships tomorrow)