LD2-560-R Equivalent & Substitute Parts

Part Overview

The LD2-560-R is a 56 µH unshielded drum core wirewound inductor manufactured by Eaton - Electronics Division. This surface mount component is rated for 1.96 A continuous current with a maximum DC resistance of 240 mOhm and operates across the temperature range of -40°C to 125°C. The part is RoHS Compliant and carries an Active product status, indicating current availability and ongoing manufacturer support. Substitute parts are identified when equivalent electrical and mechanical specifications are required due to inventory constraints, design optimization, or supply chain considerations.

Substiute Parts

LD2-560-R
Eaton - Electronics DivisionIn Stock: 870LD2-560-R Datasheet
LD2-560-R
Current Part
SDR0805-560KL
Bourns Inc.In Stock: 4289SDR0805-560KL Datasheet
SDR0805-560KL
Similar

Key Parameters

Parameter Value
Inductance 56 µH
Current Rating 1.96 A
DC Resistance (DCR) 240 mOhm Max
Core Material Ferrite
Shielding Unshielded
Mounting Type Surface Mount
Operating Temperature -40°C to 125°C
Saturation Current (Isat) 1.5 A
RoHS Status RoHS Compliant

Substitute Part Grouping Explanation

Substitution of the LD2-560-R is based on the following critical electrical and mechanical parameters:

Primary Substitution Criteria:

  • Inductance value: 56 µH (exact match required)
  • Core type: Ferrite drum core, wirewound, unshielded
  • DC resistance: 240 mOhm maximum
  • Saturation current: 1.5 A minimum
  • Operating temperature range: -40°C to 125°C minimum
  • Mounting: Surface mount configuration
  • Compliance: RoHS status

The SDR0805-560KL from Bourns Inc. meets these core electrical specifications. However, the substitute part exhibits a lower continuous current rating of 940 mA compared to the main part's 1.96 A rating. This difference requires evaluation based on actual circuit requirements.

Parameter Comparison

Parameter LD2-560-R (Eaton) SDR0805-560KL (Bourns)
Inductance 56 µH 56 µH
Inductance Tolerance ±20% ±10%
Current Rating (Continuous) 1.96 A 940 mA
Saturation Current (Isat) 1.5 A 1.5 A
DC Resistance (DCR) 240 mOhm Max 240 mOhm Max
Core Material Ferrite Ferrite
Shielding Unshielded Unshielded
Operating Temperature -40°C to 125°C -40°C to 125°C
Mounting Type Surface Mount Surface Mount
RoHS Status RoHS Compliant ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited)
Package Type Nonstandard Nonstandard
Size / Dimension 0.307" L x 0.276" W (7.80mm x 7.00mm) 0.307" L x 0.307" W (7.80mm x 7.80mm)
Height - Seated (Max) 0.197" (5.00mm) 0.209" (5.30mm)

Engineering Selection Recommendations

LD2-560-R Selection Criteria: The LD2-560-R is the primary choice when continuous current requirements reach or exceed 1.5 A. This part carries Active product status with RoHS Compliant certification. The ±20% inductance tolerance is suitable for applications where tighter tolerance is not critical.

SDR0805-560KL Selection Criteria: The SDR0805-560KL from Bourns is suitable for applications where continuous current does not exceed 940 mA. This substitute offers improved inductance tolerance (±10% versus ±20%) and carries ROHS3 Compliant certification, indicating compliance with the latest RoHS directives. The part maintains identical DC resistance and saturation current specifications.

Compliance Considerations: Both parts are RoHS compliant and operate within the same temperature range. The SDR0805-560KL provides enhanced compliance status through ROHS3 certification and includes REACH Unaffected designation.

Frequently Asked Questions (FAQ)

Q: Can the SDR0805-560KL replace the LD2-560-R in all applications?

A: The SDR0805-560KL is electrically equivalent for inductance, DC resistance, and saturation current. However, the continuous current rating of 940 mA is lower than the LD2-560-R's 1.96 A rating. Substitution is valid only when circuit current requirements do not exceed 940 mA continuous operation.

Q: What are the physical differences between these parts?

A: The LD2-560-R measures 0.307" L x 0.276" W x 0.197" H (7.80mm x 7.00mm x 5.00mm). The SDR0805-560KL measures 0.307" L x 0.307" W x 0.209" H (7.80mm x 7.80mm x 5.30mm). The width and height differ slightly, requiring PCB layout verification before substitution.

Q: How do the inductance tolerances compare?

A: The LD2-560-R carries ±20% tolerance, while the SDR0805-560KL offers tighter ±10% tolerance. Applications requiring inductance accuracy benefit from the SDR0805-560KL specification.

Q: Are both parts suitable for high-temperature applications?

A: Both parts operate across -40°C to 125°C, meeting identical temperature requirements. No thermal performance differentiation exists between the two parts.

Q: What is the significance of the different RoHS certifications?

A: The LD2-560-R carries RoHS Compliant status, while the SDR0805-560KL carries ROHS3 Compliant status. ROHS3 represents the current RoHS directive version. Both certifications indicate lead-free and hazardous substance compliance; ROHS3 reflects the most recent regulatory framework.

Q: Can these parts be used interchangeably on the same PCB?

A: Physical dimensions differ slightly. PCB footprint and component placement must accommodate the SDR0805-560KL's larger width (7.80mm versus 7.00mm) and height (5.30mm versus 5.00mm) before substitution.

Request Quote (Ships tomorrow)