LCDX2/0-12DH-X Equivalent & Substitute Parts

Part Overview

The LCDX2/0-12DH-X is a rectangular tongue terminal connector manufactured by Panduit Corp, designed for 2/0 AWG wire applications with a 1/2 inch stud connection. This non-insulated copper terminal features electro-tin contact finish and is configured for crimp barrel termination with two stud holes and a 45° angle mounting orientation.

The LCDX2/0-12DH-X carries an obsolete product status. Identifying equivalent and substitute parts is necessary to maintain design continuity, ensure supply chain availability, and support ongoing maintenance and repair operations for systems utilizing this terminal connector.

Substiute Parts

LCDX2/0-12DH-X
Panduit CorpIn Stock: 831LCDX2/0-12DH-X Datasheet
LCDX2/0-12DH-X
Current Part
LCCX2/0-12-X
Panduit CorpIn Stock: 1058LCCX2/0-12-X Datasheet
LCCX2/0-12-X
Similar

Key Parameters

Parameter Value
Wire Gauge 2/0 AWG
Stud/Tab Size 1/2 Stud
Terminal Type Rectangular Tongue
Terminal Style Two Stud Holes
Termination Method Crimp, Barrel
Contact Material Copper
Contact Finish Electro-Tin
Insulation Non-Insulated
Barrel ID 0.510" (12.95mm)
Barrel OD 0.640" (16.26mm)
Ring ID 0.530" (13.46mm)
Tab Thickness 0.130" (3.30mm)
Width - Outer Edges 0.960" (24.38mm)
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the LCDX2/0-12DH-X is determined by strict equivalence across the following critical parameters:

Electrical Parameters: Wire gauge (2/0 AWG), barrel inner diameter (0.510"), barrel outer diameter (0.640"), ring inner diameter (0.530"), contact material (copper), and contact finish (electro-tin) must remain identical to ensure proper electrical conductivity and connection integrity.

Mechanical Parameters: Terminal type (rectangular tongue), terminal style (two stud holes), stud size (1/2 inch), tab thickness (0.130"), and outer width (0.960") must match to ensure mechanical compatibility with mating components and mounting surfaces.

Material & Compliance Parameters: Insulation type (non-insulated), termination method (crimp barrel), and RoHS3 compliance status must be maintained.

The LCCX2/0-12-X qualifies as a direct substitute based on complete alignment across all critical electrical, mechanical, and compliance parameters. The primary distinction is product status and mounting configuration.

Parameter Comparison

Parameter LCDX2/0-12DH-X (Main Part) LCCX2/0-12-X (Substitute)
Manufacturer Panduit Corp Panduit Corp
Series Pan-Lug™ Pan-Lug™
Product Status Obsolete Active
Wire Gauge 2/0 AWG 2/0 AWG
Terminal Type Rectangular Tongue Rectangular Tongue
Stud/Tab Size 1/2 Stud 1/2 Stud
Terminal Style Two Stud Holes Two Stud Holes
Tab Thickness 0.130" (3.30mm) 0.130" (3.30mm)
Width - Outer Edges 0.960" (24.38mm) 0.960" (24.38mm)
Termination Crimp, Barrel Crimp, Barrel
Insulation Non-Insulated Non-Insulated
Color Black Black
Contact Finish Electro-Tin Electro-Tin
Contact Material Copper Copper
Barrel ID 0.510" (12.95mm) 0.510" (12.95mm)
Barrel OD 0.640" (16.26mm) 0.640" (16.26mm)
Ring ID 0.530" (13.46mm) 0.530" (13.46mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
Mounting Type Free Hanging (In-Line), 45° Angle Free Hanging (In-Line)
Packaging Not Specified Bulk
Inventory Status 785 Pcs New Original In Stock 1003 Pcs New Original In Stock

Engineering Selection Recommendations

LCCX2/0-12-X Selection Basis:

The LCCX2/0-12-X is the direct substitute for the obsolete LCDX2/0-12DH-X. Both parts maintain identical electrical and mechanical specifications across all critical parameters: wire gauge, stud size, terminal geometry, barrel dimensions, contact material, and contact finish.

The LCCX2/0-12-X carries active product status, ensuring ongoing availability and supply chain support. Both parts maintain ROHS3 compliance and REACH unaffected status, satisfying regulatory requirements for new installations and replacement applications.

The primary operational difference is mounting configuration: the LCDX2/0-12DH-X specifies 45° angle mounting, while the LCCX2/0-12-X specifies standard in-line mounting. This distinction affects physical orientation during installation but does not alter electrical performance or mechanical compatibility with mating components.

The LCCX2/0-12-X is available in bulk packaging with higher inventory levels (1003 pieces), supporting both immediate procurement needs and long-term supply continuity.

Frequently Asked Questions (FAQ)

Q: Can the LCCX2/0-12-X directly replace the LCDX2/0-12DH-X in existing applications?

A: The LCCX2/0-12-X is electrically and mechanically equivalent to the LCDX2/0-12DH-X across all critical parameters. The mounting orientation difference (45° angle versus in-line) must be evaluated within the specific application context to confirm physical fit and spatial constraints.

Q: What are the key electrical parameters that must match for substitution?

A: Wire gauge (2/0 AWG), barrel inner diameter (0.510"), barrel outer diameter (0.640"), ring inner diameter (0.530"), contact material (copper), and contact finish (electro-tin) must remain identical. These parameters directly affect electrical conductivity, current capacity, and connection reliability.

Q: Are there compliance differences between the two parts?

A: Both parts maintain identical compliance status: ROHS3 compliant and REACH unaffected. No regulatory barriers exist for substitution.

Q: What is the significance of the mounting type difference?

A: The LCDX2/0-12DH-X includes 45° angle mounting specification, while the LCCX2/0-12-X specifies standard in-line mounting. This affects the physical orientation of the terminal during installation. Verify that the application environment and connection geometry accommodate the in-line mounting configuration.

Q: Why is the LCDX2/0-12DH-X marked as obsolete?

A: Obsolete status indicates the part is no longer in active production. The LCCX2/0-12-X represents the current active equivalent, ensuring access to new inventory and ongoing manufacturer support.

Q: Does packaging type affect electrical or mechanical performance?

A: Packaging type (bulk versus other configurations) does not affect electrical or mechanical performance. It impacts procurement logistics, inventory management, and handling procedures only.

Q: Are both parts suitable for new designs?

A: The LCCX2/0-12-X, carrying active product status, is the appropriate selection for new designs. The LCDX2/0-12DH-X, marked obsolete, should be used only for replacement or repair of existing systems where the 45° angle mounting is specifically required.

Request Quote (Ships tomorrow)