LCCF6-14B-L Equivalent & Substitute Parts

Part Overview

The LCCF6-14B-L is a rectangular tongue terminal connector manufactured by Panduit Corp, designed for 6 AWG wire termination with a 1/4 inch stud connection. This component is classified as obsolete, necessitating identification of active equivalent parts to maintain supply chain continuity and ensure availability for new designs and repairs. The terminal features non-insulated copper construction with electro-tin contact finish, suitable for free-hanging in-line mounting applications requiring crimp barrel termination.

Substiute Parts

LCCF6-14B-L
Panduit CorpIn Stock: 950LCCF6-14B-L Datasheet
LCCF6-14B-L
Current Part
LCCF6-14A-L
Panduit CorpIn Stock: 1029LCCF6-14A-L Datasheet
LCCF6-14A-L
Similar

Key Parameters

Parameter Value
Wire Gauge 6 AWG
Stud/Tab Size 1/4 Stud
Terminal Type Rectangular Tongue
Terminal Style Two Stud Holes
Termination Method Crimp, Barrel
Contact Material Copper
Contact Finish Electro-Tin
Insulation Non-Insulated
Mounting Type Free Hanging (In-Line)
Barrel ID 0.220" (5.59mm)
Barrel OD 0.370" (9.40mm)
Ring ID 0.270" (6.86mm)
Tab Thickness 0.080" (2.03mm)
Width - Outer Edges 0.480" (12.19mm)

Substitute Part Grouping Explanation

The LCCF6-14B-L shares functional equivalence with the LCCF6-14A-L based on the following critical parameters that determine substitution compatibility:

Electrical Parameters:

  • Wire gauge: 6 AWG (identical)
  • Stud/tab size: 1/4 inch (identical)
  • Barrel inner diameter: 0.220" (5.59mm) (identical)
  • Barrel outer diameter: 0.370" (9.40mm) (identical)
  • Ring inner diameter: 0.270" (6.86mm) (identical)

Mechanical Parameters:

  • Terminal type: Rectangular tongue (identical)
  • Terminal style: Two stud holes (identical)
  • Tab thickness: 0.080" (2.03mm) (identical)
  • Width - outer edges: 0.480" (12.19mm) (identical)
  • Mounting type: Free hanging in-line (identical)
  • Termination method: Crimp barrel (identical)

Material & Finish Parameters:

  • Contact material: Copper (identical)
  • Contact finish: Electro-tin (identical)
  • Insulation: Non-insulated (identical)

The primary distinction between these parts is overall length and product status. The LCCF6-14A-L is an active product, whereas the LCCF6-14B-L is obsolete.

Parameter Comparison

Parameter LCCF6-14B-L (Main Part) LCCF6-14A-L (Substitute)
Manufacturer Panduit Corp Panduit Corp
Series Pan-Lug™ Pan-Lug™
Wire Gauge 6 AWG 6 AWG
Stud/Tab Size 1/4 Stud 1/4 Stud
Terminal Type Rectangular Tongue Rectangular Tongue
Terminal Style Two Stud Holes Two Stud Holes
Tab Thickness 0.080" (2.03mm) 0.080" (2.03mm)
Length - Overall 2.830" (71.88mm) 2.710" (68.83mm)
Width - Outer Edges 0.480" (12.19mm) 0.480" (12.19mm)
Mounting Type Free Hanging (In-Line) Free Hanging (In-Line)
Termination Crimp, Barrel Crimp, Barrel
Insulation Non-Insulated Non-Insulated
Color Blue Blue
Contact Finish Electro-Tin Electro-Tin
Contact Material Copper Copper
Diameter - Barrel ID 0.220" (5.59mm) 0.220" (5.59mm)
Diameter - Barrel OD 0.370" (9.40mm) 0.370" (9.40mm)
Diameter - Ring ID 0.270" (6.86mm) 0.270" (6.86mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
Product Status Obsolete Active

Engineering Selection Recommendations

The LCCF6-14A-L serves as the direct functional equivalent to the LCCF6-14B-L for applications requiring 6 AWG rectangular tongue terminals with 1/4 inch stud connections. Both parts maintain identical electrical and mechanical specifications across all critical parameters including wire gauge, stud size, barrel dimensions, tab thickness, and contact material composition.

The LCCF6-14A-L is the preferred selection for new designs and ongoing production due to its active product status. Both parts satisfy ROHS3 compliance and REACH unaffected regulatory requirements, ensuring compatibility with current environmental and safety standards.

The 0.120 inch (3.05mm) difference in overall length between the LCCF6-14B-L and LCCF6-14A-L does not affect functional performance in applications where the terminal engages with 1/4 inch studs, as this dimension variation falls within acceptable tolerance ranges for free-hanging in-line mounting configurations.

Frequently Asked Questions (FAQ)

Q: Can the LCCF6-14A-L directly replace the LCCF6-14B-L in existing assemblies?

A: Yes. The LCCF6-14A-L maintains identical electrical and mechanical specifications for wire gauge, stud connection size, barrel dimensions, tab thickness, contact material, and termination method. The minor difference in overall length does not affect functional compatibility in applications using 1/4 inch stud connections.

Q: What is the significance of the product status difference between these parts?

A: The LCCF6-14B-L is classified as obsolete, indicating discontinued manufacturing. The LCCF6-14A-L is an active product with current manufacturing and supply availability. For new designs and ongoing production requirements, the LCCF6-14A-L should be specified.

Q: Are both parts compliant with current regulatory standards?

A: Yes. Both the LCCF6-14B-L and LCCF6-14A-L are ROHS3 compliant and REACH unaffected, meeting current environmental and safety requirements.

Q: What is the difference in overall length between these terminals?

A: The LCCF6-14B-L has an overall length of 2.830 inches (71.88mm), while the LCCF6-14A-L measures 2.710 inches (68.83mm). This 0.120 inch (3.05mm) difference does not impact performance in standard 1/4 inch stud mounting applications.

Q: Are the barrel and ring dimensions identical between these parts?

A: Yes. Both parts feature identical barrel inner diameter (0.220 inches / 5.59mm), barrel outer diameter (0.370 inches / 9.40mm), and ring inner diameter (0.270 inches / 6.86mm), ensuring compatibility with standard crimp tooling and stud connections.

Q: What wire gauge do these terminals accommodate?

A: Both the LCCF6-14B-L and LCCF6-14A-L are designed for 6 AWG wire termination using crimp barrel methodology.

Q: Is insulation included with these terminals?

A: No. Both parts are non-insulated terminals. Insulation must be applied separately if required by application specifications.

Request Quote (Ships tomorrow)