LCC4-14BW-L Equivalent & Substitute Parts

Part Overview

The LCC4-14BW-L is a rectangular tongue terminal connector manufactured by Panduit Corp, designed for wire gauges 2-4 AWG with a 1/4 stud connection. This non-insulated, crimp barrel terminal features electro-tin plating on copper contacts and is part of the Pan-Lug™ series. The part is currently classified as obsolete, necessitating identification of active equivalent alternatives to maintain supply chain continuity and ensure availability for new applications and replacements.

Substiute Parts

LCC4-14BW-L
Panduit CorpIn Stock: 1102LCC4-14BW-L Datasheet
LCC4-14BW-L
Current Part
LCC4-14A-L
Panduit CorpIn Stock: 1107LCC4-14A-L Datasheet
LCC4-14A-L
Similar

Key Parameters

Parameter Value
Wire Gauge 2-4 AWG
Stud/Tab Size 1/4 Stud
Terminal Type Rectangular Tongue
Termination Method Crimp, Barrel
Barrel ID 0.280" (7.11mm)
Barrel OD 0.380" (9.65mm)
Ring ID 0.270" (6.86mm)
Tab Thickness 0.090" (2.29mm)
Contact Material Copper
Contact Finish Electro-Tin
Insulation Non-Insulated

Substitute Part Grouping Explanation

Substitution of the LCC4-14BW-L is determined by strict equivalence across the following critical parameters:

Electrical Parameters:

  • Wire gauge range: 2-4 AWG
  • Stud size: 1/4 inch
  • Barrel dimensions: ID 0.280" (7.11mm), OD 0.380" (9.65mm)
  • Ring ID: 0.270" (6.86mm)
  • Contact material and finish: Copper with electro-tin plating

Mechanical Parameters:

  • Terminal type: Rectangular tongue
  • Termination method: Crimp, barrel
  • Tab thickness: 0.090" (2.29mm)
  • Mounting type: Free hanging (in-line)
  • Insulation: Non-insulated

Compliance Parameters:

  • RoHS3 compliance
  • REACH unaffected status
  • ECCN: EAR99
  • HTSUS: 8536.90.4000

The substitute part LCC4-14A-L maintains all critical electrical and mechanical parameters while offering active product status and current availability.

Parameter Comparison

Parameter LCC4-14BW-L (Main Part) LCC4-14A-L (Substitute)
Manufacturer Panduit Corp Panduit Corp
Series Pan-Lug™ Pan-Lug™
Product Status Obsolete Active
Wire Gauge 2-4 AWG 2-4 AWG
Stud/Tab Size 1/4 Stud 1/4 Stud
Terminal Type Rectangular Tongue Rectangular Tongue
Terminal Style Two Stud Holes Two Stud Holes
Tab Thickness 0.090" (2.29mm) 0.090" (2.29mm)
Length - Overall 2.630" (66.80mm) 2.580" (65.53mm)
Width - Outer Edges 0.550" (13.97mm) 0.550" (13.97mm)
Mounting Type Free Hanging (In-Line) Free Hanging (In-Line)
Termination Crimp, Barrel Crimp, Barrel
Insulation Non-Insulated Non-Insulated
Color Gray Gray
Contact Finish Electro-Tin Electro-Tin
Contact Material Copper Copper
Diameter - Barrel ID 0.280" (7.11mm) 0.280" (7.11mm)
Diameter - Barrel OD 0.380" (9.65mm) 0.380" (9.65mm)
Diameter - Ring ID 0.270" (6.86mm) 0.270" (6.86mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8536.90.4000 8536.90.4000

Engineering Selection Recommendations

The LCC4-14A-L serves as the direct substitute for the obsolete LCC4-14BW-L. Both parts are manufactured by Panduit Corp within the Pan-Lug™ series and maintain identical electrical and mechanical specifications across all critical parameters including wire gauge, stud size, barrel dimensions, contact material, and termination method.

The primary distinction is product status: LCC4-14BW-L is obsolete while LCC4-14A-L is active. The LCC4-14A-L offers current manufacturing support, documented availability, and compliance with RoHS3 and REACH requirements. Both parts are classified under ECCN EAR99 and HTSUS 8536.90.4000.

The overall length differs by 0.050" (1.27mm), with LCC4-14A-L measuring 2.580" (65.53mm) compared to 2.630" (66.80mm) for LCC4-14BW-L. This dimensional variance does not affect electrical performance or mechanical compatibility with 1/4 stud connections and remains within acceptable tolerances for rectangular tongue terminal applications.

Frequently Asked Questions (FAQ)

Q: Can LCC4-14A-L be used as a direct replacement for LCC4-14BW-L?

A: Yes. Both parts share identical wire gauge (2-4 AWG), stud size (1/4), barrel dimensions, contact material and finish, termination method, and tab thickness. The LCC4-14A-L is the active equivalent.

Q: What is the significance of the length difference between these parts?

A: The LCC4-14A-L is 0.050" (1.27mm) shorter overall. This dimensional difference does not affect electrical performance or mechanical compatibility with standard 1/4 stud connections and mounting configurations.

Q: Are both parts RoHS and REACH compliant?

A: Yes. Both LCC4-14BW-L and LCC4-14A-L are ROHS3 compliant and REACH unaffected.

Q: What wire gauges are supported by these terminals?

A: Both terminals support wire gauges 2-4 AWG with crimp barrel termination.

Q: Are these terminals insulated?

A: No. Both LCC4-14BW-L and LCC4-14A-L are non-insulated rectangular tongue terminals.

Q: What is the contact material and finish?

A: Both parts feature copper contacts with electro-tin plating for corrosion resistance and electrical conductivity.

Q: Why is LCC4-14BW-L classified as obsolete?

A: Obsolete status indicates the part is no longer in active production. The LCC4-14A-L provides equivalent functionality with current manufacturing and supply chain support.

Request Quote (Ships tomorrow)