Request Quote
(Ships tomorrow)
LCAX650-12F-6 Equivalent & Substitute Parts
Part Overview
The LCAX650-12F-6 is a terminal connector manufactured by Panduit Corp, classified as a rectangular tongue terminal designed for 650MCM (kcmil) wire gauge applications with a 1/2 stud connection. This component is part of the Pan-Lug™ series and features a non-insulated copper construction with electro-tin contact finish.
The LCAX650-12F-6 carries an Obsolete product status. Identifying equivalent and substitute parts is necessary to maintain system continuity, ensure procurement availability, and support ongoing maintenance and replacement requirements for installations utilizing this terminal connector.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Wire Gauge | 650MCM (kcmil) |
| Stud/Tab Size | 1/2 Stud |
| Terminal Type | Rectangular Tongue |
| Terminal Style | Single Stud Hole |
| Tab Thickness | 0.300" (7.62mm) |
| Termination Method | Crimp, Barrel |
| Contact Material | Copper |
| Contact Finish | Electro-Tin |
| Insulation | Non-Insulated |
| Diameter - Barrel ID | 1.050" (26.67mm) |
| Diameter - Barrel OD | 1.350" (34.29mm) |
| Diameter - Ring ID | 0.530" (13.46mm) |
| Width - Outer Edges | 1.950" (49.53mm) |
| Color | Black |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the LCAX650-12F-6 is determined by strict alignment of the following critical parameters:
Wire Gauge Compatibility: The substitute part must support 650MCM (kcmil) wire gauge to ensure proper current-carrying capacity and mechanical fit within the barrel crimp area.
Stud/Tab Size: The 1/2 stud connection point is a fixed mechanical interface requirement. Substitute parts must maintain this stud diameter to ensure compatibility with mating hardware and mounting structures.
Terminal Type and Style: The rectangular tongue configuration with single stud hole design defines the mechanical form factor. Substitutes must preserve this geometry to maintain installation compatibility.
Electrical and Material Properties: Contact material (copper), contact finish (electro-tin), and insulation status (non-insulated) must remain consistent to preserve electrical performance and corrosion resistance characteristics.
Dimensional Specifications: Barrel inner diameter (1.050"), barrel outer diameter (1.350"), ring inner diameter (0.530"), tab thickness (0.300"), and width (1.950") are fixed mechanical constraints that determine wire accommodation and mounting interface compatibility.
Compliance Requirements: RoHS3 compliance status must be maintained for regulatory and procurement consistency.
The LCAX650-12-6 qualifies as a substitute based on complete alignment with all critical parameters listed above.
Parameter Comparison
| Parameter | LCAX650-12F-6 (Main Part) | LCAX650-12-6 (Substitute) |
|---|---|---|
| Manufacturer | Panduit Corp | Panduit Corp |
| Category | Terminals | Terminals |
| Series | Pan-Lug™ | Pan-Lug™ |
| Product Status | Obsolete | Active |
| Terminal Type | Rectangular Tongue | Rectangular Tongue |
| Stud/Tab Size | 1/2 Stud | 1/2 Stud |
| Terminal Style | Single Stud Hole | Single Stud Hole |
| Tab Thickness | 0.300" (7.62mm) | 0.300" (7.62mm) |
| Wire Gauge | 650MCM (kcmil) | 650MCM (kcmil) |
| Termination | Crimp, Barrel | Crimp, Barrel |
| Contact Material | Copper | Copper |
| Contact Finish | Electro-Tin | Electro-Tin |
| Insulation | Non-Insulated | Non-Insulated |
| Color | Black | Black |
| Diameter - Barrel ID | 1.050" (26.67mm) | 1.050" (26.67mm) |
| Diameter - Barrel OD | 1.350" (34.29mm) | 1.350" (34.29mm) |
| Diameter - Ring ID | 0.530" (13.46mm) | 0.530" (13.46mm) |
| Width - Outer Edges | 1.950" (49.53mm) | 1.950" (49.53mm) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8536.90.4000 | 8536.90.4000 |
Engineering Selection Recommendations
The LCAX650-12-6 is the direct substitute for the obsolete LCAX650-12F-6. Both parts share identical electrical and mechanical specifications across all critical parameters, including wire gauge, stud size, terminal geometry, contact materials, and dimensional tolerances.
The primary distinction between these parts is product status: the LCAX650-12F-6 is classified as Obsolete, while the LCAX650-12-6 maintains Active status. This status difference reflects current manufacturing availability and supply chain support.
Both parts maintain ROHS3 compliance, REACH Unaffected status, and EAR99 export classification, ensuring regulatory consistency for procurement and deployment.
The LCAX650-12-6 is suitable for direct replacement in applications currently utilizing the LCAX650-12F-6, with no modifications to installation procedures, mating hardware, or electrical performance characteristics required.
Frequently Asked Questions (FAQ)
Q: Can the LCAX650-12-6 be used as a direct replacement for the LCAX650-12F-6?
A: Yes. The LCAX650-12-6 is electrically and mechanically equivalent to the LCAX650-12F-6. All critical parameters—wire gauge (650MCM), stud size (1/2), terminal type, contact materials, and dimensional specifications—are identical between the two parts.
Q: What is the primary difference between these two part numbers?
A: The LCAX650-12F-6 is classified as Obsolete, while the LCAX650-12-6 is Active. This reflects current manufacturing and supply chain availability. The electrical and mechanical specifications are identical.
Q: Are there any packaging differences between the LCAX650-12F-6 and LCAX650-12-6?
A: The LCAX650-12F-6 packaging specification is not provided in the technical data. The LCAX650-12-6 is supplied in Bulk packaging. Confirm packaging requirements with your procurement specifications.
Q: Do both parts meet the same regulatory compliance standards?
A: Yes. Both the LCAX650-12F-6 and LCAX650-12-6 are ROHS3 Compliant, REACH Unaffected, and classified under ECCN EAR99 with HTSUS code 8536.90.4000.
Q: What wire gauge do these terminals support?
A: Both terminals are rated for 650MCM (kcmil) wire gauge applications.
Q: What is the stud connection size for these terminals?
A: Both terminals feature a 1/2 stud connection point for mating with corresponding hardware.
Q: Are these terminals insulated or non-insulated?
A: Both terminals are non-insulated, featuring bare copper construction with electro-tin contact finish.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts