LA-511P Equivalent & Substitute Parts Reference

Part Overview

The LA-511P (Panasonic Industrial Automation Sales) is an obsolete optical sensor module with a sensing distance of 19.685" (500mm), NPN open collector output, and wire leads for chassis mounting. As the part is listed as obsolete, it is necessary to reference substitute models to ensure continued design support, inventory replenishment, and long-term repair options within the optical sensor product category.

Substiute Parts

LA-511P
Panasonic Industrial Automation SalesIn Stock: 1203LA-511P Datasheet
LA-511P
Current Part
HL-T1010F
Panasonic Industrial Automation SalesIn Stock: 805HL-T1010F Datasheet
HL-T1010F
Similar

Key Parameters

Parameter LA-511P
Category Optical Sensors
Manufacturer Panasonic Industrial Automation Sales
Sensing Distance 19.685" (500mm)
Output Configuration NPN - Open Collector
Operating Temperature 0°C ~ 50°C
RoHS Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Package / Case Module, Wire Leads

Substitute Part Grouping Explanation

Substitute parts are grouped strictly based on the following allowed parameters: category (optical sensors), manufacturer, sensing distance, output configuration, operating temperature range, and compliance status. Only substitutes matching these parameters are considered equivalent or suitable for replacement in the same application context.

Parameter Comparison

Parameter LA-511P HL-T1010F
Category Optical Sensors Optical Sensors
Manufacturer Panasonic Industrial Automation Sales Panasonic Industrial Automation Sales
Sensing Distance 19.685" (500mm) 19.685" (500mm)
Operating Temperature 0°C ~ 50°C 0°C ~ 50°C
RoHS Status RoHS Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

The LA-511P is marked obsolete, while HL-T1010F is active and meets RoHS compliance and MSL 1 requirements. Selection between these parts based strictly on available data should prioritize active status, matching sensing distance, and regulatory compliance.

Frequently Asked Questions (FAQ)

Q1. What criteria are used to determine a valid substitute for LA-511P?
A1. Substitutes are selected based on matching category, manufacturer, sensing distance, operating temperature range, RoHS compliance status, and moisture sensitivity level.

Q2. Does HL-T1010F match LA-511P in terms of sensing performance?
A2. HL-T1010F offers the same sensing distance and operates over the same temperature range as LA-511P.

Q3. Are there compatibility concerns with environmental compliance?
A3. Both models are compliant with RoHS and feature a Moisture Sensitivity Level (MSL) of 1 (Unlimited).

Q4. How does packaging and connection approach differ between the two models?
A4. LA-511P features wire leads while HL-T1010F uses a cable connection; packaging details differ (Bulk vs. Box).

Q5. Is the output configuration the same for both parts?
A5. Output configuration is different: LA-511P uses NPN - Open Collector, while HL-T1010F provides Analog output. Substitution is based only on parameters supplied; output configuration must be considered for system compatibility.

Request Quote (Ships tomorrow)