LA-511 Equivalent & Substitute Parts Reference

Part Overview

The Panasonic Industrial Automation Sales LA-511 is an optical sensor module designed for through-beam sensing applications, capable of detecting objects up to a 19.685" (500mm) distance. It features an NPN open-collector output, chassis mount configuration, and operates within a 12V to 24V supply voltage. The LA-511 is now classified as obsolete, making it necessary to identify alternative optical sensor models with comparable parameters for applications requiring replacements or ongoing support.

Substiute Parts

LA-511
Panasonic Industrial Automation SalesIn Stock: 850LA-511 Datasheet
LA-511
Current Part
HL-T1010F
Panasonic Industrial Automation SalesIn Stock: 805HL-T1010F Datasheet
HL-T1010F
Similar

Key Parameters

ParameterLA-511
ManufacturerPanasonic Industrial Automation Sales
CategoryOptical Sensors
SeriesLA
Part StatusObsolete
Sensing MethodThrough-Beam
Sensing Distance19.685" (500mm)
Output ConfigurationNPN - Open Collector
Mounting TypeChassis Mount
Current - Supply35 mA
Voltage - Supply12V ~ 24V
Response Time500µs
Operating Temperature0°C ~ 50°C
Package / CaseModule, Wire Leads
RoHS StatusRoHS Compliant
Moisture Sensitivity Level (MSL)1 (Unlimited)
ECCNEAR99
HTSUS8543.70.9860

Substitute Part Grouping Explanation

Substitute identification is strictly conducted using parameters that directly define the function, electrical/mechanical compatibility, and compliance of the optical sensors. The following key parameters form the basis for evaluating suitable replacements:

  • Sensing Distance
  • Sensing Method
  • Output Configuration
  • Operating Temperature
  • Package / Case
  • RoHS Status
  • Moisture Sensitivity Level (MSL)
  • Inventory/Availability
  • Manufacturer and Product Category

Only parts which match or closely align with these allowed electrical, mechanical, and compliance parameters are included as substitutes.

Parameter Comparison

Parameter LA-511 HL-T1010F
Manufacturer Panasonic Industrial Automation Sales Panasonic Industrial Automation Sales
Category Optical Sensors Optical Sensors
Sensing Method Through-Beam Reflective, Diffuse
Sensing Distance 19.685" (500mm) 19.685" (500mm)
Output Configuration NPN - Open Collector Analog
Operating Temperature 0°C ~ 50°C 0°C ~ 50°C
RoHS Status RoHS Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
Inventory 757 Pcs New Original In Stock 727 Pcs New Original In Stock
Part Status/Product Status Obsolete Active
Package / Case Module, Wire Leads Box

Engineering Selection Recommendations

The LA-511 is listed as obsolete, whereas the HL-T1010F is identified as active and fulfills all listed regulatory compliance requirements. Selection of available, RoHS-compliant, and MSL 1 (Unlimited) substitute parts is based strictly on matching status and compliance as specified.

Frequently Asked Questions (FAQ)

Q1: What are the primary criteria for selecting an equivalent or substitute optical sensor for LA-511?
A1: The principal selection criteria are sensing distance, sensing method, output configuration, operating temperature range, package/case type, RoHS status, and moisture sensitivity level.

Q2: Does the HL-T1010F have the same sensing method as the LA-511?
A2: The LA-511 utilizes a through-beam sensing method; the HL-T1010F uses a reflective, diffuse method. Both share the same sensing distance.

Q3: Are package/case and mounting types identical between LA-511 and HL-T1010F?
A3: The LA-511 specifies a “Module, Wire Leads” format, while the HL-T1010F is identified as supplied in a box. Only the explicit packaging description from the input can be referenced.

Q4: How does output configuration differ between the two parts?
A4: The LA-511 features an NPN open-collector output. The HL-T1010F provides an analog output.

Q5: Are both parts RoHS compliant and available at MSL 1?
A5: Both the LA-511 and HL-T1010F are RoHS compliant and have a Moisture Sensitivity Level of 1 (Unlimited).

Q6: What is the operational temperature range for both sensors?
A6: Both sensors operate over a 0°C ~ 50°C temperature range.

Request Quote (Ships tomorrow)