Request Quote
(Ships tomorrow)
LA-510D Optical Sensor 500MM Module - Equivalent & Substitute Parts
Part Overview
The LA-510D is an optical sensor module manufactured by Panasonic Industrial Automation Sales, designed for 500mm (19.685") sensing distance applications. This component features NPN open collector output configuration with 12V to 24V supply voltage operation. The LA-510D is classified as obsolete, making identification of functionally equivalent substitute components necessary for ongoing system maintenance and new design implementations.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | LA-510D |
| Manufacturer | Panasonic Industrial Automation Sales |
| Category | Optical Sensors |
| Sensing Distance | 19.685" (500mm) |
| Output Configuration | NPN - Open Collector |
| Voltage - Supply | 12V ~ 24V |
| Current - Supply | 35 mA |
| Response Time | 500µs |
| Operating Temperature | 0°C ~ 50°C |
| Mounting Type | Chassis Mount |
| Package / Case | Module, Wire Leads |
| Product Status | Obsolete |
| RoHS Status | RoHS Compliant |
Substitute Part Grouping Explanation
Substitute components for the LA-510D must satisfy the following critical parameters to ensure functional compatibility:
- Sensing Distance: 19.685" (500mm) - exact match required for optical path alignment
- Supply Voltage Range: 12V ~ 24V - compatible with existing power infrastructure
- Operating Temperature Range: 0°C ~ 50°C - environmental operating conditions
- RoHS Compliance: Required for regulatory and procurement alignment
- Manufacturer: Panasonic Industrial Automation Sales - maintains supply chain consistency
The HL-T1010A qualifies as a substitute based on matching sensing distance, supply voltage, operating temperature, and RoHS compliance. While the HL-T1010A employs through-beam sensing methodology and PNP output configuration (compared to the LA-510D's unspecified sensing method and NPN output), both components operate within identical electrical and environmental parameters, enabling substitution in applications where output polarity can be accommodated through circuit design.
Parameter Comparison
| Parameter | LA-510D | HL-T1010A |
|---|---|---|
| Manufacturer Part Number | LA-510D | HL-T1010A |
| Series | LA | HL-T1 |
| Sensing Distance | 19.685" (500mm) | 19.685" (500mm) |
| Voltage - Supply | 12V ~ 24V | 12V ~ 24V |
| Output Configuration | NPN - Open Collector | PNP - Open Collector |
| Operating Temperature | 0°C ~ 50°C | 0°C ~ 50°C |
| Package / Case | Module, Wire Leads | Cable Connection |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS Compliant | RoHS Compliant |
Engineering Selection Recommendations
The HL-T1010A represents the primary substitute for the obsolete LA-510D based on electrical parameter alignment and active product status. Both components maintain identical supply voltage ranges (12V ~ 24V) and operating temperature specifications (0°C ~ 50°C), with both achieving RoHS compliance.
The principal design consideration involves output configuration: the LA-510D provides NPN open collector output, while the HL-T1010A provides PNP open collector output. Circuit integration must accommodate this polarity difference through appropriate pull-up resistor configuration and signal conditioning logic.
The HL-T1010A's through-beam sensing methodology and cable connection interface differ from the LA-510D's module wire lead configuration. These differences require mechanical and optical path reassessment during integration but do not preclude functional substitution where sensing distance requirements remain at 500mm.
Frequently Asked Questions (FAQ)
Q: Can the HL-T1010A directly replace the LA-510D without circuit modification?
A: Direct physical replacement is not possible due to different connection methods (cable versus wire leads) and output polarity (PNP versus NPN). Circuit redesign is required to accommodate the PNP output configuration and cable interface.
Q: Are the sensing distances identical between these components?
A: Both components operate at 19.685" (500mm) sensing distance, meeting this critical parameter requirement.
Q: What is the primary reason for substitution?
A: The LA-510D is classified as obsolete. The HL-T1010A maintains active product status with identical electrical operating parameters, ensuring long-term supply availability.
Q: Do both components meet RoHS compliance requirements?
A: Both the LA-510D and HL-T1010A are RoHS compliant, satisfying regulatory requirements for new designs and procurement.
Q: How does the through-beam sensing method of the HL-T1010A differ from the LA-510D?
A: The HL-T1010A employs through-beam sensing methodology, requiring transmitter and receiver alignment across the sensing path. The LA-510D's sensing method is not specified in available documentation. Application requirements determine whether through-beam methodology is compatible with existing optical path design.
Q: What supply voltage range do these components support?
A: Both components operate across 12V to 24V supply voltage range, providing compatibility with standard industrial control power supplies.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts