L6006L6TP TRIAC Equivalent & Substitute Parts

Part Overview

The L6006L6TP is a Logic-Sensitive Gate TRIAC manufactured by Littelfuse Inc., rated for 600V off-state voltage and 6A on-state current in a through-hole TO-220-3 package. This component is classified as Active product status with full RoHS3 compliance and unlimited moisture sensitivity level. Alternative equivalent parts are necessary to address supply chain flexibility, inventory availability, and procurement optimization while maintaining identical electrical and mechanical specifications.

Substiute Parts

L6006L6TP
Littelfuse Inc.In Stock: 2620L6006L6TP Datasheet
L6006L6TP
Current Part
L6006L5TP
Littelfuse Inc.In Stock: 2350L6006L5TP Datasheet
L6006L5TP
Parametric Equivalent

Key Parameters

Parameter Value
Triac Type Logic - Sensitive Gate
Voltage - Off State 600 V
Current - On State (It (RMS)) (Max) 6 A
Voltage - Gate Trigger (Vgt) (Max) 1.3 V
Current - Gate Trigger (Igt) (Max) 5 mA
Current - Hold (Ih) (Max) 10 mA
Current - Non Rep. Surge 50, 60Hz (Itsm) 50A, 60A
Operating Temperature Range -40°C ~ 110°C (TJ)
Mounting Type Through Hole
Package / Case TO-220-3 Full Pack, Isolated Tab
Supplier Device Package ITO-220AB

Substitute Part Grouping Explanation

Substitution of the L6006L6TP is determined by strict equivalence across all critical electrical and mechanical parameters. The substitute part L6006L5TP qualifies as a direct equivalent based on the following criteria:

  • Identical Triac Type: Logic - Sensitive Gate
  • Identical voltage rating: 600V off-state
  • Identical current rating: 6A on-state (RMS maximum)
  • Identical gate trigger specifications: 1.3V maximum gate trigger voltage, 5mA maximum gate trigger current
  • Identical hold current: 10mA maximum
  • Identical surge current ratings: 50A and 60A for 50Hz and 60Hz respectively
  • Identical operating temperature range: -40°C to 110°C
  • Identical mounting configuration: Through-hole
  • Identical package designation: TO-220-3 Full Pack, Isolated Tab (ITO-220AB)

Parameter Comparison

Parameter L6006L6TP L6006L5TP Match
Manufacturer Littelfuse Inc. Littelfuse Inc. Yes
Category Thyristors Thyristors Yes
Triac Type Logic - Sensitive Gate Logic - Sensitive Gate Yes
Voltage - Off State 600 V 600 V Yes
Current - On State (It (RMS)) (Max) 6 A 6 A Yes
Voltage - Gate Trigger (Vgt) (Max) 1.3 V 1.3 V Yes
Current - Gate Trigger (Igt) (Max) 5 mA 5 mA Yes
Current - Hold (Ih) (Max) 10 mA 10 mA Yes
Current - Non Rep. Surge 50, 60Hz (Itsm) 50A, 60A 50A, 60A Yes
Operating Temperature -40°C ~ 110°C (TJ) -40°C ~ 110°C (TJ) Yes
Mounting Type Through Hole Through Hole Yes
Package / Case TO-220-3 Full Pack, Isolated Tab TO-220-3 Full Pack, Isolated Tab Yes
Supplier Device Package ITO-220AB ITO-220AB Yes
RoHS Status ROHS3 Compliant ROHS3 Compliant Yes
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) Yes
REACH Status REACH Unaffected REACH Unaffected Yes
Product Status Active Active Yes

Engineering Selection Recommendations

Both L6006L6TP and L6006L5TP are Active product status components with full RoHS3 compliance and REACH Unaffected designation. Selection between these parts is based on inventory availability and procurement lead times rather than technical differentiation. The L6006L6TP currently maintains 2526 pieces in stock, while the L6006L5TP maintains 2300 pieces. Both parts carry identical certifications and regulatory compliance status, making either suitable for applications requiring 600V, 6A Logic-Sensitive Gate TRIAC functionality in TO-220-3 through-hole configurations.

Frequently Asked Questions (FAQ)

Q: Can L6006L5TP be used as a direct replacement for L6006L6TP?

A: Yes. The L6006L5TP is a parametric equivalent with identical electrical ratings, gate trigger specifications, surge current capabilities, operating temperature range, and package configuration. No circuit modifications are required.

Q: Are there any differences in compliance or certifications between these parts?

A: No. Both parts carry identical RoHS3 compliance, REACH Unaffected status, and unlimited moisture sensitivity level (MSL 1). Regulatory and environmental compliance is equivalent.

Q: What determines substitution eligibility for these TRIAC components?

A: Substitution is determined by matching all critical parameters: off-state voltage rating, on-state current rating, gate trigger voltage and current specifications, hold current, surge current ratings, operating temperature range, mounting type, and package designation. Both parts meet all these criteria identically.

Q: Are the TO-220-3 packages physically interchangeable?

A: Yes. Both parts use the TO-220-3 Full Pack with Isolated Tab configuration (ITO-220AB supplier package designation), ensuring mechanical and thermal compatibility in PCB layouts and heat sink mounting applications.

Q: What is the difference between L6006L6TP and L6006L5TP part numbers?

A: The part numbers differ only in the fifth character (6 versus 5). Both designations refer to equivalent Logic-Sensitive Gate TRIAC devices within the Littelfuse Lxx06xx series with identical electrical and mechanical specifications.

Request Quote (Ships tomorrow)