Request Quote
(Ships tomorrow)
L18P030D15 Hall Effect Current Sensor - Equivalent & Substitute Parts
Part Overview
The L18P030D15 is a 30A Hall Effect open-loop bidirectional current sensor manufactured by Tamura. This through-hole module provides ratiometric voltage output for AC/DC current measurement across a frequency range of DC to 100kHz. The part is classified as obsolete, making equivalent and substitute parts necessary for ongoing design support and procurement continuity. The L18P030D15-OP represents the active production equivalent with enhanced specifications and improved supply voltage tolerance.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | L18P030D15 |
| Manufacturer | Tamura |
| Current Sensing Range | 30A |
| Sensor Type | Hall Effect, Open Loop |
| Number of Channels | 1 |
| Output Type | Ratiometric, Voltage |
| Measurement Type | AC/DC |
| Polarization | Bidirectional |
| Frequency Range | DC ~ 100kHz |
| Linearity | ±1% |
| Supply Voltage | ±15V |
| Response Time | 5µs |
| Maximum Supply Current | 15mA |
| Operating Temperature Range | -30°C ~ 80°C |
| Mounting Type | Through Hole |
| Package Type | Module |
| RoHS Status | RoHS Compliant |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution logic for the L18P030D15 is based on the following critical parameters that determine functional equivalence:
Primary Substitution Criteria:
- Sensor Type: Hall Effect, Open Loop
- Output Type: Ratiometric, Voltage
- Measurement Type: AC/DC
- Polarization: Bidirectional
- Mounting Type: Through Hole
- Package Type: Module
- Linearity: ±1%
- Response Time: 5µs
- Operating Temperature Range: -30°C ~ 80°C
- Supply Voltage Compatibility: ±15V nominal
Current Sensing Range Grouping: Substitute parts are organized by current sensing capacity. The L18P030D15 (30A) can be substituted with the active-production L18P030D15-OP (30A). Lower current-rated sensors (L18P003D15, L18P005D15, L18P010D15, L18P025D15) share identical electrical and mechanical characteristics but differ in current measurement range and are suitable only when application requirements permit reduced current capacity.
Parameter Comparison
| Parameter | L18P030D15 | L18P030D15-OP | L18P025D15 | L18P010D15 | L18P005D15 | L18P003D15 |
|---|---|---|---|---|---|---|
| Current Sensing | 30A | 30A | 25A | 10A | 5A | 3A |
| Sensor Type | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop |
| Number of Channels | 1 | 1 | 1 | 1 | 1 | 1 |
| Output Type | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage |
| Measurement Type | AC/DC | AC/DC | AC/DC | AC/DC | AC/DC | AC/DC |
| Polarization | Bidirectional | Bidirectional | Bidirectional | Bidirectional | Bidirectional | Bidirectional |
| Frequency Range | DC ~ 100kHz | Not specified | DC ~ 100kHz | DC ~ 100kHz | DC ~ 100kHz | DC ~ 100kHz |
| Linearity | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
| Supply Voltage | ±15V | ±12V ~ 15V | ±15V | ±15V | ±15V | ±15V |
| Response Time | 5µs | 5µs | 5µs | 5µs | 5µs | 5µs |
| Maximum Supply Current | 15mA | 18mA | 15mA | 15mA | 15mA | 15mA |
| Operating Temperature | -30°C ~ 80°C | -30°C ~ 80°C | -30°C ~ 80°C | -30°C ~ 80°C | -30°C ~ 80°C | -30°C ~ 80°C |
| Mounting Type | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole |
| Package Type | Module | Module | Module | Module | Module | Module |
| RoHS Status | RoHS Compliant | ROHS3 Compliant | RoHS Compliant | RoHS Compliant | RoHS Compliant | RoHS Compliant |
| Product Status | Obsolete | Active | Obsolete | Obsolete | Obsolete | Obsolete |
Engineering Selection Recommendations
Direct Replacement (30A Current Sensing): The L18P030D15-OP is the recommended substitute for the obsolete L18P030D15. Both parts maintain identical 30A current sensing capacity and share all critical electrical parameters. The L18P030D15-OP offers active product status, ROHS3 compliance (enhanced environmental standard), and improved supply voltage tolerance (±12V ~ 15V versus ±15V nominal). Maximum supply current increases from 15mA to 18mA, representing improved operational margin. This part is suitable for direct PCB replacement without design modification.
Alternative Selections (Reduced Current Sensing): The L18P025D15, L18P010D15, L18P005D15, and L18P003D15 are parametric equivalents that share all electrical and mechanical characteristics with the L18P030D15 except for current sensing range. These parts are applicable only when application requirements permit operation at reduced current measurement capacity. All alternative selections maintain identical response time (5µs), linearity (±1%), operating temperature range (-30°C ~ 80°C), and output characteristics (ratiometric voltage).
Compliance Considerations: All substitute parts maintain RoHS compliance. The L18P030D15-OP provides enhanced ROHS3 certification. All parts are classified under ECCN EAR99 and HTSUS 9030.33.3800.
Frequently Asked Questions (FAQ)
Q: Can the L18P030D15-OP be used as a direct replacement for the L18P030D15? A: Yes. The L18P030D15-OP is the active production equivalent with identical 30A current sensing capacity and all critical electrical parameters. The part features improved supply voltage tolerance and ROHS3 compliance. No design modification is required.
Q: What is the difference between the L18P030D15 and lower-rated sensors like the L18P025D15? A: The primary difference is current sensing range. The L18P030D15 measures up to 30A, while the L18P025D15 measures up to 25A. All other electrical characteristics—sensor type, output format, response time, linearity, operating temperature, and supply voltage—are identical. Lower-rated sensors are suitable only when application current requirements are within their specified range.
Q: Are the L18P030D15 and L18P030D15-OP pin-compatible? A: Both parts are through-hole modules with identical mounting type and package classification. Pin compatibility is confirmed by matching electrical specifications and identical functional characteristics.
Q: What packaging options are available for the L18P030D15-OP? A: The L18P030D15-OP is supplied in Tray packaging. The obsolete L18P030D15 was supplied in standard packaging. Verify packaging requirements for your procurement process.
Q: Can I substitute a lower current-rated sensor if my application only requires 10A measurement? A: Yes, if your application requires only 10A measurement capacity, the L18P010D15 is a parametric equivalent. All electrical and mechanical characteristics remain identical to the L18P030D15. Verify that your signal processing and output scaling accommodate the different current range.
Q: What is the frequency response of these current sensors? A: The L18P030D15 and all lower-rated equivalents (L18P025D15, L18P010D15, L18P005D15, L18P003D15) operate across DC to 100kHz frequency range. The L18P030D15-OP does not specify frequency range in available documentation.
Q: Are these sensors suitable for both AC and DC current measurement? A: Yes. All parts are rated for AC/DC measurement with bidirectional polarization, enabling measurement of current flow in both directions.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts