L18P015D15 Hall Effect Current Sensor - Equivalent & Substitute Parts

Part Overview

The L18P015D15 is a 15A Hall Effect open-loop bidirectional current sensor manufactured by Tamura, designed for AC/DC current measurement applications. This module provides ratiometric voltage output with ±1% linearity and operates across a frequency range of DC to 100kHz. The part is classified as obsolete, necessitating identification of equivalent and substitute components for ongoing design requirements and procurement continuity.

Substiute Parts

L18P015D15
TamuraIn Stock: 3747L18P015D15 Datasheet
L18P015D15
Current Part
L18P015D15-OP
TamuraIn Stock: 1164L18P015D15-OP Datasheet
L18P015D15-OP
MFR Recommended
L18P003D15
TamuraIn Stock: 1959L18P003D15 Datasheet
L18P003D15
Parametric Equivalent
L18P005D15
TamuraIn Stock: 1481L18P005D15 Datasheet
L18P005D15
Parametric Equivalent
L18P010D15
TamuraIn Stock: 1962L18P010D15 Datasheet
L18P010D15
Parametric Equivalent
HX 15-P
LEM USA Inc.In Stock: 1080HX 15-P Datasheet
HX 15-P
Similar

Key Parameters

Parameter Value
Manufacturer Part Number L18P015D15
Manufacturer Tamura
Current - Sensing 15A
Sensor Type Hall Effect, Open Loop
Number of Channels 1
Output Type Ratiometric, Voltage
For Measuring AC/DC
Voltage - Supply ±15V
Frequency Range DC ~ 100kHz
Linearity ±1%
Response Time 5µs
Current - Supply (Max) 15mA
Operating Temperature -30°C ~ 80°C
Polarization Bidirectional
Mounting Type Through Hole
Package / Case Module
Product Status Obsolete
RoHS Status RoHS Compliant

Substitute Part Grouping Explanation

Substitution of the L18P015D15 is determined by the following critical parameters:

Primary Substitution Criteria:

  • Current sensing rating (15A nominal)
  • Hall Effect, open-loop sensor technology
  • Ratiometric voltage output configuration
  • Single-channel architecture
  • Bidirectional polarization capability
  • Through-hole module mounting
  • AC/DC measurement capability

Secondary Compatibility Factors:

  • Supply voltage compatibility (±15V nominal or ±12V ~ 15V range)
  • Response time performance (5µs baseline)
  • Operating temperature range (-30°C ~ 80°C minimum)
  • Linearity specification (±1%)
  • RoHS compliance status

Substitute parts are grouped into three categories: MFR Recommended (direct replacement with active status), Parametric Equivalents (same current rating, obsolete status), and Similar alternatives (different manufacturer, comparable specifications).

Parameter Comparison

Parameter L18P015D15 L18P015D15-OP L18P003D15 L18P005D15 L18P010D15 HX 15-P
Manufacturer Tamura Tamura Tamura Tamura Tamura LEM USA Inc.
Current - Sensing 15A 15A 3A 5A 10A 15A
Sensor Type Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop
Number of Channels 1 1 1 1 1 1
Output Type Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage
For Measuring AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC
Voltage - Supply ±15V ±12V ~ 15V ±15V ±15V ±15V ±15V
Frequency Range DC ~ 100kHz Not specified DC ~ 100kHz DC ~ 100kHz DC ~ 100kHz 50kHz
Linearity ±1% ±1% ±1% ±1% ±1% ±1%
Response Time 5µs 5µs 5µs 5µs 5µs 3µs
Current - Supply (Max) 15mA 18mA 15mA 15mA 15mA 15mA
Operating Temperature -30°C ~ 80°C -30°C ~ 80°C -30°C ~ 80°C -30°C ~ 80°C -30°C ~ 80°C -25°C ~ 85°C
Polarization Bidirectional Bidirectional Bidirectional Bidirectional Bidirectional Bidirectional
Mounting Type Through Hole Through Hole Through Hole Through Hole Through Hole Through Hole
Package / Case Module Module Module Module Module Module
Product Status Obsolete Active Obsolete Obsolete Obsolete Not For New Designs
RoHS Status RoHS Compliant RoHS Compliant RoHS Compliant RoHS Compliant RoHS Compliant RoHS Compliant

Engineering Selection Recommendations

Primary Recommendation: L18P015D15-OP

The L18P015D15-OP is the MFR recommended substitute and represents the direct evolution of the L18P015D15. This part maintains identical current sensing capability (15A), sensor technology (Hall Effect, open-loop), output configuration (ratiometric voltage), and mechanical compatibility (through-hole module). The L18P015D15-OP carries Active product status, ensuring long-term availability and supply chain continuity. Supply voltage range extends to ±12V ~ 15V, providing broader operational flexibility. Maximum supply current increases to 18mA. RoHS compliance is maintained. This part is suitable for new designs and ongoing production.

Secondary Recommendation: HX 15-P

The HX 15-P, manufactured by LEM USA Inc., provides equivalent current sensing (15A) and maintains all core functional parameters. This part is classified as Not For New Designs but remains available for legacy system support. Response time is superior at 3µs versus 5µs. Operating temperature range extends to -25°C ~ 85°C. Frequency bandwidth is specified at 50kHz, which is lower than the L18P015D15 specification of DC ~ 100kHz. RoHS compliance is confirmed. Selection of this part requires justification for applications where the 50kHz frequency limitation is acceptable.

Parametric Equivalents: L18P003D15, L18P005D15, L18P010D15

These parts share identical sensor technology, output type, and mechanical characteristics but differ in current sensing ratings (3A, 5A, and 10A respectively). These components are classified as Obsolete. Selection of these parts is appropriate only for applications where the lower current rating is sufficient and where the design can accommodate the reduced sensing capability. All three maintain ±1% linearity, 5µs response time, and -30°C ~ 80°C operating temperature range.

Frequently Asked Questions (FAQ)

Q: Can L18P015D15-OP be used as a direct replacement for L18P015D15?

A: Yes. The L18P015D15-OP is the MFR recommended substitute with identical current sensing (15A), sensor type (Hall Effect, open-loop), output configuration (ratiometric voltage), and mechanical mounting (through-hole module). Supply voltage compatibility is maintained at ±15V nominal operation within the ±12V ~ 15V range. Response time, linearity, and operating temperature specifications are equivalent.

Q: What is the difference between L18P015D15 and L18P015D15-OP?

A: The primary differences are product status (Obsolete versus Active) and packaging (bulk versus tray). The L18P015D15-OP features a slightly extended supply voltage range (±12V ~ 15V versus ±15V) and marginally higher maximum supply current (18mA versus 15mA). Functional performance parameters including current sensing, response time, linearity, and operating temperature are identical.

Q: Can lower-rated current sensors (L18P003D15, L18P005D15, L18P010D15) substitute for the 15A L18P015D15?

A: No. These parts have different current sensing ratings (3A, 5A, 10A respectively) and cannot measure 15A signals. Selection of these parts is limited to applications where the lower current rating is appropriate for the measurement requirement. All share identical sensor technology and output configuration.

Q: Is HX 15-P compatible with L18P015D15?

A: HX 15-P provides equivalent 15A current sensing and maintains core functional parameters (Hall Effect, open-loop, ratiometric voltage output, bidirectional, through-hole module). However, frequency bandwidth is limited to 50kHz compared to L18P015D15 specification of DC ~ 100kHz. Response time is superior at 3µs. Operating temperature range is extended to -25°C ~ 85°C. Selection requires confirmation that the 50kHz frequency limitation is acceptable for the application.

Q: What packaging options are available for 15A Hall Effect current sensors?

A: L18P015D15-OP is supplied in Tray packaging. L18P015D15 and lower-rated Tamura equivalents (L18P003D15, L18P005D15, L18P010D15) are supplied in Bulk packaging. HX 15-P is supplied in Tray packaging. Packaging selection depends on procurement volume and handling requirements.

Q: Are all substitute parts RoHS compliant?

A: Yes. All listed substitute parts (L18P015D15-OP, L18P003D15, L18P005D15, L18P010D15, HX 15-P) carry RoHS Compliant status, meeting environmental and regulatory requirements for electronic component manufacturing and assembly.

Q: What is the significance of product status (Obsolete, Active, Not For New Designs)?

A: Product status indicates lifecycle stage and supply availability. Active status (L18P015D15-OP) indicates current production and long-term availability suitable for new designs. Obsolete status indicates discontinued production; existing inventory may be available but future supply is not guaranteed. Not For New Designs status (HX 15-P) indicates the part remains available but is not recommended for new product development.

Request Quote (Ships tomorrow)