Tamura L07P020S05 Hall Effect Current Sensor 20A AC/DC Equivalent & Substitute Parts

Part Overview

The Tamura L07P020S05 is a Hall Effect open-loop bidirectional current sensor rated for 20A AC/DC measurement. This component is classified as obsolete, necessitating identification of active equivalent and substitute parts for ongoing design support and procurement. The L07P020S05 operates as a single-channel ratiometric voltage output module with 5V supply, suitable for applications requiring AC/DC current sensing across a frequency range of DC to 100kHz. Substitute parts are selected from the active L18PXXXS05 series, which maintains core electrical and mechanical compatibility while offering extended product lifecycle support.

Substiute Parts

L07P020S05
TamuraIn Stock: 692L07P020S05 Datasheet
L07P020S05
Current Part
L07P010S05
TamuraIn Stock: 1071L07P010S05 Datasheet
L07P010S05
Parametric Equivalent
L18P003S05
TamuraIn Stock: 813L18P003S05 Datasheet
L18P003S05
Parametric Equivalent
L18P003S05R
TamuraIn Stock: 878L18P003S05R Datasheet
L18P003S05R
Parametric Equivalent
L18P005S05
TamuraIn Stock: 908L18P005S05 Datasheet
L18P005S05
Parametric Equivalent
L18P005S05R
TamuraIn Stock: 893L18P005S05R Datasheet
L18P005S05R
Parametric Equivalent
L18P010S05
TamuraIn Stock: 1114L18P010S05 Datasheet
L18P010S05
Parametric Equivalent
L18P010S05R
TamuraIn Stock: 684L18P010S05R Datasheet
L18P010S05R
Parametric Equivalent
L18P015S05
TamuraIn Stock: 1118L18P015S05 Datasheet
L18P015S05
Parametric Equivalent
L18P015S05R
TamuraIn Stock: 1051L18P015S05R Datasheet
L18P015S05R
Parametric Equivalent
L18P020S05
TamuraIn Stock: 1110L18P020S05 Datasheet
L18P020S05
Parametric Equivalent
L18P020S05R
TamuraIn Stock: 1001L18P020S05R Datasheet
L18P020S05R
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Tamura
Sensor Type Hall Effect, Open Loop
Measurement Type AC/DC
Current Sensing Range 20A
Number of Channels 1
Output Type Ratiometric, Voltage
Frequency Response DC ~ 100kHz
Linearity ±1%
Supply Voltage 5V
Response Time 5µs
Maximum Supply Current 30mA
Operating Temperature Range -30°C ~ 80°C
Polarization Bidirectional
Mounting Type Through Hole
Package Type Module
RoHS Status RoHS Compliant

Substitute Part Grouping Explanation

Substitution of the L07P020S05 is determined by the following critical parameters that must remain constant across all equivalent parts:

Fixed Parameters (Non-Negotiable):

  • Sensor Type: Hall Effect, Open Loop
  • Measurement Type: AC/DC
  • Output Type: Ratiometric, Voltage
  • Frequency Response: DC ~ 100kHz
  • Linearity: ±1%
  • Supply Voltage: 5V
  • Response Time: 5µs
  • Operating Temperature Range: -30°C ~ 80°C
  • Polarization: Bidirectional
  • Mounting Type: Through Hole
  • Package Type: Module

Variable Parameters (Application-Dependent):

  • Current Sensing Range: 3A, 5A, 10A, 15A, 20A
  • Maximum Supply Current: 15mA or 30mA

The L18PXXXS05 series provides direct substitutes across multiple current ratings. Selection of the appropriate substitute depends on the application's actual current measurement requirement. The L18P020S05 and L18P020S05R are full functional equivalents to the L07P020S05 for 20A applications. Lower current-rated variants (L18P003S05, L18P005S05, L18P010S05, L18P015S05) serve applications with reduced current sensing needs while maintaining identical electrical characteristics and form factor.

Parameter Comparison

Parameter L07P020S05 L07P010S05 L18P003S05 L18P005S05 L18P010S05 L18P015S05 L18P020S05
Manufacturer Tamura Tamura Tamura Tamura Tamura Tamura Tamura
Series L07P L07P L18PXXXS05 L18PXXXS05 L18PXXXS05 L18PXXXS05 L18PXXXS05
Product Status Obsolete Active Active Active Active Active Active
Current Sensing 20A 10A 3A 5A 10A 15A 20A
Sensor Type Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop Hall Effect, Open Loop
Measurement Type AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC
Number of Channels 1 1 1 1 1 1 1
Output Type Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage Ratiometric, Voltage
Frequency Response DC ~ 100kHz DC ~ 100kHz DC ~ 100kHz DC ~ 100kHz DC ~ 100kHz DC ~ 100kHz DC ~ 100kHz
Linearity ±1% ±1% ±1% ±1% ±1% ±1% ±1%
Supply Voltage 5V 5V 5V 5V 5V 5V 5V
Response Time 5µs 5µs 5µs 5µs 5µs 5µs 5µs
Max Supply Current 30mA 30mA 15mA 15mA 15mA 15mA 15mA
Operating Temperature -30°C ~ 80°C -30°C ~ 80°C -30°C ~ 80°C -30°C ~ 80°C -30°C ~ 80°C -30°C ~ 80°C -30°C ~ 80°C
Polarization Bidirectional Bidirectional Bidirectional Bidirectional Bidirectional Bidirectional Bidirectional
Mounting Type Through Hole Through Hole Through Hole Through Hole Through Hole Through Hole Through Hole
Package Type Module Module Module Module Module Module Module
RoHS Status RoHS Compliant RoHS Compliant RoHS Compliant RoHS Compliant RoHS Compliant RoHS Compliant RoHS3 Compliant

Engineering Selection Recommendations

Primary Substitute for 20A Applications:

The L18P020S05 and L18P020S05R are the recommended direct replacements for the obsolete L07P020S05. Both parts maintain identical electrical specifications, frequency response, and thermal operating range. The L18P020S05 is available in bulk packaging with 1040 units in stock and carries RoHS3 compliance certification. The L18P020S05R variant is also active with 979 units available. Both support the same through-hole module form factor and 5V supply architecture.

Secondary Substitutes for Reduced Current Applications:

When application requirements permit lower current sensing ratings, the L18P series offers alternatives:

  • L18P015S05 / L18P015S05R: 15A rating, 1019 / 979 units in stock
  • L18P010S05 / L18P010S05R: 10A rating, 1005 / 663 units in stock
  • L18P005S05 / L18P005S05R: 5A rating, 887 / 812 units in stock
  • L18P003S05 / L18P003S05R: 3A rating, 775 / 835 units in stock

All L18PXXXS05 variants maintain RoHS compliance and identical electrical performance characteristics. Selection should be based on the actual maximum current measurement requirement of the application. Oversizing current rating introduces unnecessary cost; undersizing creates measurement saturation risk.

Compatibility Considerations:

The L07P010S05 remains active with 987 units in stock and serves as an alternative for 10A applications within the L07P series. However, migration to the L18PXXXS05 series is preferred due to extended product lifecycle and higher inventory availability across all current ratings.

Frequently Asked Questions (FAQ)

Q: Can the L18P020S05 directly replace the L07P020S05 in existing designs?

A: Yes. The L18P020S05 maintains identical electrical specifications, frequency response (DC ~ 100kHz), linearity (±1%), supply voltage (5V), response time (5µs), operating temperature range (-30°C ~ 80°C), and through-hole module form factor. Both are Hall Effect open-loop bidirectional sensors with ratiometric voltage output. The primary difference is product status: L07P020S05 is obsolete while L18P020S05 is active with extended availability.

Q: What is the difference between L18P020S05 and L18P020S05R?

A: Both parts are functionally equivalent with identical electrical and mechanical specifications. The "R" designation indicates a variant within the same product line. Both are active, RoHS compliant, and available in high quantities. Selection between them depends on supplier availability and internal part numbering requirements.

Q: Can I use a lower current-rated sensor such as L18P015S05 if my application only requires 15A measurement?

A: Yes, if your application's maximum current requirement does not exceed 15A. The L18P015S05 provides identical electrical performance, frequency response, and output characteristics as the 20A-rated variants. Using the appropriate current rating for your application optimizes cost and measurement accuracy within the sensor's linear operating range.

Q: What is the difference in maximum supply current between L07P020S05 (30mA) and L18P020S05 (15mA)?

A: The L18P020S05 operates at 15mA maximum supply current compared to 30mA for the L07P020S05. This represents improved power efficiency in the newer L18PXXXS05 series design. Both values remain well within typical circuit power budgets. Verify that your power supply can deliver the specified maximum current; the L18P020S05 requirement of 15mA is lower and presents no compatibility risk.

Q: Are all L18PXXXS05 variants pin-compatible with the L07P020S05?

A: All parts in this comparison maintain identical through-hole module form factor and 5V supply architecture. Mechanical compatibility is confirmed across the L07P and L18PXXXS05 series. Verify PCB footprint and connector specifications in your design documentation before final substitution.

Q: What is the inventory status for substitute parts?

A: The L18P020S05 has 1040 units in stock (bulk packaging). The L18P020S05R has 979 units available. All lower current-rated L18PXXXS05 variants maintain inventory above 600 units. The L07P010S05 has 987 units in stock as an alternative within the original L07P series.

Q: Do all substitute parts carry RoHS certification?

A: Yes. All L18PXXXS05 series parts carry RoHS3 compliance. The L07P020S05 and L07P010S05 carry RoHS compliance. All parts meet environmental regulatory requirements for electronic component procurement.

Request Quote (Ships tomorrow)