Equivalent & Substitute Parts Reference for KWS15-5

Part Overview

KWS15-5 by TDK-Lambda Americas Inc is an enclosed AC/DC converter providing a single 5V, 3A output at 15 W for ITE (Commercial) applications. The product is classified as obsolete. Due to the discontinued status, sourcing direct replacements or alternatives with strictly matching electrical and mechanical specifications is required for ongoing system support or maintenance.

Substiute Parts

KWS15-5
TDK-Lambda Americas IncIn Stock: 53127KWS15-5 Datasheet
KWS15-5
Current Part
KPSA15-5
TDK-Lambda Americas IncIn Stock: 956KPSA15-5 Datasheet
KPSA15-5
Direct
KWS15A-5
TDK-Lambda Americas IncIn Stock: 1266KWS15A-5 Datasheet
KWS15A-5
Direct

Key Parameters

Manufacturer Part Number Manufacturer Type Series Number of Outputs Voltage - Input Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Approval Agency Product Status
KWS15-5 TDK-Lambda Americas Inc Enclosed KW (15W) 1 85 ~ 265 VAC 5V 3A 15 W ITE (Commercial) Universal Input -10°C ~ 70°C (With Derating) 73% Through Hole 5-DIP Module 2.75" L x 1.89" W x 0.93" H (70.0mm x 48.0mm x 23.5mm) CE, CSA, TUV, UL Obsolete

Substitute Part Grouping Explanation

The substitute part selection for KWS15-5 is strictly based on the following key parameters: output voltage (5V), power rating (15 W), mounting type (Through Hole), input voltage range (85 ~ 265 VAC or similar), number of outputs (1), and ITE (Commercial) application suitability. Only those parts that precisely match these requirements can be considered suitable equivalents.

Parameter Comparison

Manufacturer Part Number Type Series Number of Outputs Voltage - Input Voltage - Output 1 Power (Watts) Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Approval Agency Product Status
KWS15-5 Enclosed KW (15W) 1 85 ~ 265 VAC 5V 15 W ITE (Commercial) Universal Input -10°C ~ 70°C (With Derating) 73% Through Hole 5-DIP Module 2.75" L x 1.89" W x 0.93" H (70.0mm x 48.0mm x 23.5mm) CE, CSA, TUV, UL Obsolete
KPSA15-5 Open Frame KPSA (15W) 1 85 ~ 264 VAC 5V 15 W ITE (Commercial) Universal Input 0°C ~ 70°C (With Derating) 75% Through Hole 4-DIP Module 2.75" L x 1.77" W x 0.79" H (69.9mm x 45.0mm x 20.1mm) CE, CSA, EN, UL Active
KWS15A-5 Enclosed KWS-A (15W) 1 85 ~ 265 VAC, 120 ~ 370 VDC 5V 15 W ITE (Commercial) Universal Input -10°C ~ 85°C (With Derating) 77% Through Hole 4-DIP Module 2.00" L x 1.00" W x 0.94" H (50.8mm x 25.4mm x 24.0mm) CE Active

Engineering Selection Recommendations

Both KPSA15-5 and KWS15A-5 share essential characteristics with KWS15-5 according to the provided parameters, including output voltage, power rating, input voltage compatibility, mounting type, and application area. Certification details and approval agency status are listed for direct suitability review. RoHS status and REACH compliance are noted where available, supporting environmental compatibility. Only stated agencies and compliance parameters should be considered for regulatory and system qualification.

Frequently Asked Questions (FAQ)

Q1: What are the defining substitution criteria for KWS15-5?
A1: Output voltage (5V), power rating (15 W), input voltage range (minimum 85 ~ 264/265 VAC), mounting type (Through Hole), single output, application (ITE Commercial), and environmental/approval agency certifications.

Q2: Are all substitute parts listed mechanically interchangeable?
A2: Mechanical interchangeability depends on package/case format and physical dimensions. KPSA15-5 and KWS15A-5 use 4-DIP Module cases, whereas KWS15-5 uses a 5-DIP Module. Size and mounting arrangement must be confirmed for fitment.

Q3: Do substitute parts maintain required regulatory approvals?
A3: Substitute parts include CE, CSA, EN, UL, or TUV certifications as stated in the parameters. Review of listed approval agencies is required for regulatory application compatibility.

Q4: Does efficiency variation affect engineering selection?
A4: Efficiency for the substitutes ranges from 75% to 77%, compared to KWS15-5 at 73%. Selection should reference system thermal and energy budget requirements as per efficiency values provided.

Q5: Is product status relevant for component selection?
A5: Both KPSA15-5 and KWS15A-5 are active products. KWS15-5 is obsolete and should be replaced in new or supported designs using substitute parts listed.

Q6: Are the environmental operating temperature ranges equivalent across all listed parts?
A6: Substitute operating temperature ranges differ: KPSA15-5 operates from 0°C ~ 70°C (with derating), while KWS15A-5 provides -10°C ~ 85°C (with derating). Requirements must be evaluated against these stated parameters.

Q7: How is mounting type addressed for substitutions?
A7: All listed parts use Through Hole mounting as per the provided parameters, maintaining compatibility with the original assembly technique.

Request Quote (Ships tomorrow)