KTY82/121,235 PTC Thermistor Equivalent & Substitute Parts

Part Overview

The KTY82/121,235 is a PTC thermistor manufactured by NXP USA Inc., rated at 990 Ohms at 25°C in a TO-236-3 (SOT-23-3) surface mount package. This component operates across a temperature range of -55°C to 150°C and is compliant with ROHS3 and REACH standards. The product is currently listed as obsolete, making equivalent substitutes necessary for new designs and ongoing production requirements.

Substiute Parts

KTY82/121,235
NXP USA Inc.In Stock: 5499KTY82/121,235 Datasheet
KTY82/121,235
Current Part
DS60R+T&R
Analog Devices Inc./Maxim IntegratedIn Stock: 15603DS60R+T&R Datasheet
DS60R+T&R
MFR Recommended
LM60QIM3/NOPB
Texas InstrumentsIn Stock: 17709LM60QIM3/NOPB Datasheet
LM60QIM3/NOPB
MFR Recommended
LM60QIM3X/NOPB
Texas InstrumentsIn Stock: 18363LM60QIM3X/NOPB Datasheet
LM60QIM3X/NOPB
MFR Recommended
LM62BIM3/NOPB
Texas InstrumentsIn Stock: 1485LM62BIM3/NOPB Datasheet
LM62BIM3/NOPB
MFR Recommended
LM62BIM3X/NOPB
National SemiconductorIn Stock: 2665LM62BIM3X/NOPB Datasheet
LM62BIM3X/NOPB
MFR Recommended
LM62CIM3X/NOPB
Texas InstrumentsIn Stock: 738LM62CIM3X/NOPB Datasheet
LM62CIM3X/NOPB
MFR Recommended
MCP9701T-E/TT
Microchip TechnologyIn Stock: 2326MCP9701T-E/TT Datasheet
MCP9701T-E/TT
MFR Recommended
TC1047AVNBTR
Microchip TechnologyIn Stock: 38220TC1047AVNBTR Datasheet
TC1047AVNBTR
MFR Recommended
TC1047VNBTR
Microchip TechnologyIn Stock: 6507TC1047VNBTR Datasheet
TC1047VNBTR
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number KTY82/121,235
Manufacturer NXP USA Inc.
Category Temperature Sensors
Product Type PTC Thermistor
Resistance @ 25°C 990 Ohms
Operating Temperature Range -55°C ~ 150°C
Package / Case TO-236-3, SC-59, SOT-23-3
Mounting Type Surface Mount
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited)
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution for the KTY82/121,235 is based on the following critical parameters:

Package Compatibility: All substitute parts must use the TO-236-3 (SOT-23-3) surface mount package to ensure mechanical and electrical compatibility with existing PCB layouts.

Sensor Type & Output: The KTY82/121,235 is a PTC thermistor with resistance-based output. Substitute parts listed are analog temperature sensors with voltage output, representing a functional shift from resistance-based to voltage-based temperature sensing. This substitution requires circuit redesign to accommodate analog voltage output instead of resistance measurement.

Operating Temperature Range: The original part operates from -55°C to 150°C. Substitute parts operate within -40°C to 125°C or 0°C to 90°C ranges, which may not cover the full lower temperature specification of the original component.

Compliance & Certification: All substitute parts maintain ROHS3 compliance and MSL Level 1 rating, ensuring environmental and moisture handling compatibility.

Product Status: Active substitute parts are preferred for new designs and long-term availability.

Parameter Comparison

Part Number Manufacturer Sensor Type Operating Temperature Output Type Package Product Status RoHS Status
KTY82/121,235 NXP USA Inc. PTC Thermistor -55°C ~ 150°C Resistance SOT-23-3 Obsolete ROHS3
DS60R+T&R Analog Devices Inc./Maxim Integrated Analog, Local -40°C ~ 125°C Analog Voltage SOT-23-3 Active ROHS3
LM60QIM3/NOPB Texas Instruments Analog, Local -40°C ~ 125°C Analog Voltage SOT-23-3 Obsolete ROHS3
LM60QIM3X/NOPB Texas Instruments Analog, Local -40°C ~ 125°C Analog Voltage SOT-23-3 Active ROHS3
LM62BIM3/NOPB Texas Instruments Analog, Local 0°C ~ 90°C Analog Voltage SOT-23-3 Obsolete ROHS3
LM62BIM3X/NOPB National Semiconductor Analog, Local 0°C ~ 90°C Analog Voltage SOT-23-3 Active Not specified
LM62CIM3X/NOPB Texas Instruments Analog, Local 0°C ~ 90°C Analog Voltage SOT-23-3 Active ROHS3
MCP9701T-E/TT Microchip Technology Analog, Local -10°C ~ 125°C Analog Voltage SOT-23-3 Active ROHS3
TC1047AVNBTR Microchip Technology Analog, Local -40°C ~ 125°C Analog Voltage SOT-23-3 Active ROHS3
TC1047VNBTR Microchip Technology Analog, Local -40°C ~ 125°C Analog Voltage SOT-23-3 Active ROHS3

Engineering Selection Recommendations

For Full Temperature Range Coverage (-55°C to 150°C): No direct substitute maintains the complete operating temperature range of the KTY82/121,235. The highest coverage available is -40°C to 125°C with DS60R+T&R, LM60QIM3/NOPB, LM60QIM3X/NOPB, TC1047AVNBTR, and TC1047VNBTR. Applications requiring operation below -40°C or above 125°C cannot be directly substituted with the listed parts.

For Active Product Status & Long-Term Availability: DS60R+T&R, LM60QIM3X/NOPB, LM62BIM3X/NOPB, LM62CIM3X/NOPB, MCP9701T-E/TT, TC1047AVNBTR, and TC1047VNBTR are all active products with current manufacturing support.

For ROHS3 Compliance: All substitute parts except LM62BIM3X/NOPB carry explicit ROHS3 certification, matching the original component's compliance status.

For Automotive Grade Applications: LM60QIM3/NOPB and LM60QIM3X/NOPB carry AEC-Q100 qualification, suitable for automotive temperature sensor applications.

Critical Design Consideration: The KTY82/121,235 is a resistance-based sensor requiring measurement circuitry to convert resistance to a usable signal. All listed substitutes are voltage-output analog sensors, requiring redesign of the signal conditioning circuit. This is a functional substitution, not a pin-compatible replacement.

Frequently Asked Questions (FAQ)

Q: Can I directly replace the KTY82/121,235 with any of these substitute parts without circuit modification?

A: No. The KTY82/121,235 outputs a resistance value, while all listed substitutes output an analog voltage. Your circuit must be redesigned to accept voltage input instead of measuring resistance. The SOT-23-3 package is mechanically compatible, but electrical interface changes are mandatory.

Q: Which substitute covers the widest temperature range?

A: DS60R+T&R, LM60QIM3/NOPB, LM60QIM3X/NOPB, TC1047AVNBTR, and TC1047VNBTR all operate from -40°C to 125°C. None reach the original -55°C lower limit. For applications requiring sub -40°C operation, no substitute from this list is suitable.

Q: What is the difference between LM60QIM3/NOPB and LM60QIM3X/NOPB?

A: Both are Texas Instruments analog temperature sensors with identical electrical specifications (-40°C to 125°C, 6.25mV/°C resolution, ±3°C accuracy). The primary difference is product status: LM60QIM3/NOPB is obsolete, while LM60QIM3X/NOPB is active. For new designs, LM60QIM3X/NOPB is recommended.

Q: Are all substitutes available in the same packaging?

A: Yes. All listed substitute parts use the TO-236-3 (SOT-23-3) surface mount package, ensuring mechanical compatibility with existing PCB layouts. Packaging format varies between Cut Tape (CT), Tape & Reel (TR), and Bulk, but the component package itself is identical.

Q: Which substitute has the best accuracy specification?

A: DS60R+T&R and TC1047AVNBTR both offer ±2°C accuracy at 25°C, matching the best available specifications in this list.

Q: Can I use LM62BIM3/NOPB or LM62CIM3X/NOPB if my application only operates between 0°C and 90°C?

A: Yes, if your application temperature range is strictly 0°C to 90°C, LM62BIM3/NOPB (obsolete) or LM62CIM3X/NOPB (active) are suitable. LM62CIM3X/NOPB is preferred due to active product status. These parts offer higher resolution (15.6mV/°C) compared to the -40°C to 125°C range sensors, providing better temperature discrimination in limited ranges.

Q: What does MSL Level 1 mean for these components?

A: MSL (Moisture Sensitivity Level) 1 indicates unlimited shelf life without moisture baking requirements. All listed parts carry MSL Level 1, meaning they can be stored indefinitely without special moisture control procedures before soldering.

Request Quote (Ships tomorrow)