Equivalent & Substitute Parts Reference: JCK1512D15

Part Overview

The XP Power JCK1512D15 is an active, isolated module DC-DC converter with dual outputs (+15V, -15V, each rated at 500mA) and a 15 W power rating, designed for ITE (commercial) applications. The module features OCP, SCP, and UVLO protections, ROHS3 compliance, and is supplied in a 5-DIP through-hole package. Alternative models may be required to address supply chain constraints, inventory requirements, or compliance needs, making the identification of equivalent models essential for uninterrupted production and design flexibility.

Substiute Parts

JCK1512D15
XP PowerIn Stock: 93114JCK1512D15 Datasheet
JCK1512D15
Current Part
DKA15A-15
MEAN WELL USA Inc.In Stock: 1326DKA15A-15 Datasheet
DKA15A-15
MFR Recommended

Key Parameters

Parameter Main Part (JCK1512D15)
Manufacturer XP Power
Type Isolated Module
Number of Outputs 2
Voltage - Input (Min) 9V
Voltage - Input (Max) 18V
Voltage - Output 1 15V
Voltage - Output 2 -15V
Current - Output (Max) 500mA, 500mA
Power (Watts) 15 W
Voltage - Isolation 1.5 kV
Efficiency 88%
Operating Temperature -40°C ~ 100°C
Mounting Type Through Hole
Package / Case 5-DIP Module
Size / Dimension 2.00" L x 1.00" W x 0.40" H
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
ECCN EAR99
HTSUS 8504.40.9580

Substitute Part Grouping Explanation

Substitute grouping is defined by matching the following permitted parameters: isolated module type, number of outputs (2), input voltage range (9V–18V), output voltages (+15V, -15V), output current (500mA per channel), power rating (15 W), mounting type (through hole), mechanical package (5-DIP Module), RoHS3 compliance, and commercial application suitability. Only parts strictly adhering to these specifications qualify as substitutes.

Parameter Comparison

Parameter Main Part (JCK1512D15) Substitute (DKA15A-15)
Manufacturer XP Power MEAN WELL USA Inc.
Type Isolated Module Isolated Module
Number of Outputs 2 2
Voltage - Input (Min) 9V 9V
Voltage - Input (Max) 18V 18V
Voltage - Output 1 15V 15V
Voltage - Output 2 -15V -15V
Current - Output (Max) 500mA, 500mA 500mA, 500mA
Power (Watts) 15 W 15 W
Voltage - Isolation 1.5 kV 1 kV
Efficiency 88% 83%
Operating Temperature -40°C ~ 100°C -40°C ~ 71°C (With Derating)
Mounting Type Through Hole Through Hole
Package / Case 5-DIP Module 5-DIP Module
Size / Dimension 2.00" L x 1.00" W x 0.40" H 2.00" L x 1.00" W x 0.44" H
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

Both JCK1512D15 and DKA15A-15 are designated as active products and comply with ROHS3 and ECCN EAR99 requirements. Moisture Sensitivity Level is rated 1 (unlimited) for both devices. Inventory status is favorable for immediate selection. Engineering selection based on documented compliance and status parameters is permissible.

Frequently Asked Questions (FAQ)

Q1: What determines direct substitute qualification for JCK1512D15? A1: Qualification requires matching type (isolated module), electrical parameters (input/output voltages and currents, power rating), mechanical package, mounting type, and compliance characteristics.

Q2: Are the packages for JCK1512D15 and DKA15A-15 identical for PCB design? A2: Both utilize a 5-DIP module through-hole package with similar dimensions, ensuring PCB and mechanical compatibility within allowed tolerances.

Q3: Does RoHS3 status affect substitution? A3: Both models are ROHS3 compliant, allowing selection within environments requiring hazardous substance restrictions.

Q4: Is operating temperature a strict substitution parameter? A4: Temperature rating is included in the substitution logic. Selection must be made within the specified ranges provided for each device.

Q5: Are output current and power ratings directly equivalent between both parts? A5: Both products specify dual outputs each rated at 500mA and a total power rating of 15 W.

Q6: How do isolation voltage and efficiency figures inform selection? A6: These are listed as part of the electrical parameters; however, only values explicitly provided are included in equivalence logic.

Request Quote (Ships tomorrow)