The JC030C-M by OmniOn Power is an isolated module DC-DC converter, providing 15V output at up to 2A (30W) with 18V–36V input range. Key features include remote on/off, overcurrent protection (OCP), and overvoltage protection (OVP), designed for ITE (Commercial) applications. The product is classified as obsolete, making identification of alternative models essential to ensure ongoing availability for replacement or new designs requiring compatible electrical and mechanical parameters.
Substiute Parts
Key Parameters
| Part Number | Series | Product Status | Type | Number of Outputs | Input Voltage (Min) | Input Voltage (Max) | Output Voltage 1 | Output Current (Max) | Power (Watts) | Isolation Voltage | Features | Efficiency | Operating Temperature | Mounting Type | Package / Case | Size / Dimension | Control Features | RoHS Status | REACH Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| JC030C-M | JC030 (30W) | Obsolete | Isolated Module | 1 | 18V | 36V | 15V | 2A | 30 W | 850 V | Remote On/Off, OCP, OVP | 83% | -40°C ~ 100°C | Through Hole | 9-DIP Module | 2.40" x 2.28" x 0.50" | Enable, Active High | RoHS non-compliant | REACH Unaffected |
Substitute Part Grouping Explanation
Substitution grouping is established strictly based on these electrical and mechanical parameters: number of outputs, input and output voltage ranges, output current, rated power, features, mounting type, package/case, isolation voltage, efficiency, operating temperature range, and compliance (RoHS/REACH status). Substitute parts must match or exceed these key parameters to ensure equivalent functionality and fit within the application.
Parameter Comparison
| Parameter | JC030C-M (OmniOn Power) | CCG30-24-15S (TDK-Lambda Americas Inc) |
|---|---|---|
| Product Status | Obsolete | Active |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Input Voltage (Min) | 18V | 9V |
| Input Voltage (Max) | 36V | 36V |
| Output Voltage 1 | 15V | 15V |
| Output Current (Max) | 2A | 2A |
| Power (Watts) | 30 W | 30 W |
| Isolation Voltage | 850 V | 1.5 kV |
| Features | Remote On/Off, OCP, OVP | Remote On/Off, OCP, OVP |
| Efficiency | 83% | 89% |
| Operating Temperature | -40°C ~ 100°C | -40°C ~ 85°C |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 9-DIP Module | 6-DIP Module |
| Size / Dimension | 2.40" x 2.28" x 0.50" | 1.00" x 1.00" x 0.39" |
| Control Features | Enable, Active High | Enable, Active Low |
| RoHS Status | RoHS non-compliant | RoHS Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
Engineering Selection Recommendations
Selection of CCG30-24-15S as a substitute for the JC030C-M is based on matching or exceeding key electrical and mechanical parameters including output voltage, output current, power rating, input voltage range, isolation voltage, and features. The JC030C-M is obsolete and RoHS non-compliant, while the CCG30-24-15S is active and RoHS compliant. Consider compliance status and product status for applications subject to ongoing availability and environmental regulations.
Frequently Asked Questions (FAQ)
Q1: What are the primary substitution criteria for DC-DC converter modules?
A1: Substitution requires matching output voltage, output current, power rating, input voltage, isolation voltage, module type, mounting type, and features, as well as consideration of compliance and product status.
Q2: Is pin compatibility guaranteed between JC030C-M and CCG30-24-15S?
A2: Mechanical differences in package/case and module size exist, with JC030C-M using a 9-DIP module and CCG30-24-15S a 6-DIP module. Exact pin compatibility is determined by the provided package/case information.
Q3: How does RoHS compliance affect selection?
A3: JC030C-M is RoHS non-compliant, while CCG30-24-15S is RoHS compliant. RoHS status is important for applications with environmental regulation requirements.
Q4: What is the significance of product status in selecting substitutes?
A4: JC030C-M is obsolete; CCG30-24-15S is active. Active status ensures ongoing availability for production and maintenance needs.
Q5: Are control features interchangeable between both parts?
A5: JC030C-M uses enable, active high control; CCG30-24-15S uses enable, active low control. This must be considered when integrating with existing system control logic.
Q6: Do the operating temperature ranges differ between these converters?
A6: JC030C-M operates from -40°C to 100°C; CCG30-24-15S operates from -40°C to 85°C. Selection must consider whether the substitute matches the required operating temperature range.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts