Equivalent & Substitute Parts Reference: JC030C-M

Part Overview

The JC030C-M by OmniOn Power is an isolated module DC-DC converter, providing 15V output at up to 2A (30W) with 18V–36V input range. Key features include remote on/off, overcurrent protection (OCP), and overvoltage protection (OVP), designed for ITE (Commercial) applications. The product is classified as obsolete, making identification of alternative models essential to ensure ongoing availability for replacement or new designs requiring compatible electrical and mechanical parameters.

Substiute Parts

JC030C-M
OmniOn PowerIn Stock: 7201JC030C-M Datasheet
JC030C-M
Current Part
CCG30-24-15S
TDK-Lambda Americas IncIn Stock: 961CCG30-24-15S Datasheet
CCG30-24-15S
Similar

Key Parameters

Part Number Series Product Status Type Number of Outputs Input Voltage (Min) Input Voltage (Max) Output Voltage 1 Output Current (Max) Power (Watts) Isolation Voltage Features Efficiency Operating Temperature Mounting Type Package / Case Size / Dimension Control Features RoHS Status REACH Status
JC030C-M JC030 (30W) Obsolete Isolated Module 1 18V 36V 15V 2A 30 W 850 V Remote On/Off, OCP, OVP 83% -40°C ~ 100°C Through Hole 9-DIP Module 2.40" x 2.28" x 0.50" Enable, Active High RoHS non-compliant REACH Unaffected

Substitute Part Grouping Explanation

Substitution grouping is established strictly based on these electrical and mechanical parameters: number of outputs, input and output voltage ranges, output current, rated power, features, mounting type, package/case, isolation voltage, efficiency, operating temperature range, and compliance (RoHS/REACH status). Substitute parts must match or exceed these key parameters to ensure equivalent functionality and fit within the application.

Parameter Comparison

Parameter JC030C-M (OmniOn Power) CCG30-24-15S (TDK-Lambda Americas Inc)
Product Status Obsolete Active
Type Isolated Module Isolated Module
Number of Outputs 1 1
Input Voltage (Min) 18V 9V
Input Voltage (Max) 36V 36V
Output Voltage 1 15V 15V
Output Current (Max) 2A 2A
Power (Watts) 30 W 30 W
Isolation Voltage 850 V 1.5 kV
Features Remote On/Off, OCP, OVP Remote On/Off, OCP, OVP
Efficiency 83% 89%
Operating Temperature -40°C ~ 100°C -40°C ~ 85°C
Mounting Type Through Hole Through Hole
Package / Case 9-DIP Module 6-DIP Module
Size / Dimension 2.40" x 2.28" x 0.50" 1.00" x 1.00" x 0.39"
Control Features Enable, Active High Enable, Active Low
RoHS Status RoHS non-compliant RoHS Compliant
REACH Status REACH Unaffected REACH Unaffected

Engineering Selection Recommendations

Selection of CCG30-24-15S as a substitute for the JC030C-M is based on matching or exceeding key electrical and mechanical parameters including output voltage, output current, power rating, input voltage range, isolation voltage, and features. The JC030C-M is obsolete and RoHS non-compliant, while the CCG30-24-15S is active and RoHS compliant. Consider compliance status and product status for applications subject to ongoing availability and environmental regulations.

Frequently Asked Questions (FAQ)

Q1: What are the primary substitution criteria for DC-DC converter modules?
A1: Substitution requires matching output voltage, output current, power rating, input voltage, isolation voltage, module type, mounting type, and features, as well as consideration of compliance and product status.

Q2: Is pin compatibility guaranteed between JC030C-M and CCG30-24-15S?
A2: Mechanical differences in package/case and module size exist, with JC030C-M using a 9-DIP module and CCG30-24-15S a 6-DIP module. Exact pin compatibility is determined by the provided package/case information.

Q3: How does RoHS compliance affect selection?
A3: JC030C-M is RoHS non-compliant, while CCG30-24-15S is RoHS compliant. RoHS status is important for applications with environmental regulation requirements.

Q4: What is the significance of product status in selecting substitutes?
A4: JC030C-M is obsolete; CCG30-24-15S is active. Active status ensures ongoing availability for production and maintenance needs.

Q5: Are control features interchangeable between both parts?
A5: JC030C-M uses enable, active high control; CCG30-24-15S uses enable, active low control. This must be considered when integrating with existing system control logic.

Q6: Do the operating temperature ranges differ between these converters?
A6: JC030C-M operates from -40°C to 100°C; CCG30-24-15S operates from -40°C to 85°C. Selection must consider whether the substitute matches the required operating temperature range.