The IXGP30N60C2 is an IGBT (Insulated Gate Bipolar Transistor) rated for 600V collector-emitter breakdown voltage with a maximum collector current of 70A and 190W power dissipation. This device is packaged in a TO-220-3 through-hole configuration and belongs to the HiPerFAST™ series from IXYS.
The IXGP30N60C2 is classified as obsolete. Identifying equivalent and substitute parts is necessary to maintain design continuity, ensure supply chain availability, and support ongoing production requirements for applications currently utilizing this component.
Substiute Parts
Key Parameters
| Parameter | Value | Unit |
|---|---|---|
| Voltage - Collector Emitter Breakdown (Max) | 600 | V |
| Current - Collector (Ic) (Max) | 70 | A |
| Current - Collector Pulsed (Icm) | 150 | A |
| Power - Max | 190 | W |
| Vce(on) (Max) @ Vge, Ic | 2.7V @ 15V, 24A | V |
| Gate Charge | 70 | nC |
| Switching Energy (off) | 190 | µJ |
| Td (on/off) @ 25°C | 13ns/70ns | ns |
| Operating Temperature Range | -55 to 150 | °C (TJ) |
| Package / Case | TO-220-3 | — |
| Mounting Type | Through Hole | — |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | — |
Substitute Part Grouping Explanation
Substitution of the IXGP30N60C2 is determined by compatibility across the following critical parameters:
Package and Mounting Compatibility: The substitute part must use the TO-220-3 through-hole package to ensure mechanical and thermal interface compatibility with existing PCB designs and heat sink mounting arrangements.
Electrical Performance Envelope: The substitute part must support the voltage and current requirements of the application. While the IXGP30N60C2 operates at 600V maximum, a substitute with higher voltage rating (such as 1200V) remains compatible for 600V applications, as the device operates within its safe operating area. The collector current rating must equal or exceed 70A to handle the specified load.
Thermal and Switching Characteristics: Gate charge, switching delay times, and on-state voltage drop influence circuit performance and thermal management. Substitutes with comparable or improved characteristics maintain functional equivalence.
Compliance and Availability: The substitute part must have an active product status to ensure ongoing supply chain availability and support. Compliance certifications (RoHS, REACH) confirm suitability for current manufacturing standards.
Parameter Comparison
| Parameter | IXGP30N60C2 | IXYP30N120C3 | Unit |
|---|---|---|---|
| Manufacturer | IXYS | IXYS | — |
| Category | Transistors, IGBTs | Transistors, IGBTs | — |
| Voltage - Collector Emitter Breakdown (Max) | 600 | 1200 | V |
| Current - Collector (Ic) (Max) | 70 | 75 | A |
| Current - Collector Pulsed (Icm) | 150 | 145 | A |
| Power - Max | 190 | 500 | W |
| Vce(on) (Max) @ Vge, Ic | 2.7V @ 15V, 24A | 3.3V @ 15V, 30A | V |
| Gate Charge | 70 | 69 | nC |
| Td (on/off) @ 25°C | 13ns/70ns | 19ns/130ns | ns |
| Operating Temperature Range | -55 to 150 | -55 to 175 | °C (TJ) |
| Package / Case | TO-220-3 | TO-220-3 | — |
| Mounting Type | Through Hole | Through Hole | — |
| Product Status | Obsolete | Active | — |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) | — |
| REACH Status | REACH Unaffected | REACH Unaffected | — |
| ECCN | EAR99 | EAR99 | — |
Engineering Selection Recommendations
The IXYP30N120C3 is a direct substitute for the obsolete IXGP30N60C2 based on the following engineering criteria:
Package Compatibility: Both devices use the TO-220-3 through-hole package, ensuring identical PCB footprint and thermal interface compatibility without design modification.
Electrical Compatibility: The IXYP30N120C3 exceeds the electrical requirements of the IXGP30N60C2. With a 1200V rating versus 600V, the substitute operates safely within the application voltage envelope. The collector current rating of 75A exceeds the 70A requirement. The higher power rating (500W versus 190W) provides additional thermal margin.
Product Status and Supply: The IXYP30N120C3 carries an active product status, ensuring long-term availability and manufacturing support. The IXGP30N60C2 is obsolete, making the substitute necessary for continued production.
Compliance: Both devices maintain identical REACH and ECCN classifications (REACH Unaffected, EAR99), confirming regulatory equivalence. The IXYP30N120C3 includes RoHS3 compliance certification, meeting current manufacturing standards.
Thermal Performance: The IXYP30N120C3 supports an extended operating temperature range (-55°C to 175°C versus -55°C to 150°C), providing additional thermal headroom for demanding applications.
Frequently Asked Questions (FAQ)
Q: Can the IXYP30N120C3 directly replace the IXGP30N60C2 without circuit modification?
A: Yes. Both devices share the TO-220-3 package and standard input type. The IXYP30N120C3 meets or exceeds all electrical parameters of the IXGP30N60C2 within the application's operating envelope. No PCB layout changes are required.
Q: What is the impact of the higher voltage rating (1200V versus 600V) on circuit operation?
A: The higher voltage rating does not negatively impact circuit operation. The IXYP30N120C3 operates safely at 600V and below. The higher rating provides additional voltage margin and protection against transient overvoltage conditions.
Q: How do the switching characteristics differ between these devices?
A: The IXYP30N120C3 exhibits slightly longer switching delay times (19ns on versus 13ns on; 130ns off versus 70ns off). Gate charge is comparable (69nC versus 70nC). These differences are within typical circuit tolerance and do not require gate drive circuit redesign for standard applications.
Q: Are there thermal management differences?
A: The IXYP30N120C3 has a higher power rating (500W versus 190W) and supports a higher maximum junction temperature (175°C versus 150°C). These characteristics improve thermal performance and provide additional design margin for heat dissipation.
Q: What is the significance of the on-state voltage difference (3.3V versus 2.7V)?
A: The on-state voltage is measured at different test conditions (IXYP30N120C3 at 30A versus IXGP30N60C2 at 24A). At equivalent current levels, the voltage drop difference is minimal and does not require circuit redesign. The higher power rating of the substitute accommodates any minor increase in conduction losses.
Q: Are moisture sensitivity and compliance ratings identical?
A: Yes. Both devices carry MSL 1 (Unlimited), REACH Unaffected, and EAR99 classifications. The IXYP30N120C3 additionally carries RoHS3 compliance, confirming suitability for current manufacturing standards.
Q: Is the TO-220-3 package identical for both devices?
A: Yes. Both devices use the TO-220-3 through-hole package with identical pin configuration and thermal interface. Existing heat sink mounting and PCB layouts require no modification.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts