IUG6-1-61-30.0-01 Equivalent & Substitute Parts

Part Overview

The IUG6-1-61-30.0-01 is a single-pole circuit breaker with magnetic hydraulic delay protection manufactured by Sensata-Airpax. This component is rated for 20A at 250V AC and 80V DC, featuring a lever-actuated panel mount design. The product is active and RoHS compliant with MSL 1 rating. Equivalent substitute parts are necessary when the primary part number becomes unavailable or when procurement from alternative Sensata-Airpax series offers inventory advantages.

Substiute Parts

IUG6-1-61-30.0-01
Sensata-AirpaxIn Stock: 1150IUG6-1-61-30.0-01 Datasheet
IUG6-1-61-30.0-01
Current Part
IEG1-1-63-20.0-01-V
Sensata-AirpaxIn Stock: 1152IEG1-1-63-20.0-01-V Datasheet
IEG1-1-63-20.0-01-V
Parametric Equivalent
IEL1-1-51-20.0-01-V
Sensata-AirpaxIn Stock: 968IEL1-1-51-20.0-01-V Datasheet
IEL1-1-51-20.0-01-V
Parametric Equivalent
IELK1-1-72-20.0-01-V
Sensata-AirpaxIn Stock: 1256IELK1-1-72-20.0-01-V Datasheet
IELK1-1-72-20.0-01-V
Parametric Equivalent
IEG6-1-72-20.0-01-V
Sensata-AirpaxIn Stock: 1099IEG6-1-72-20.0-01-V Datasheet
IEG6-1-72-20.0-01-V
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Sensata-Airpax
Breaker Type Magnetic (Hydraulic Delay)
Current Rating 20A
Voltage Rating - AC 250V
Voltage Rating - DC 80V
Mounting Type Panel Mount
Actuator Type Lever
Number of Poles 1
RoHS Status RoHS Compliant
MSL Rating 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution eligibility for the IUG6-1-61-30.0-01 is determined by strict equivalence across the following parameters: breaker type (magnetic hydraulic delay), current rating (20A), AC voltage rating (250V), DC voltage rating (80V), mounting configuration (panel mount), actuator mechanism (lever), pole count (1), and manufacturer (Sensata-Airpax). All listed substitute parts meet these criteria. Differences in series designation (IUG, IEG, IEL, IELK) and base product numbers reflect internal Sensata-Airpax product line organization and do not affect electrical or mechanical compatibility. Packaging variations (bulk vs. standard) and approval agency certifications are secondary considerations that do not preclude substitution.

Parameter Comparison

Part Number Series Current Rating Voltage AC Voltage DC Breaker Type Mounting Poles Actuator RoHS Inventory (Pcs)
IUG6-1-61-30.0-01 IUG 20A 250V 80V Magnetic (Hydraulic Delay) Panel Mount 1 Lever Compliant 1065
IEG1-1-63-20.0-01-V IEG 20A 250V 80V Magnetic (Hydraulic Delay) Panel Mount 1 Lever Compliant 1051
IEL1-1-51-20.0-01-V IEL 20A 250V 80V Magnetic (Hydraulic Delay) Panel Mount 1 Lever Compliant 919
IELK1-1-72-20.0-01-V IEL 20A 250V 80V Magnetic (Hydraulic Delay) Panel Mount 1 Lever Compliant 1212
IEG6-1-72-20.0-01-V IEG 20A 250V 80V Magnetic (Hydraulic Delay) Panel Mount 1 Lever Compliant 1032

Engineering Selection Recommendations

All substitute parts listed are active products with RoHS compliance and MSL 1 rating, matching the primary part specification. Selection among equivalents may be based on inventory availability and approval agency certifications. The IEG1-1-63-20.0-01-V and IEG6-1-72-20.0-01-V carry CSA, TUV, and UL1077 certifications. The IELK1-1-72-20.0-01-V carries UL1077 certification. The IEL1-1-51-20.0-01-V carries no additional certifications beyond RoHS compliance. Selection should align with application-specific regulatory requirements.

Frequently Asked Questions (FAQ)

Q: Can IEG1-1-63-20.0-01-V be used as a direct replacement for IUG6-1-61-30.0-01?

A: Yes. Both parts share identical electrical ratings (20A, 250V AC, 80V DC), breaker type (magnetic hydraulic delay), mounting configuration (panel mount), and mechanical interface (single-pole lever actuator). Series designation differences do not affect functional compatibility.

Q: What is the difference between bulk and standard packaging for these circuit breakers?

A: Packaging designation reflects order quantity and presentation format. Bulk packaging typically accommodates larger order quantities. Electrical and mechanical specifications remain unchanged regardless of packaging type.

Q: Do approval agency certifications affect substitution eligibility?

A: Certifications (CSA, TUV, UL1077) are application-dependent. All listed parts are RoHS compliant and MSL 1 rated. Selection of a part with specific certifications should be based on end-application regulatory requirements, not substitution compatibility.

Q: Are there any mechanical differences between IUG, IEG, IEL, and IELK series breakers?

A: Series designations reflect Sensata-Airpax product line organization. All listed parts meet identical mechanical specifications for panel mount installation and lever actuation. No mechanical incompatibility exists between series.

Q: What inventory levels should influence part selection?

A: Inventory quantities are provided for procurement planning. IELK1-1-72-20.0-01-V has the highest stock (1212 Pcs), while IEL1-1-51-20.0-01-V has the lowest (919 Pcs). Selection should prioritize application requirements and certifications over inventory levels.