ITV1212S Equivalent & Substitute Parts Reference

Part Overview

ITV1212S is an isolated DC-DC converter manufactured by XP Power, featuring dual outputs of +12V and -12V with a maximum output current of 41.6mA per channel and a rated power of 1W. The device supports a wide operating temperature range and is designed for ITE (Commercial) applications. As the product status is Active with available inventory, finding alternative models is applicable for design redundancy, sourcing flexibility, or cross-referencing. Alternative or equivalent models must match its key electrical, mechanical, and compliance attributes.

Substiute Parts

ITV1212S
XP PowerIn Stock: 1168ITV1212S Datasheet
ITV1212S
Current Part
CRV1D1212SC
Murata Power Solutions Inc.In Stock: 840CRV1D1212SC Datasheet
CRV1D1212SC
Direct
RH-1212D
Recom PowerIn Stock: 12298RH-1212D Datasheet
RH-1212D
Direct

Key Parameters

ParameterITV1212S
ManufacturerXP Power
TypeIsolated Module
Number of Outputs2
Voltage - Input (Min)10.8V
Voltage - Input (Max)13.2V
Voltage - Output 112V
Voltage - Output 2-12V
Current - Output (Max)41.6mA, 41.6mA
Power (Watts)1W
Voltage - Isolation3kV
ApplicationsITE (Commercial)
Mounting TypeThrough Hole
Package / Case7-SIP Module, 5 Leads
Size / Dimension0.77" L x 0.24" W x 0.39" H
Operating Temperature-40°C ~ 105°C
Efficiency80%
RoHS StatusROHS3 Compliant
Product StatusActive
Moisture Sensitivity Level (MSL)1 (Unlimited)
ECCNEAR99
HTSUS8504.40.9580

Substitute Part Grouping Explanation

Substitution is strictly determined by direct parameter equivalency between the main part and alternatives. For isolated DC-DC converters, the decisive criteria are input voltage range, output voltages and currents, isolation voltage, power rating, mounting type, package dimensions, package configuration, operating temperature, and compliance certifications. All listed substitutes match the permitted ranges, voltages, currents, isolation, and form factors specified, meeting ROHS3 compliance and active product status.

Parameter Comparison

Parameter ITV1212S
(XP Power)
CRV1D1212SC
(Murata Power Solutions Inc.)
RH-1212D
(Recom Power)
Type Isolated Module Isolated Module Isolated Module
Number of Outputs 2 2 2
Voltage - Input (Min) 10.8V 10.8V 10.8V
Voltage - Input (Max) 13.2V 13.2V 13.2V
Voltage - Output 1 12V 12V 12V
Voltage - Output 2 -12V -12V -12V
Current - Output (Max) 41.6mA, 41.6mA 42mA, 42mA 42mA, 42mA
Power (Watts) 1W 1W 1W
Voltage - Isolation 3kV 3kV 3kV
Applications ITE (Commercial) ITE (Commercial) ITE (Commercial), Medical
Mounting Type Through Hole Through Hole Through Hole
Package / Case 7-SIP Module, 5 Leads 7-SIP Module, 5 Leads 7-SIP Module, 5 Leads
Size / Dimension 0.77" L x 0.24" W x 0.39" H 0.77" L x 0.24" W x 0.39" H 0.77" L x 0.24" W x 0.40" H
Operating Temperature -40°C ~ 105°C -40°C ~ 85°C -40°C ~ 90°C
Efficiency 80% 81% 84%
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
Product Status Active Active Active
Moisture Sensitivity Level (MSL) 1 (Unlimited) Not Applicable 1 (Unlimited)
ECCN EAR99 EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

All listed parts—ITV1212S, CRV1D1212SC, and RH-1212D—maintain Active status, match key compliance requirements including ROHS3, and carry ECCN EAR99 designation. Moisture Sensitivity Level for RH-1212D and ITV1212S is 1 (Unlimited); CRV1D1212SC is Not Applicable. All options are suitable for selection where compliance and inventory availability are critical considerations.

Frequently Asked Questions (FAQ)

Q1: What electrical parameters must be identical for direct substitution in this DC-DC converter category?
A1: Input voltage range, output voltages, output current ratings, power rating, isolation voltage, and efficiency must match the required specifications for compatible substitution.

Q2: Are the listed substitute models compatible in terms of mounting and package size?
A2: All models use the 7-SIP Module, 5 Leads package with dimensions compatible for footprint and placement in through-hole PCB layouts.

Q3: Do differences in operating temperature affect substitution?
A3: Substitute products provide different upper operating temperature limits; selection should match application requirements. All substitutes meet at least -40°C on the lower end.

Q4: Are all substitute parts compliant with ROHS3 and relevant certification?
A4: All listed parts are ROHS3 compliant and are classified as EAR99 for ECCN, ensuring regulatory conformity.

Q5: Is the moisture sensitivity level comparable across substitutes?
A5: ITV1212S and RH-1212D have MSL 1 (Unlimited), while CRV1D1212SC is Not Applicable for MSL. For typical storage and handling, these designations support standard assembly procedures.

Q6: Are there application-specific features or approvals in the listed substitutes?
A6: All substitutes are designated for ITE (Commercial). RH-1212D additionally lists Medical applications as permitted.

Q7: What package details must be matched for direct substitution?
A7: The substitute must have the same mounting type (Through Hole) and package dimensions compatible with the original (7-SIP Module, 5 Leads, ~0.77" x 0.24" x 0.39"-0.40" H).

Request Quote (Ships tomorrow)