Request Quote
(Ships tomorrow)
ISP1215 Equivalent & Substitute Parts Reference
Part Overview
The ISP1215 from XP Power is an isolated module DC-DC converter providing dual outputs of +15V and -15V at up to 67mA per output, with a 2W power rating. It offers 1.5 kV isolation, is intended for ITE (Commercial) applications, and features SCP (short circuit protection). The device is ROHS3 compliant and available in a 16-SMD Module, 6 Leads package. It is now classified as obsolete, requiring identification of direct substitutes to support ongoing design, maintenance, and manufacturing programs.
Substiute Parts
Key Parameters
| Parameter | ISP1215 |
|---|---|
| Type | Isolated Module |
| Number of Outputs | 2 |
| Voltage - Input (Min) | 9V |
| Voltage - Input (Max) | 18V |
| Voltage - Output 1 | 15V |
| Voltage - Output 2 | -15V |
| Current - Output (Max) | 67mA |
| Power (Watts) | 2 W |
| Voltage - Isolation | 1.5 kV |
| Applications | ITE (Commercial) |
| Features | SCP |
| Operating Temperature | -40°C ~ 85°C |
| Efficiency | 80% |
| Mounting Type | Surface Mount |
| Package / Case | 16-SMD Module, 6 Leads |
| Size / Dimension | 0.94" L x 0.54" W x 0.31" H (23.9mm x 13.7mm x 8.0mm) |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitute DC-DC converter modules must match the following parameters: isolated design, dual outputs of +15V and -15V, input voltage range encompassing at least 9V to 18V, per-output current capability of at least 67mA, minimum isolation voltage of 1.5 kV, mounting style as Surface Mount, similar package dimensions, ITE (Commercial) application rating, and RoHS compliance. Substitute devices must also operate across the same temperature range and provide equivalent or better protective features such as SCP.
Parameter Comparison
| Parameter | ISP1215 (XP Power) |
ATA00CC18S-L (ARTESYN) |
|---|---|---|
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 2 | 2 |
| Voltage - Input (Min) | 9V | 9V |
| Voltage - Input (Max) | 18V | 36V |
| Voltage - Output 1 | 15V | 15V |
| Voltage - Output 2 | -15V | -15V |
| Current - Output (Max) | 67mA | 100mA, 100mA |
| Power (Watts) | 2 W | 3 W |
| Voltage - Isolation | 1.5 kV | 1.5 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | SCP | Remote On/Off, OCP, SCP |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Efficiency | 80% | 80% |
| Mounting Type | Surface Mount | Surface Mount |
| Package / Case | 16-SMD Module, 6 Leads | 16-SMD Module, 7 Leads |
| Size / Dimension | 0.94" L x 0.54" W x 0.31" H (23.9mm x 13.7mm x 8.0mm) | 0.94" L x 0.54" W x 0.31" H (23.9mm x 13.7mm x 8.0mm) |
| RoHS Status | ROHS3 Compliant | RoHS Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 2 (1 Year) |
| Product Status | Obsolete | Active |
Engineering Selection Recommendations
Selection of substitute DC-DC converter modules for ISP1215 should be based on direct parameter equivalence, current availability, and product compliance. When the main part is obsolete, use parts that match electrical performance, mechanical footprint, RoHS status, and application certifications. The ATA00CC18S-L is active and meets ROHS requirements.
Frequently Asked Questions (FAQ)
Q: What criteria determine whether a DC-DC converter module is a suitable substitute for the ISP1215?
A: Suitable substitutes must provide isolated dual outputs of +15V and -15V, support an input range from 9V to at least 18V, match or exceed the maximum output current and power, maintain 1.5 kV isolation, provide surface mount installation in a package with similar dimensions, and hold equivalent compliance and application ratings.
Q: Is the lead configuration compatible between ISP1215 and ATA00CC18S-L?
A: Both modules share the 16-SMD form factor, with ISP1215 having 6 leads and ATA00CC18S-L featuring 7 leads. Comparison of pin assignments should be made with product datasheets for mechanical layout evaluation.
Q: Are there any differences in moisture sensitivity level (MSL) impacting reflow soldering processes?
A: ISP1215 has MSL 1 (unlimited floor life), while ATA00CC18S-L has MSL 2 (one year floor life). This impacts storage and handling procedures before PCB assembly.
Q: Do both modules conform to RoHS environmental standards?
A: ISP1215 is ROHS3 compliant, and ATA00CC18S-L is RoHS compliant.
Q: Are there changes required in application conditions when shifting from ISP1215 to ATA00CC18S-L?
A: Both modules support ITE (Commercial) applications, operate at the same temperature range, and deliver equivalent functional protection, such as SCP (short circuit protection).
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts