ISP1205 Equivalent & Substitute Parts Reference

Part Overview

The ISP1205 (XP Power) is an isolated module DC-DC converter featuring dual outputs of +5V and -5V at 200mA, designed for ITE (Commercial) applications. The device provides a maximum output power of 2W, operates from a 9V to 18V input, and is housed in a 16-SMD surface mount package. With a part status of "Obsolete," sourcing direct replacements is required to ensure ongoing designs or maintenance can be fulfilled without interruption.

Substiute Parts

ISP1205
XP PowerIn Stock: 1097ISP1205 Datasheet
ISP1205
Current Part
ISX0624D05
XP PowerIn Stock: 1058ISX0624D05 Datasheet
ISX0624D05
MFR Recommended

Key Parameters

Manufacturer Part Number Manufacturer Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Voltage - Output 2 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Moisture Sensitivity Level (MSL) ECCN HTSUS Part Status
ISP1205 XP Power Isolated Module 2 9V 18V 5V -5V 200mA 2W 1.5kV ITE (Commercial) SCP -40°C ~ 85°C 74% Surface Mount 16-SMD Module, 6 Leads 0.94" x 0.54" x 0.31" ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9580 Obsolete

Substitute Part Grouping Explanation

Substitution is determined strictly by matching electrical and mechanical key parameters: type, output configuration, input voltage range, output voltages, maximum output current, maximum power, isolation voltage, mounting type, package style, operating temperature, RoHS compliance, and MSL rating. Only parts meeting all application-critical specifications (as listed above) are included as substitutes.

Parameter Comparison

Manufacturer Part Number Manufacturer Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Voltage - Output 2 Power (Watts) Voltage - Isolation Applications Mounting Type Package / Case Operating Temperature RoHS Status Moisture Sensitivity Level (MSL) ECCN HTSUS Part Status
ISP1205 XP Power Isolated Module 2 9V 18V 5V -5V 2W 1.5kV ITE (Commercial) Surface Mount 16-SMD Module, 6 Leads -40°C ~ 85°C ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9580 Obsolete
ISX0624D05 XP Power Isolated Module 2 9V 36V 5V -5V 6W 1.5kV ITE (Commercial) Surface Mount 16-SMD Module, 7 Leads -40°C ~ 100°C ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9580 Active

Engineering Selection Recommendations

ISX0624D05 is ROHS3 compliant and has a Moisture Sensitivity Level (MSL) of 1 (Unlimited), matching the compliance and handling requirements of ISP1205. Both parts have ECCN EAR99 and HTSUS 8504.40.9580 regulatory status. ISX0624D05 is listed as "Active," making it suitable for immediate use as a substitute for the obsolete ISP1205.

Frequently Asked Questions (FAQ)

Q: What criteria determine if ISX0624D05 can be substituted for ISP1205?
A: Substitution is defined by matching output voltages, output channels, input voltage range, isolation rating, mounting type, package, regulatory status, RoHS compliance, and MSL.

Q: Are the package and mounting style compatible?
A: Both ISP1205 and ISX0624D05 use surface mount technology in a 16-SMD module format. Lead count should be verified based on layout compatibility.

Q: Is the input and output voltage specification suitable for direct replacement?
A: ISX0624D05 supports 9V to 36V input, compared to ISP1205's 9V to 18V, and matches both +5V and -5V outputs.

Q: Are there differences in operating temperature range or power handling?
A: ISX0624D05 offers a wider operating temperature range and higher power capacity. Selection must be based strictly on application power and temperature requirements as provided.

Q: How do compliance and regulatory statuses align?
A: Both parts are ROHS3 compliant, MSL 1 (Unlimited), ECCN EAR99, and HTSUS 8504.40.9580, supporting direct substitution for regulatory and inventory purposes.

Request Quote (Ships tomorrow)