Equivalent & Substitute Parts Reference for ISH2415A-TR

Part Overview

The ISH2415A-TR by XP Power is an isolated DC-DC converter module featuring a single 15V output at 133mA, designed for commercial ITE applications. This part is classified as obsolete, requiring electronic engineers to select compatible substitute DC-DC converter models to support ongoing designs, maintenance, and procurement. Substitute selection must be based solely on provided electrical and mechanical parameters.

Substiute Parts

ISH2415A-TR
XP PowerIn Stock: 1514ISH2415A-TR Datasheet
ISH2415A-TR
Current Part
PDS2-S24-S15-M-TR
CUI Inc.In Stock: 1040PDS2-S24-S15-M-TR Datasheet
PDS2-S24-S15-M-TR
Direct
PDS2-S24-S15-M-TR
CUI Inc.In Stock: 1040PDS2-S24-S15-M-TR Datasheet
PDS2-S24-S15-M-TR
Direct

Key Parameters

ParameterISH2415A-TR
ManufacturerXP Power
Product StatusObsolete
TypeIsolated Module
Number of Outputs1
Input Voltage Range21.6V ~ 26.4V
Output Voltage15V
Output Current (Max)133mA
Power (Watts)2 W
Voltage Isolation1.5 kV
ApplicationsITE (Commercial)
FeaturesSCP
Operating Temperature-40°C ~ 105°C
Efficiency83%
Mounting TypeSurface Mount
Package / Case8-SMD Module, 5 Leads
Size / Dimension0.50" L x 0.44" W x 0.29" H (12.7mm x 11.2mm x 7.3mm)
RoHS StatusROHS3 Compliant
MSL1 (Unlimited)

Substitute Part Grouping Explanation

Substitute grouping is based strictly on these electrical and mechanical compatibility criteria:

  • Isolated module DC-DC converter topology
  • One output channel
  • Input voltage range: 21.6V to 26.4V
  • Output voltage: 15V
  • Maximum output current: 133mA
  • Maximum output power: 2 W
  • Isolation rating: 1.5 kV
  • Surface mount package: 8-SMD Module, 5 Leads
  • ITE (Commercial) applications
  • Efficiency: 83%
  • Operating temperature: -40°C ~ 105°C
  • Features: SCP (Short Circuit Protection)
  • Compliance: RoHS, appropriate moisture sensitivity level (MSL)

Only substitute models matching these parameters as provided can be listed as equivalents.

Parameter Comparison

Parameter ISH2415A-TR PDS2-S24-S15-M-TR
ManufacturerXP PowerCUI Inc.
Product StatusObsoleteActive
TypeIsolated ModuleIsolated Module
Number of Outputs11
Voltage - Input (Min)21.6V21.6V
Voltage - Input (Max)26.4V26.4V
Voltage - Output 115V15V
Current - Output (Max)133mA133mA
Power (Watts)2 W2 W
Voltage - Isolation1.5 kV1.5 kV
ApplicationsITE (Commercial)ITE (Commercial)
FeaturesSCPSCP
Operating Temperature-40°C ~ 105°C-40°C ~ 105°C (With Derating)
Efficiency83%83%
Mounting TypeSurface MountSurface Mount
Package / Case8-SMD Module, 5 Leads8-SMD Module, 5 Leads
Size / Dimension0.50" L x 0.44" W x 0.29" H0.50" L x 0.33" W x 0.29" H
RoHS StatusROHS3 CompliantRoHS Compliant
MSL1 (Unlimited)1 (Unlimited)

Engineering Selection Recommendations

Selection of substitute parts is dictated exclusively by product status and compliance certifications. The main part ISH2415A-TR is obsolete, necessitating use of alternate models with equivalent electrical and mechanical parameters and current regulatory status. PDS2-S24-S15-M-TR is RoHS compliant and has MSL 1 (Unlimited), matching environmental and handling profiles. Approvals for ITE (Commercial) applications must be verified according to specified standards. Use only substitute parts listed with the corresponding certifications and regulatory statuses provided.

Frequently Asked Questions (FAQ)

Q: What parameters must match for substituting ISH2415A-TR?
A: Substitute DC-DC converter modules must match input voltage range, output voltage and current, isolation rating, package type, efficiency, and compliance parameters exactly as listed.

Q: Is the PDS2-S24-S15-M-TR form-factor compatible with ISH2415A-TR?
A: Both models utilize an 8-SMD Module, 5 Leads surface mount package; minor variations in width do not alter lead configuration compatibility.

Q: Does the substitute part provide the same isolation and protection features?
A: Both ISH2415A-TR and its substitute, PDS2-S24-S15-M-TR, offer 1.5 kV isolation and Short Circuit Protection (SCP).

Q: Are compliance and environmental criteria equivalent?
A: Both parts are supplied as RoHS compliant with MSL 1 (Unlimited), suitable for extended storage and industry-standard environmental handling.

Q: Are the substitute operating conditions and efficiency the same?
A: Both parts specify -40°C to 105°C operating temperature and 83% efficiency based on provided parameters.

Q: Can the substitute part be used in commercial ITE applications?
A: The substitute shares the same application category (ITE, Commercial) as the main part according to supplied descriptions.

Request Quote (Ships tomorrow)