ISH2412A-TR Equivalent & Substitute Parts Reference

Part Overview

The ISH2412A-TR from XP Power is an obsolete isolated DC-DC converter module delivering 12V at 167mA from a 21.6V–26.4V input, with 2W rated output, surface-mount 8-SMD package, and integrated short-circuit protection. Due to its obsolete status and critical role in commercial ITE applications, identifying direct alternatives with matching or superior electrical, mechanical, and regulatory performance is necessary for continued system compatibility and compliance.

Substiute Parts

ISH2412A-TR
XP PowerIn Stock: 1230ISH2412A-TR Datasheet
ISH2412A-TR
Current Part
PDS2-S24-S12-M-TR
CUI Inc.In Stock: 2229PDS2-S24-S12-M-TR Datasheet
PDS2-S24-S12-M-TR
Direct
PDSE2-S24-S12-M-TR
CUI Inc.In Stock: 1348PDSE2-S24-S12-M-TR Datasheet
PDSE2-S24-S12-M-TR
Similar
PDS2-S24-S12-M-TR
CUI Inc.In Stock: 2229PDS2-S24-S12-M-TR Datasheet
PDS2-S24-S12-M-TR
Direct
PDSE2-S24-S12-M-TR
CUI Inc.In Stock: 1348PDSE2-S24-S12-M-TR Datasheet
PDSE2-S24-S12-M-TR
Similar

Key Parameters

ParameterISH2412A-TR
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)21.6V
Voltage - Input (Max)26.4V
Voltage - Output 112V
Current - Output (Max)167mA
Power (Watts)2 W
Voltage - Isolation1.5 kV
ApplicationsITE (Commercial)
FeaturesSCP
Operating Temperature-40°C ~ 105°C
Efficiency82%
Mounting TypeSurface Mount
Package / Case8-SMD Module, 5 Leads
Size / Dimension0.50" L x 0.44" W x 0.29" H
RoHS StatusROHS3 Compliant
MSL1 (Unlimited)

Substitute Part Grouping Explanation

Substitution is strictly determined by matching the following key parameters:

  • Type: Isolated Module
  • Number of Outputs: 1
  • Input Voltage Range: 21.6V–26.4V
  • Output Voltage: 12V
  • Output Current: 167mA
  • Output Power: 2 W
  • Isolation Voltage: 1.5 kV
  • Application: ITE (Commercial)
  • Features: At least SCP (Short-Circuit Protection) or Adjustable Output
  • Operating Temperature: -40°C ~ 105°C (with potential derating)
  • Mounting: Surface Mount, Package: 8-SMD Module, 5 Leads
  • Size/Footprint compatibility
  • RoHS and MSL status

Parameter Comparison

Parameter ISH2412A-TR PDS2-S24-S12-M-TR PDSE2-S24-S12-M-TR
Manufacturer XP Power CUI Inc. CUI Inc.
Status Obsolete Active Active
Type Isolated Module Isolated Module Isolated Module
Number of Outputs 1 1 1
Input Voltage (Min) 21.6V 21.6V 21.6V
Input Voltage (Max) 26.4V 26.4V 26.4V
Output Voltage 1 12V 12V 12V
Output Current (Max) 167mA 167mA 167mA
Power (Watts) 2 W 2 W 2.004 W
Voltage - Isolation 1.5 kV 1.5 kV 1.5 kV
Applications ITE (Commercial) ITE (Commercial) ITE (Commercial)
Features SCP SCP Adjustable Output
Operating Temperature Range -40°C ~ 105°C -40°C ~ 105°C (With Derating) -40°C ~ 105°C (With Derating)
Efficiency 82% 82% 84%
Mounting Type Surface Mount Surface Mount Surface Mount
Package / Case 8-SMD Module, 5 Leads 8-SMD Module, 5 Leads 8-SMD Module, 5 Leads
Size / Dimension 0.50" x 0.44" x 0.29" 0.50" x 0.33" x 0.29" 0.52" x 0.33" x 0.29"
RoHS Status ROHS3 Compliant RoHS Compliant ROHS3 Compliant
MSL 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

Substitute selection is guided by product status, RoHS compliance, and MSL equivalency. Only parts with identical or better compliance and remaining active status are included. Substitute parts PDS2-S24-S12-M-TR and PDSE2-S24-S12-M-TR are RoHS compliant, share the same MSL rating, and are active products. Their application rating (ITE Commercial) and environmental compatibility correspond with the original ISH2412A-TR.

Frequently Asked Questions (FAQ)

Q1: Which key parameters must match when selecting a substitute for ISH2412A-TR?
A1: Essential matching parameters are input voltage range, output voltage and current, output power, isolation voltage, number of outputs, features (SCP or similar), package type, mounting method, and applicable compliance standards.

Q2: Are the substitute parts physically compatible in PCB layout?
A2: Substitute models share the 8-SMD Module, 5 Leads package and very similar dimensions, enabling compatibility within the same PCB footprint and height constraints. Minor differences in width and length are noted in the comparison table.

Q3: Are there differences in mechanical or environmental certifications?
A3: Substitute products include comparable RoHS and MSL status and are approved for ITE (Commercial) applications. Where additional standards (such as EN or CE) are present, these are included in parameter listings.

Q4: What features beyond core electrical performance could affect substitution?
A4: Provided features include SCP (Short-Circuit Protection) and Adjustable Output, aligning with or enhancing the original's protection features.

Q5: Can substitutes be used in all the applications of the original part?
A5: The substitutes are specified for ITE (Commercial) use, matching the application rating of the ISH2412A-TR. Ensure application requirements fall within listed operating temperature and electrical parameters.

Request Quote (Ships tomorrow)